02-17-2009
Nope. we won't be using flash archive
10 More Discussions You Might Find Interesting
1. AIX
hi all,
i have an p620 server. it has 2 scsi 18gb disks for aix4.3 OS and 3 ssa disks for database and an serialRAID adapter. 3 ssa disks configured raid level 5.
to increase capacity of the datavg, i buy 2 ssa 18gb disks. but i can not add them to the existing datavg. i did the following... (1 Reply)
Discussion started by: tinhlx
1 Replies
2. Solaris
I have situation where I want to know about all the vxvm mount points information on my solaris box, because after rebooting the server the few mount points are not mounted automatically because they where not copied in /etc/vfstab.
So please help me out on the same.:( (0 Replies)
Discussion started by: nimish_mehta
0 Replies
3. Solaris
Previously , i remove the disk by
#vxdg -g testdg -k rmdisk testdg02
But i got error when i -k adddisk
bash-2.03# vxdisk list
DEVICE TYPE DISK GROUP STATUS
c0t0d0s2 auto:none - - online invalid
c0t1d0s2 auto:none ... (1 Reply)
Discussion started by: waibabe
1 Replies
4. Solaris
How to find & replace bad disks in solaris & VXVM?plz
explain step by step? (2 Replies)
Discussion started by: xtreams
2 Replies
5. UNIX for Advanced & Expert Users
I have a HP proliant ML 570 G3 with two 146GB disk drives mirrored(RAID1+0)
windows server 2003 was installed on that disk.
I will add a disk.(scsi 300GB)
I will install Linux on that additional disk.
I want to create multiple-boot system.
Is it possible?
I wanna know how to create... (0 Replies)
Discussion started by: lifegeek
0 Replies
6. Solaris
Hi All,
We had a Sun Netra T1 go down the other day, the root disk was mirrored using vxvm. Upon boot from either disk, we had the following error appear:
WARNING: Error writing ufs log state
WARNING: ufs log for / changed state to Error
WARNING: Please umount(1M) / and run... (4 Replies)
Discussion started by: badoshi
4 Replies
7. AIX
Hi,
I would like to know how to find out disk capacity if it is assigned from the storage as a lun.
as per below command , I am unable to find out disk capacity.
$ bash
bash-3.00$ lspv
hdisk1 0001579a7fa3c086 None
$ lscfg -vl hdisk1
hdisk1 ... (8 Replies)
Discussion started by: manoj.solaris
8 Replies
8. Homework & Coursework Questions
Use and complete the template provided. The entire template must be completed. If you don't, your post may be deleted!
I am pretty close I think, but stuck. I don't know how to send an email to the user specified on the command line, and I receive an error stating -ge expecting a unary value(lines... (14 Replies)
Discussion started by: polyglot0727
14 Replies
9. Solaris
Hi,
Can you help me on booting x86 server configured under VxVM. Server boots fine normally from both the disks but if I try to boot server from mirror disk without starting veritas, then it does not boot.
vxplex -g rootdg dis var-02
vxplex -g rootdg dis swapvol-02
vxplex -g rootdg dis... (2 Replies)
Discussion started by: milindphanse604
2 Replies
10. HP-UX
Hello all,
So I made a rookie mistake today. I forgot to remove my disk from my disk group, before running the following command:for i in `ioscan -fnN | awk /NO/'{print $3}'`
do
rmsf -H $i
done
I am trying to run the following command, but not having any luck obviously:vxdg -g dgvol1 rmdisk... (0 Replies)
Discussion started by: mrkejames2
0 Replies
LEARN ABOUT HPUX
vxreattach
vxreattach(1M) vxreattach(1M)
NAME
vxreattach - reattach disk drives that have once again become accessible
SYNOPSIS
/etc/vx/bin/vxreattach [-br ] [accessname...]
/etc/vx/bin/vxreattach -c accessname
DESCRIPTION
The vxreattach utility reattaches disks to the disk group they were in and retains the same media name.
This operation may be necessary if a disk has a transient failure, or if Veritas Volume Manager (VxVM) starts with some disk drivers
unloaded and unloadable. Disks then enter the failed state. If the problem is fixed, vxreattach may be able to reattach the disks without
plexes being flagged as stale, as long as the reattach happens before any volumes on the disk are started.
vxreattach tries to find a disk in the same disk group with the same disk ID for the disk(s) to be reattached. The reattach operation may
fail even after finding the disk with the matching disk ID if the original cause (or some other cause) for the disk failure still exists.
vxreattach is usually invoked by vxdiskadm when performing disk recovery. It is not intended to be run directly by an administrator.
OPTIONS
-b Performs the reattach operation in the background.
-c Checks if a reattach is possible. No operation is performed, but the name of the disk group and disk media name at which the
disk can be reattached is displayed.
-r Tries to recover stale plexes of any volumes on the failed disk. It does this by calling vxrecover.
EXIT CODES
A zero exit status is returned if the reattach is performed; non-zero is returned otherwise.
See vxintro(1M) for a list of standard exit codes.
EXAMPLES
Check if reattachment of disk c1t2d0 is possible:
/etc/vx/bin/vxreattach -c c1t2d0
If reattachment is possible, vxreattach returns with an exit status of 0 and displays the disk group name and disk media name. If reat-
tachment is not possible, vxreattach returns an exit status of 2 and displays an error.
Attempt to reattach the disk in the foreground and try to recover stale plexes of any volumes on the disk:
/etc/vx/bin/vxreattach -r c1t2d0
If the reattachment is successful, vxreattach returns an exit status of 0. Otherwise, if an error occurs, vxreattach returns a non-zero
exit code as defined on vxintro(1M).
FILES
/etc/default/vxplex Standard defaults file that can be used to determine whether FastResync is used when attaching plexes. See vxplex(1M)
for details.
SEE ALSO
vxdiskadm(1M), vxintro(1M), vxplex(1M), vxrecover(1M)
VxVM 5.0.31.1 24 Mar 2008 vxreattach(1M)