Sponsored Content
Full Discussion: Software RAID on Linux
Operating Systems Linux Software RAID on Linux Post 302283095 by mark54g on Monday 2nd of February 2009 02:12:47 PM
Old 02-02-2009
I plan on putting none of the system partitions on the RAID5. Everything system related will be on the 80GB drive, including tmp and swap, but there won't be much of it, maybe 1GB. I don't like the idea of swap on RAID5, but plan on having it on the 80GB for when I get a second drive and mirror.

I keep /tmp separated due to the fact that I dont want a full /tmp to interfere with the root volume. It is how I have always done it and see no need to change to something that may be less resilient, even if it is slightly more convenient.

Also, I believe that the OS can cache the requests until such time as they can get written, and then do a fsync.

If the host controller supports it, the single channel should not have a problem:
FIS(Frame Information Structure)-based switching

FIS-based switching is similar to a USB hub. In this method of switching the host controller can issue commands to send and receive data from any drive at any time. A balancing algorithm ensures a fair allocation of available bandwidth to each drive. FIS-based switching allows the aggregated saturation of the host link and does not interfere with NCQ.

from: Port multiplier - Wikipedia, the free encyclopedia

It turns out, the controller that ships with my enclosure, the Sil3132 supports FIS.
 

9 More Discussions You Might Find Interesting

1. SuSE

Raid software besides Veritass

Hello Lunix people, I am looking for Raid software or solution besides Veritas. Veritas has some great software but are way too costly. Does anyone know of good raid software that but NOT Veritas. I need the funcations but not the cost. (7 Replies)
Discussion started by: xtmeisel
7 Replies

2. UNIX for Advanced & Expert Users

Software RAID ...

Hi all, I m just trying using software RAID in RHEL 4, without problem , then i wanna simulate if disk 1 is fail (thereis an bootloader), i plug off my 1st disk. My problems is the second disk cannot boot? just stuck in grub, the computer is hang. Sorry for poor concept in RAID? I use a RAID 1.... (0 Replies)
Discussion started by: blesets
0 Replies

3. HP-UX

Software RAID (0+1)

Hi! A couple of months ago a disk failed in our JBOD cabinett and I have finally got a new disk to replace it with. It was a RAID 0 so we have to create and configure the whole thing again. First we thought of RAID 1+0 but it seems you can't do this with LVM. If you read my last thread, you can... (0 Replies)
Discussion started by: hoff
0 Replies

4. Red Hat

Software RAID doubt

hi friends, I am having issues with adding a spare device to a failed array. I have created RAID 1 with 3 partitions using mdadm command. Later I added a spare with mdadm --add /dev/md0 /dev/sdb6 This works fine and when I check this with mdadm --detail command it just sits there as a spare... (7 Replies)
Discussion started by: saagar
7 Replies

5. Filesystems, Disks and Memory

Software RAID

Hello, My company has inherited a Centos based machine that has 7 hard drives and a software based raid system. Supposedly one of the drives has failed. I need to replace the hardrive. How can I about telling which hard drive needs replacing? I have looked in the logs and there clearly is a... (5 Replies)
Discussion started by: mojoman
5 Replies

6. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

7. Red Hat

Software RAID configuration

We have configured software based RAID5 with LVM on our RHEL5 servers. Please let us know if its good to configure software RAID on live environment servers. What can be the disadvantages of software RAID against hardware RAID (4 Replies)
Discussion started by: mitchnelson
4 Replies

8. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

9. Solaris

Hardware to software RAID migration

We have hardware RAID configured on our T6320 server and two LDOMs are running on this server. One of our disk got failed and replaced. After replacemnt the newly installed disk not detected by RAID controlled so Oracle suggested to upgrade the REM firmware. As this is the standalone production... (0 Replies)
Discussion started by: rock123
0 Replies
MLXCONTROL(8)						    BSD System Manager's Manual 					     MLXCONTROL(8)

NAME
mlxcontrol -- Mylex DAC-family RAID management utility SYNOPSIS
mlxcontrol <command> [args] mlxcontrol status [-qv] [drive] mlxcontrol rescan controller [controller ...] mlxcontrol detach drive [drive ...] mlxcontrol detach -a mlxcontrol check drive mlxcontrol config controller mlxcontrol help command DESCRIPTION
The mlxcontrol utility provides status monitoring and management functions for devices attached to the mlx(4) driver. Controller names are of the form "mlxN" where N is the unit number of the controller. Drive names are of the form "mlxdN" where N is the unit number of the drive. Do not specify the path to a device node. status Print the status of controllers and system drives. If one or more drives are specified, only print information about these drives, otherwise print information about all controllers and drives in the system. With the -v flag, display much more verbose informa- tion. With the -q flag, do not print any output. This command returns 0 if all drives tested are online, 1 if one or more drives are critical and 2 if one or more are offline. rescan Rescan one or more controllers for non-attached system drives (e.g. drives that have been detached or created subsequent to driver initialisation). If the -a flag is supplied, rescan all controllers in the system. detach Detach one or more system drives. Drives must be unmounted and not opened by any other utility for this command to succeed. If the -a flag is supplied, detach all system drives from the nominated controller. check Initiate a consistency check and repair pass on a redundant system drive (e.g. RAID1 or RAID5). The controller will scan the system drive and repair any inconsistencies. This command returns immediately; use the status command to monitor the progress of the check. rebuild Requires two arguments, controller and physdrive as specified in the output of the status command. All system drives using space on the physical drive physdrive are rebuilt, reconstructing all data on the drive. Note that each controller can only perform one rebuild at a time. This command returns immediately; use the status command to monitor the progress of the rebuild. config Print the current configuration from the nominated controller. This command will be updated to allow addition/deletion of system drives from a configuration in a future release. help Print usage information for command. AUTHORS
The mlxcontrol utility was written by Michael Smith <msmith@FreeBSD.org>. BUGS
The config command does not yet support modifying system drive configuration. Error log extraction is not yet supported. BSD
April 10, 2000 BSD
All times are GMT -4. The time now is 09:45 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.