Sponsored Content
Special Forums Hardware Filesystems, Disks and Memory What should I do with this metastat result? metareplace everything? Post 302269083 by nickychung on Tuesday 16th of December 2008 09:06:16 PM
Old 12-16-2008
There is no increase of hard error.
Format can not recognize c0t0d0.

And, metareplace -e d0 c0t0d0s0 returns I/O errors.

Is it possible to bring mirror d0 back online with c0t1d0s0?

metastat -p returns

Quote:
d0 -m d10 d20 1
d10 1 1 c0t0d0s0
d20 1 1 c0t1d0s0
d1 -m d11 d21 1
d11 1 1 c0t0d0s1
d21 1 1 c0t1d0s1
d6 -m d16 1
d16 1 1 c0t0d0s6
d7 -m d17 d27 1
d17 1 1 c0t0d0s7
d27 1 1 c0t1d0s7
d26 1 1 c0t1d0s6
 

10 More Discussions You Might Find Interesting

1. Solaris

SVM metastat -- needs maintenance

Running Solaris 9 with SVM. I'm not that familiar with it, but metastat output gives "needs maintenance" message on 2 of the mirrors. There are no errors in /var/adm/messages. What do I need to do to fix this error? Thanks. (14 Replies)
Discussion started by: dangral
14 Replies

2. Solaris

Help on metastat

hi all, can someone pls pass on your suggestion? Firs thing I am testing a script which checks for the pattern 'Needs Maintenance' from metastat output and prints some messages in the screen. So i need to simulate an error in mirrored disk for metastat to give this message 'Needs Maintenance'.... (3 Replies)
Discussion started by: srirammad007
3 Replies

3. Solaris

metareplace error

Hello guys, i am getting some errors as below when i want to perform maintainence on the disks of my servers, getting errors like this "metareplace: myhost: /dev/dsk/c1t0d0s5: Invalid argument" when i execute #metareplace -e d5 c1t0d0s5 kindly advise on this matter,am afraid to use -f... (4 Replies)
Discussion started by: cromohawk
4 Replies

4. Solaris

SVM - metastat - Last Erred

My company is running a solaris 2.7 machine. The machine is getting slow recently. I have no expert in solaris. Please help. I checked the log in /var/adm/message: I also checked with the command iostat -nE. It returns: Metastat returns the followings: What should i do now?... (10 Replies)
Discussion started by: nickychung
10 Replies

5. Solaris

Urgent- metareplace -e write errors

I have a disk in maintanance status . I executed metareplace -e partition device . It resynced upto 5 % and then stopped . In the /var/adm/messages it showed the write error . My question is if I analyse and repair the disk in format command , will my write error go . I dont have 0 hard and... (6 Replies)
Discussion started by: Hitesh Shah
6 Replies

6. Solaris

Softpartition State: Errored in Command MetaStat

Hi people, I have on problem when execute the command METASTAT... d60: Soft Partition Device: d10 State: Errored Size: 12582912 blocks (6.0 GB) Someone help me? Thank you very much (4 Replies)
Discussion started by: denisgomes
4 Replies

7. Shell Programming and Scripting

Grep contents from metastat command

Hi, after issuing metastat command I am getting output as follows Actually these soft partitions are more than 100. I want output as Device Name & Size. for eg d4004 2.0 GB (4 Replies)
Discussion started by: tuxian
4 Replies

8. Solaris

DiskSuite State Unavailable After metareplace

Hello, After replacing a JBOD disk that died, the metareplace was ran, the device went into enable/sync'ing state and then when the sync completed, the state changed to unavailable. metadb shows the replica db looking good on the new disk. format shows the disk online and looking good. ... (2 Replies)
Discussion started by: rfransix
2 Replies

9. Solaris

metastat |grep Needs

Dear, Required an script such that : If metastat |grep Needs , results in some output then this command to be executed for the same : opcmsg object=metastat a=OS msg_grp=OpC severity=critical msg_text="Need maintenance for the system $line" With regards, Mjoshi (3 Replies)
Discussion started by: mjoshi87
3 Replies

10. Solaris

Metastat shows state needs maintenance

Hi, We have a Solaris 10 machine with update 11 and was configured with IBM storage. It was assigned 2 LUNs (each 70GB) which were striped to make it 140GB. we have taken full backup of entire machine and Our storage team replaced IBM storage with Nimble storage (they did storage-level... (6 Replies)
Discussion started by: prvnrk
6 Replies
metarename(1M)						  System Administration Commands					    metarename(1M)

