Sponsored Content
Operating Systems Linux kernel: Additional sense: Scsi parity error () Post 302271220 by sbn on Wednesday 24th of December 2008 09:28:53 AM
Old 12-24-2008
kernel: Additional sense: Scsi parity error ()

Hey guys how do you troubleshoot this kind of problem

kernel: Additional sense: Scsi parity error ()
 

9 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

SCSI Tape Error

When I am trying to read any tape I getthe following message on my screen: "stp: Error on SCSI tape=0 (ha=0 id=6 lun=0)" Does anybody know how to solve this problem and what the message means. I already have rebooted the server and cleaned the heads of the tape unit. HELP!!!! (1 Reply)
Discussion started by: Andre
1 Replies

2. Solaris

Sense Key: Media Error

Hi all, We have below WARNING in /var/adm/messages file from our Solaris server. WARNING: /sbus@1f,0/SUNW,fas@e,8800000/sd@0,0 (sd0): Error for Command: write(10) Error Level: Fatal Requested Block: 16745265 Error Block: 16745269 Vendor: SEAGATE Serial Number:... (8 Replies)
Discussion started by: summerboy
8 Replies

3. Solaris

probe-scsi => error

i have a new netra 240 server when i make probe-scsi in obp i have this output : ERROR: /pci@1c,600000: Last Trap: Fast Data Access MMU Miss am upgarading obp firmware but the problem is always here the os solaris 10) is installed correctely and i can use it , when i type #format i can see... (2 Replies)
Discussion started by: lid-j-one
2 Replies

4. Shell Programming and Scripting

Replacing all occurences depending on parity

I want to replace all occurences of '$' in a LaTeX source code in the following way: The dollars on odd position in the file must be changed in '$latex ' and the other dollars can remain the same. I was thinking to make a script which replaces all odd occurences of a given character with a... (4 Replies)
Discussion started by: beni22sof
4 Replies

5. Solaris

Booting from wrong SCSI-disk. Error -256 Stack Underflow

Hi. I need to boot on Sun Blade 150 from scsi-disk, that ran on old Sun Ultra 10. It is necessary to take some the information from an old disk and something to study. The workstation is booted and I receive the following issue::mad: Sun Blade 150 (UltraSPARC-IIe 650MHz), No Keyboard (tip... (3 Replies)
Discussion started by: wolfgang
3 Replies

6. Solaris

solaris raids parity

what actually stored in the parity reserved on each slice in raid 5 configuration. how to restore the data if a disk is failed in raid5 configuration (1 Reply)
Discussion started by: revathireddy
1 Replies

7. Programming

This Makes NO sense. I'm making a game and getting an error, need help.

Okay so I'm making a simple text based game that branches into different scenarios. By branching I mean branching off into whole different files with that part of the game in it. I got tired of working on scenario 1 so I'm working on scenario 2. As I get started and try to test it, I get an error... (1 Reply)
Discussion started by: lemonoid
1 Replies

8. Shell Programming and Scripting

Shell Text Based Game, This Error Makes NO sense. Please help

Okay so I'm making a simple text based game that branches into different scenarios. By branching I mean branching off into whole different files with that part of the game in it. I got tired of working on scenario 1 so I'm working on scenario 2. As I get started and try to test it, I get an... (3 Replies)
Discussion started by: lemonoid
3 Replies

9. AIX

Readcd: Error 0. Cannot open SCSI driver.

i'm trying to burn an DVD ISO into a VIOS virtual optical drive when i try a scanbus i have a failure message : Can u help me please guys ---------- Post updated at 03:38 PM ---------- Previous update was at 12:20 PM ---------- I can't burn in ISO format, so i have to type... (0 Replies)
Discussion started by: Tharsan
0 Replies
GRAID3(8)						    BSD System Manager's Manual 						 GRAID3(8)

NAME
graid3 -- control utility for RAID3 devices SYNOPSIS
graid3 label [-Fhnrvw] [-s blocksize] name prov prov prov ... graid3 clear [-v] prov ... graid3 configure [-adfFhnrRvwW] name graid3 rebuild [-v] name prov graid3 insert [-hv] [-n number] name prov graid3 remove [-v] -n number name graid3 stop [-fv] name ... graid3 list graid3 status graid3 load graid3 unload DESCRIPTION
The graid3 utility is used for RAID3 array configuration. After a device is created, all components are detected and configured automati- cally. All operations such as failure detection, stale component detection, rebuild of stale components, etc. are also done automatically. The graid3 utility uses on-disk metadata (the provider's last sector) to store all needed information. The first argument to graid3 indicates an action to be performed: label Create a RAID3 device. The last given component will contain parity data, whilst the others will all contain regular data. The number of components must be equal to 3, 5, 9, 17, etc. (2^n + 1). Additional options include: -F Do not synchronize after a power failure or system crash. Assumes device is in consistent state. -h Hardcode providers' names in metadata. -n Turn off autosynchronization of stale components. -r Use parity component for reading in round-robin fashion. Without this option the parity component is not used at all for reading operations when the device is in a complete state. With this option specified random I/O read operations are even 40% faster, but sequential reads are slower. One cannot use this option if the -w option is also specified. -s Manually specify array block size. Block size will be set equal to least common multiple of all component's sector sizes and specified value. Note that array sector size calculated as multiple of block size and number of regular data components. Big values may decrease performance and compatibility, as all I/O requests have to be multiple of sector size. -w Use verify reading feature. When reading from a device in a complete state, also read data from the parity component and ver- ify the data by comparing XORed regular data with parity data. If verification fails, an EIO error is returned and the value of the kern.geom.raid3.stat.parity_mismatch sysctl is increased. One cannot use this option if the -r option is also speci- fied. clear Clear metadata on the given providers. configure Configure the given device. Additional options include: -a Turn on autosynchronization of stale components. -d Do not hardcode providers' names in metadata. -f Synchronize device after a power failure or system crash. -F Do not synchronize after a power failure or system crash. Assumes device is in consistent state. -h Hardcode providers' names in metadata. -n Turn off autosynchronization of stale components. -r Turn on round-robin reading. -R Turn off round-robin reading. -w Turn on verify reading. -W Turn off verify reading. rebuild Rebuild the given component forcibly. If autosynchronization was not turned off for the given device, this command should be unnecessary. insert Add the given component to the existing array, if one of the components was removed previously with the remove command or if one component is missing and will not be connected again. If no number is given, new component will be added instead of first missed component. Additional options include: -h Hardcode providers' names in metadata. remove Remove the given component from the given array and clear metadata on it. stop Stop the given arrays. Additional options include: -f Stop the given array even if it is opened. list See geom(8). status See geom(8). load See geom(8). unload See geom(8). Additional options include: -v Be more verbose. EXIT STATUS
Exit status is 0 on success, and 1 if the command fails. EXAMPLES
Use 3 disks to setup a RAID3 array (with the round-robin reading feature). Create a file system, mount it, then unmount it and stop device: graid3 label -v -r data da0 da1 da2 newfs /dev/raid3/data mount /dev/raid3/data /mnt ... umount /mnt graid3 stop data graid3 unload Create a RAID3 array, but do not use the automatic synchronization feature. Rebuild parity component: graid3 label -n data da0 da1 da2 graid3 rebuild data da2 Replace one data disk with a brand new one: graid3 remove -n 0 data graid3 insert -n 0 data da5 SEE ALSO
geom(4), geom(8), gvinum(8), mount(8), newfs(8), umount(8) HISTORY
The graid3 utility appeared in FreeBSD 5.3. AUTHORS
Pawel Jakub Dawidek <pjd@FreeBSD.org> BUGS
There should be a section with an implementation description. Documentation for sysctls kern.geom.raid3.* is missing. BSD
January 15, 2012 BSD
All times are GMT -4. The time now is 08:32 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy