I get a transaction file and I need to sum two of the columns. I each record I get a debit(D) or credit(C) indicator. Then I get an amount field. I need to sum the total dollar value of debits and credits.
I know I can loop through each record and get the sum total but is there a better way with... (7 Replies)
Hi Friends
How to do sum on a column?
I have a file like:
FRED 500.01 TX
SMITH 50.10 NY
HARRY 5.00 CA
555.11
Sum on second column.
I am trying using nawk like
nawk 'BEGIN {FS="|"}; {printf $1"+"}'
Thanks a lot for your help
S :) (2 Replies)
Hi,
I am exporting data from a table with 4 columns into a file. The 4th column contains amount which is decimal(11,2) with values ranging from 0.00 to 999999999.99. I need to mail this file to the users but before doing that i need to format the amount column as 999,999.00 instead of 999999.00... (4 Replies)
Hi, all:
I've got two folders, say, "folder1" and "folder2".
Under each, there are thousands of files.
It's quite obvious that there are some files missing in each. I just would like to find them. I believe this can be done by "diff" command.
However, if I change the above question a... (1 Reply)
Suppose I have a XSD definition of amount:
<xs:element name="Amount" type="amount>
And the amounts themselves are given in the following format in the XML:
<amount>1.000.00</amount>
In other words, the thousand separator and the decimal point are the same.
Does this require that the parser... (3 Replies)
All, I've searched and haven't found a solution for my particular issue.
I have a file with lines of data that contain varying amounts of underscores imbedded. But all the strings have a final underscore and an interface name:
dmk_hcn_dalian2.XXXX.XXX.XX.COM_Se0/0/0... (4 Replies)
Discussion started by: turk22
4 Replies
LEARN ABOUT HPUX
u3b5
machid(1) General Commands Manual machid(1)NAME
machid: hp9000s200, hp9000s300, hp9000s400, hp9000s500, hp9000s700, hp9000s800, hp-mc680x0, hp-pa, pdp11, u370, u3b, u3b10, u3b2, u3b5, vax
- provide truth value about processor type
SYNOPSIS DESCRIPTION
The following commands return a true value (exit code 0) if the a processor type matches the command name. Otherwise a false value (exit
code nonzero) is returned. These commands are commonly used within makefiles and shell procedures to improve portability of applications
(see make(1)).
+-----------+-------------------------++--------+--------------------------+
|Command | True for ||Command | True for |
+-----------+-------------------------++--------+--------------------------+
|hp9000s200 | Series 200 ||pdp11 | PDP-11/45 or PDP-11/70 |
|hp9000s300 | Series 300 ||u3b | 3B20 computer |
|hp9000s400 | Series 400 ||u3b2 | 3B2 computer |
|hp9000s500 | Series 500 ||u3b5 | 3B5 computer |
|hp9000s700 | Series 700 ||u3b10 | 3B10 computer |
|hp9000s800 | Series 800 or 700 ||u370 | IBM System/370 computer |
|hp-mc680x0 | Series 200, 300, or 400 ||vax | VAX-11/750 or VAX-11/780 |
|hp-pa | Series 700 or 800 || | |
+-----------+-------------------------++--------+--------------------------+
EXAMPLES
Given a shell script that must behave differently when run on an HP 9000 Series 700 or 800 system, select the correct code segment to be
executed:
WARNINGS
always returns true on both Series 800 and Series 700 systems. Therefore, when using this command in scripts to determine hardware type,
always use both and in the appropriate sequence to ensure correct results (see
machid(1) will no longer provide support for future machines beyond the Series 800 and Series 700 systems. Decisions should be based on
the hardware and software configuration information returned by getconf(1).
SEE ALSO getconf(1), make(1), sh(1), test(1), true(1).
machid(1)