NAME
metarename - rename metadevice or switch layered metadevice names SYNOPSIS
/usr/sbin/metarename [-s setname] metadevice1 metadevice2 /usr/sbin/metarename [-s setname] [-f] -x metadevice1 metadevice2 /usr/sbin/metarename -h DESCRIPTION
There are two ways to use metarename, one with and one without the -x option. The first method (without -x) renames an existing metadevice to a new name. This makes managing the metadevice namespace easier. The metadevice being renamed cannot be mounted or open, nor can the new name already exist. For example, to rename a metadevice that contains a mounted file system, you would first need to unmount the file sys- tem. With the second way to use metarename, using the -x option, metarename switches (exchanges) the names of an existing layered metadevice and one of its subdevices. In Solaris Volume Manager terms, a layered metadevice can be either a mirror or a trans metadevice. The -x option enables you to switch the metadevice names of a mirror and one of its submirrors, or a trans metadevice and its master device. metarename -x makes it easier to mirror or unmirror an existing stripe or concatenation, and to remove a trans device. When used to mirror an existing stripe or concatenatation, you must stop access to the device. For example, if the device contains a mounted file system, you must first unmount the file system before doing the rename. You can also use the metarename -x command to untrans a trans metadevice from an existing device. This applies only to the master device. You cannot remove a logging device with metarename. Before you can rename a trans device, you must detach the logging device. Then you must stop access to the trans metadevice itself. You cannot rename or switch metadevices that are in an error state or that have subcomponents in an error state, or metadevices actively using a hot spare replacement. You can only switch metadevices that have a direct child/parent relationship. You could not, for example, directly exchange a stripe in a mirror that is a master device with the trans metadevice. You must use the -f flag when switching members of a trans metadevice. Only metadevices can be switched, not slices. OPTIONS
The following options are supported: -f Force the switching of trans metadevice members. -h Display a help message. -s setname Specifies the name of the diskset on which metarename will work. Using the -s option will cause the command to perform its administra- tive function within the specified diskset. Without this option, the command will perform its function on the local metadevices. -x Exchange the metadevice names metadevice1 and metadevice2. metadevice1 Specifies the metadevice to be renamed or switched. metadevice2 Specifies the target metadevice name for the rename or switch operation. EXAMPLES
Example 1: Renaming a Metadevice This example renames a metadevice named d10 to d100. Note that d100 must not exist for the rename to succeed. # metarename d10 d100 Example 2: Creating a Two-Way Mirror This example creates a two-way mirror from an existing stripe named d1 with a mounted file system, /home2. # metainit d2 1 1 c13d0s1 # metainit -f d20 -m d1 # umount /home2 # metarename -x d20 d1 # metattach d1 d2 # mount /home2 First, a second concatenation d2, is created. (d1 already exists.) The metainit command creates a one-way mirror, d20, from d1. Next, you umount the file system and switch d1 for d20, making d1 the top-level device (mirror). You attach the second submirror, d2, to create a two-way mirror. Lastly, you remount the file system. Example 3: Mounting a Mirrored File System on Stripe This example takes an existing mirror named d1 with a mounted file system, and ends up with the file system mounted on a stripe d1. # umount /fs2 # metarename -x d1 d20 # metadetach d20 d1 # metaclear -r d20 # mount /fs2 First, you unmount the file system, then switch the mirror d1 and its submirror d20. This makes the mirror into d20. Next, you detach d1 from d20, then delete the mirror d20 and its other submirror. You then remount the file system. Example 4: Deleting a Trans Metadevice This example deletes a trans metadevice named d10 while its mount point is /myhome. The master device, which is a stripe, is named d2. The logging device, also a stripe, is named d5. # umount /myhome # metadetach d10 # metarename -f -x d10 d2 # metaclear d2 # metaclear d5 # fsck /dev/md/dsk/d10 # mount /myhome You umount the file system first, then detach the trans metadevice's logging device. The trans metadevice is switched with the master device, making the trans metadevice d2 and the underlying stripe d10. You clear the trans metadevice d2 and the logging device d5. d10 must be fsck'd, and then the file system is remounted. EXIT STATUS
The following exit values are returned: 0 Successful completion. >0 An error occurred. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWmdu | +-----------------------------+-----------------------------+ SEE ALSO
mdmonitord(1M), metaclear(1M), metadb(1M), metadetach(1M), metahs(1M), metainit(1M), metaoffline(1M), metaonline(1M), metaparam(1M), metarecover(1M), metareplace(1M), metaroot(1M), metaset(1M), metassist(1M), metastat(1M), metasync(1M), metattach(1M), md.tab(4), md.cf(4), mddb.cf(4), md.tab(4), attributes(5), md(7D) Solaris Volume Manager Administration Guide LIMITATIONS
Renaming and exchanging metadevice names can only be used for metadevices. A physical slice cannot be renamed to a metadevice, nor can a metadevice be exchanged with a physical slice name. Metadevice names are strings of the pattern d<xyz> where xyz is a value between 0 and 8192. You cannot use logical names for metadevices. NOTES
Trans metadevices have been replaced by UFS logging. Existing trans devices are not logging--they pass data directly through to the under- lying device. See mount_ufs(1M) for more information about UFS logging. SunOS 5.10 8 Aug 2003 metarename(1M)
All times are GMT -4. The time now is 10:22 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy