Sponsored Content
Operating Systems Solaris sun 8 unable to communicate through console Post 302265889 by TonyFullerMalv on Monday 8th of December 2008 05:21:14 PM
Old 12-08-2008
If you can access your E450 over the network run:
$ eeprom | grep device
and ensure that input-device and output-device are set to ttya, or if you are using the serial port of a remote admin. (ILOM) card they may be set to rsc, they may be set to keyboard and display respectively if your server has a frame buffer (graphics card) in which the serial port will not be the console.
 

9 More Discussions You Might Find Interesting

1. Solaris

Hooking up to Console's on sun's

it there any docs out there anyhwre that have the specs for cabing to a sun console. I have an e420 here, i cant seem to get a console connection, i have triewd the silver serial connectors that come with the new dsun servers, but no luck with those. (1 Reply)
Discussion started by: BG_JrAdmin
1 Replies

2. HP-UX

Unable to login at console and telnet

Hi friend, I'm facing a problem to access the console and telnet to the HP ux 11 server due to the system file is full. How to access this server via single mode and how to mount the folder / and folder /var? thanks. vestro (1 Reply)
Discussion started by: vestro
1 Replies

3. Red Hat

unable to communicate with Linux machine

Hi all, I installed red hat 2.6.9-5 and when I am trying to ping it.I am able to ping any other machine in the network but unable to do vice-versa(means unable to ping this machine from any other machine) and getting the message -- please provide your valuable suggestions ... (2 Replies)
Discussion started by: smartgupta
2 Replies

4. Infrastructure Monitoring

unable to load console info in SUNMC 4.0

hi all, unable to load console info in SUNMC 4.0 in alarm it is giving error info i.e..Agent on host (.....),1161 port not responding. plz try to solve the problem Regards spandhan (5 Replies)
Discussion started by: spandhan
5 Replies

5. Solaris

unable to load console info in SUNMC 4.0

Hi all, unable to load console info in SUNMC 4.0 in alarm it is giving error info i.e..Agent on host (.....),1161 port not responding. Iam using M9000 server solaris 10 plz try to solve the problem Regards spandhan (0 Replies)
Discussion started by: spandhan
0 Replies

6. Solaris

Sun Fire V890 - Unable to access RSC or Serial console

Hello Folks, I am having trouble to login to rsc or serial console of V890. The rsc2.2.3 has been configured with required parameters, resetrs and even rebooted. When serial port is connected to laptop, The hyper terminal does not get the console or POSt messages when the server is rebooting... (8 Replies)
Discussion started by: defflepord
8 Replies

7. AIX

P550 Unable to access Console

I have recently aquired the following machine: IBM,9113-550 Up until yesterday we could connect a dumb terminal to serial port 1 and get console login. However the dumb terminal died. We are now using a laptop with a null modem cable attached to serial port 1. This works perfectly for all of... (1 Reply)
Discussion started by: rsw7724
1 Replies

8. Solaris

Unable to take console

When trying to connect to console, I am getting the below error. plathwsvcd: Another instance is running. plathwsvcd: Another instance is running. plathwsvcd: Another instance is running. plathwsvcd: Another instance is running. INIT: Id "plhw" respawning too fast: disabled for 5 minutes ... (3 Replies)
Discussion started by: aksijain
3 Replies

9. Solaris

Unable to start webconsole:console

Here is issue... bash-3.00# svcs system/webconsole:console STATE STIME FMRI maintenance 1:15:54 svc:/system/webconsole:console bash-3.00# svcadm clear svc:/system/webconsole:console bash-3.00# svcs -a |grep /system/webconsole offline* 1:20:44... (0 Replies)
Discussion started by: lingeshwaran
0 Replies
scc(7)							 Miscellaneous Information Manual						    scc(7)

NAME
scc - Serial keyboard/mouse/communications interface SYNOPSIS
controller scc0 at tc0 slot 3 vector sccintr DESCRIPTION
Two base board Zilog scc dual UARTS provide DEC 3000 series personal systems with keyboard, mouse, and serial communications interfaces. The serial communications interfaces can operate at baud rates from B50 to B57600 (see tty(7)). The driver for the scc interface supports hardware flow control using the Request to Send (RTS) and Clear to Send (CTS) signals. When hardware flow control is enabled, the flow of input data is controlled by the RTS signal and the flow of output data is controlled by the CTS signal. If the CTS signal is off, the driver will suspend output to that line until the CTS lead is reasserted. Likewise, the driver will turn off the RTS lead to tell the device connected to the line to stop sending data as a result of congestion on the host side. When the condition clears, the driver will turn on the RTS lead to tell the device to resume sending data. In alternate console configurations (that is, no graphics head), communications port 2 (/dev/tty01) becomes the system console. The serial system console port always operates at 9600 BPS, 8-bits, no parity. No modem or hardware flow control is supported. RESTRICTIONS
Data communications equipment attached to the console serial port in alternate console configurations must be set to 9600 BPS, 8-bits, no parity. The scc driver enforces this restriction. Only communications port 1 (/dev/tty00) includes full modem control. FILES
console terminal local terminal local terminal RELATED INFORMATION
console(7), devio(7), modem(7), tty(7), MAKEDEV(8) delim off scc(7)