Hi,
I'm writing a script and have become stuck trying to define a variable (COMP) by adding an elapsed time (ELAPSE e.g 00:55) to a start time (START e.g 23:50).
Can anybody give me a solution as to how I can get a completion time in hh:mm from the variables above?
thanks
Richard (4 Replies)
Is there anyway to get the start time and end time / status of a crontab job which was just completed? Of course, we know the start time of the crontab job since we are scheduling. But I would like to know process start and time recorded somewhere or can be fetched from a command like 'ps'. ... (3 Replies)
Hi,
Can anyone help me how can I get the line that between the start time and end time.
file1.txt
15/03/2009 20:45:03 Request: - Data of this line
15/03/2009 20:45:12 Response: - Data of this line
15/03/2009 22:10:40 Request: - Data of this line
15/03/2009 22:10:42 Response: - Data of... (1 Reply)
Hi All,
Can we get to know the start time and end time of execution of a script? (This script doesn't write any logs.) I mean, is there any built in process logs to track these records? (2 Replies)
Hello All,
I have a problem calculating the time difference between start and end timings...!
the timings are given by 24hr format..
Start Date : 08/05/10 12:55
End Date : 08/09/10 06:50
above values are in mm/dd/yy hh:mm format.
Now the thing is, 7th(08/07/10) and... (16 Replies)
Hi guys,
How can I specify the start and end time of a cron job. And my start time and end time are specified by minutes. For example, I want to set up a cron runs every 3 minutes from 18:40 to midnight. How can i do this please? Many thanks
Best regards,
Clu (4 Replies)
Oracle Enterprise Linux
We want to track how long a process takes to complete its execution. This is what we want in the schell script
Before the process is started , get the time with date, hours and minutes
execute the process
After the process has ended , get the time with date,... (5 Replies)
Hi,
I am trying to remove lines once a string is found till another string is found including the start string and end string. I want to basically grab all the lines starting with color (closing bracket). PS: The line after the closing bracket for color could be anything (currently 'more').... (1 Reply)
Dear team
I am using DB2 and wish to capture the ETL status on daily basis so that i can run the query and share the details in xls format to respective mail ids .
Currently i am using below query but this displays table name and counts for latest run.
select name ,CARD from... (0 Replies)
Discussion started by: Perlbaby
0 Replies
LEARN ABOUT OPENSOLARIS
fatm
FATM(4) BSD Kernel Interfaces Manual FATM(4)NAME
fatm -- device driver for Fore PCA200E ATM interfaces
SYNOPSIS
device fatm
device utopia
device atm
options NATM
DESCRIPTION
The fatm device driver supports the FORE (now Marconi) PCA200E ATM interface cards. The driver interfaces with the natm(4) framework,
netgraph(4) and HARP. It provides only PVC services. Signalling, ATMARP, ILMI and other higher layer protocols are implemented using
netgraph(4) or HARP.
For configuring the card for IP see natmip(4). The following sysctls are recognized by the driver additionally to those handled by
utopia(4):
hw.atm.fatmN.stats
Returns a device specific statistic list of uint32_t statistic counters.
hw.atm.fatmN.istats
Returns a list of uint32_t with internal driver statistics.
hw.atm.fatmN.retry_tx
If this is set packets are stuffed back into the interface's send queue when the cards transmit queue is found to be full. They are
transmitted later. If this is not set the packets are dropped. It may be useful to set this if only UBR traffic is sent.
hw.atm.fatmN.debug
(Only if debugging enabled.) These are debugging flags. See src/sys/dev/fatm/if_fatmvar.h for the possible flags.
The driver supports the media options sdh, noscramb and unassigned (see utopia(4)).
DIAGNOSTICS
fatm0: <FORE PCA200E> mem 0xd5800000-0xd59fffff irq 9 at device 9.0 on pci0
SEE ALSO natm(4), natmip(4), utopia(4)AUTHORS
Harti Brandt <harti@FreeBSD.org>
BUGS
These cards can CBR shape a single VCC only. It is currently possible to request more than one CBR connection. In this case all the timing
will be wrong. See hatm(4) for a better card.
BSD May 15, 2003 BSD