Quote:
Originally Posted by reborg
Is you disk partitioned? If not it needs to be partitioned first.

Is that d5 a submirror? If not, use the submirror.
You should use the mirror right? why sub-mirror? Smilie
#metareplace -e <mirror> <component>
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Error: Internal system error: Unable to initialize standard output file

Hey guys, need some help. Running AIX Version 5.2 and one of our cron jobs is writing errors to a log file. Any ideas on the following error message. Error: Internal system error: Unable to initialize standard output file I'm guessing more info might be needed, so let me know. Thanks (2 Replies)
Discussion started by: firkus
2 Replies

2. UNIX for Dummies Questions & Answers

awk Shell Script error : "Syntax Error : `Split' unexpected

hi there i write one awk script file in shell programing the code is related to dd/mm/yy to month, day year format but i get an error please can anybody help me out in this problem ?????? i give my code here including error awk ` # date-month -- convert mm/dd/yy to month day,... (2 Replies)
Discussion started by: Herry
2 Replies

3. UNIX for Advanced & Expert Users

VSI-FAX error - Cannot login to server and Connecto error to host

I encounters a VSIFAX related error: vfxstat: Cannot login to server on rsac3: Connect error to host 172.16.1.45: Invalid argument It started happening last night with a core dump. Then we can't start VSIFAX again. I am runing VSI-FAX 4.2 on AIX box (0 Replies)
Discussion started by: b_jin
0 Replies

4. AIX

nim mksysb error :/usr/bin/savevg[33]: 1016,07: syntax error

-------------------------------------------------------------------------------- Hello, help me please. I am trying to create a mksysb bakup using nim. I am geting this error, how to correct it ? : Command : failed stdout: yes stderr: no... (9 Replies)
Discussion started by: astjen
9 Replies

5. Filesystems, Disks and Memory

What should I do with this metastat result? metareplace everything?

I have to rescue the volumes in a soloris 7 machine. The metastat returns the following result: d6 is dying with iostat -nE returns Harderror 3, Transports error 9 Can some offer me some help? Thank you very much. (6 Replies)
Discussion started by: nickychung
6 Replies

6. Solaris

Urgent- metareplace -e write errors

I have a disk in maintanance status . I executed metareplace -e partition device . It resynced upto 5 % and then stopped . In the /var/adm/messages it showed the write error . My question is if I analyse and repair the disk in format command , will my write error go . I dont have 0 hard and... (6 Replies)
Discussion started by: Hitesh Shah
6 Replies

7. Solaris

DiskSuite State Unavailable After metareplace

Hello, After replacing a JBOD disk that died, the metareplace was ran, the device went into enable/sync'ing state and then when the sync completed, the state changed to unavailable. metadb shows the replica db looking good on the new disk. format shows the disk online and looking good. ... (2 Replies)
Discussion started by: rfransix
2 Replies

8. UNIX for Dummies Questions & Answers

> 5 ")syntax error: operand expected (error token is " error

im kinda new to shell scripting so i need some help i try to run this script and get the error code > 5 ")syntax error: operand expected (error token is " the code for the script is #!/bin/sh # # script to see if the given value is correct # # Define errors ER_AF=86 # Var is... (4 Replies)
Discussion started by: metal005
4 Replies

9. Solaris

Rpcinfo: can't contact portmapper: RPC: Authentication error; why = Failed (unspecified error)

I have two servers with a fresh install of Solaris 11, and having problems when doing rpcinfo between them. There is no firewall involved, so everything should theoretically be getting through. Does anyone have any ideas? I did a lot of Google searches, and haven't found a working solution yet. ... (2 Replies)
Discussion started by: christr
2 Replies

10. UNIX for Beginners Questions & Answers

Print Error in Console and both Error & Output in Log file - UNIX

I am writing a shell script with 2 run time arguments. During the execution if i got any error, then it needs to redirected to a error file and in console. Also both error and output to be redirected to a log file. But i am facing the below error. #! /bin/sh errExit () { errMsg=`cat... (1 Reply)
Discussion started by: sarathy_a35
1 Replies
scdpm(1M)						  System Administration Commands						 scdpm(1M)

NAME
scdpm - manage disk path monitoring daemon SYNOPSIS
scdpm [-a] {node | all} scdpm -f filename scdpm -m {[node | all][:/dev/did/rdsk/]dN | [:/dev/rdsk/]cNtXdY | all} scdpm -n {node | all} scdpm -p [-F] {[node | all][:/dev/did/rdsk/]dN | [/dev/rdsk/]cNtXdY | all} scdpm -u {[node | all][:/dev/did/rdsk/]dN | [/dev/rdsk/]cNtXdY | all} DESCRIPTION
Note - Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor- mation about the object-oriented command set, see the Intro(1CL) man page. The scdpm command manages the disk path monitoring daemon in a cluster. You use this command to monitor and unmonitor disk paths. You can also use this command to display the status of disk paths or nodes. All of the accessible disk paths in the cluster or on a specific node are printed on the standard output. You must run this command on a cluster node that is online and in cluster mode. You can specify either a global disk name or a UNIX path name when you monitor a new disk path. Additionally, you can force the daemon to reread the entire disk configuration. You can use this command only in the global zone. OPTIONS
The following options are supported: -a Enables the automatic rebooting of a node when all monitored disk paths fail, provided that the following conditions are met: o All monitored disk paths on the node fail. o At least one of the disks is accessible from a different node in the cluster. You can use this option only in the global zone. Rebooting the node restarts all resource and device groups that are mastered on that node on another node. If all monitored disk paths on a node remain inaccessible after the node automatically reboots, the node does not automatically reboot again. However, if any monitored disk paths become available after the node reboots but then all monitored disk paths again fail, the node automatically reboots again. You need solaris.cluster.device.admin role-based access control (RBAC) authorization to use this option. See rbac(5). -F If you specify the -F option with the -p option, scdpm also prints the faulty disk paths in the cluster. The -p option prints the cur- rent status of a node or a specified disk path from all the nodes that are attached to the storage. -f filename Reads a list of disk paths to monitor or unmonitor in filename. You can use this option only in the global zone. The following example shows the contents of filename. u schost-1:/dev/did/rdsk/d5 m schost-2:all Each line in the file must specify whether to monitor or unmonitor the disk path, the node name, and the disk path name. You specify the m option for monitor and the u option for unmonitor. You must insert a space between the command and the node name. You must also insert a colon (:) between the node name and the disk path name. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -m Monitors the new disk path that is specified by node:diskpath. You can use this option only in the global zone. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -n Disables the automatic rebooting of a node when all monitored disk paths fail. You can use this option only in the global zone. If all monitored disk paths on the node fail, the node is not rebooted. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -p Prints the current status of a node or a specified disk path from all the nodes that are attached to the storage. You can use this option only in the global zone. If you also specify the -F option, scdpm prints the faulty disk paths in the cluster. Valid status values for a disk path are Ok, Fail, Unmonitored, or Unknown. The valid status value for a node is Reboot_on_disk_failure. See the description of the -a and the -n options for more information about the Reboot_on_disk_failure status. You need solaris.cluster.device.read RBAC authorization to use this option. See rbac(5). -u Unmonitors a disk path. The daemon on each node stops monitoring the specified path. You can use this option only in the global zone. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). EXAMPLES
Example 1 Monitoring All Disk Paths in the Cluster Infrastructure The following command forces the daemon to monitor all disk paths in the cluster infrastructure. # scdpm -m all Example 2 Monitoring a New Disk Path The following command monitors a new disk path.All nodes monitor /dev/did/dsk/d3 where this path is valid. # scdpm -m /dev/did/dsk/d3 Example 3 Monitoring New Disk Paths on a Single Node The following command monitors new paths on a single node. The daemon on the schost-2 node monitors paths to the /dev/did/dsk/d4 and /dev/did/dsk/d5 disks. # scdpm -m schost-2:d4 -m schost-2:d5 Example 4 Printing All Disk Paths and Their Status The following command prints all disk paths in the cluster and their status. # scdpm -p schost-1:reboot_on_disk_failure enabled schost-2:reboot_on_disk_failure disabled schost-1:/dev/did/dsk/d4 Ok schost-1:/dev/did/dsk/d3 Ok schost-2:/dev/did/dsk/d4 Fail schost-2:/dev/did/dsk/d3 Ok schost-2:/dev/did/dsk/d5 Unmonitored schost-2:/dev/did/dsk/d6 Ok Example 5 Printing All Failed Disk Paths The following command prints all of the failed disk paths on the schost-2 node. # scdpm -p -F all schost-2:/dev/did/dsk/d4 Fail Example 6 Printing the Status of All Disk Paths From a Single Node The following command prints the disk path and the status of all disks that are monitored on the schost-2 node. # scdpm -p schost-2:all schost-2:reboot_on_disk_failure disabled schost-2:/dev/did/dsk/d4 Fail schost-2:/dev/did/dsk/d3 Ok EXIT STATUS
The following exit values are returned: 0 The command completed successfully. 1 The command failed completely. 2 The command failed partially. Note - The disk path is represented by a node name and a disk name. The node name must be the host name or all. The disk name must be the global disk name, a UNIX path name, or all. The disk name can be either the full global path name or the disk name: /dev/did/dsk/d3 or d3. The disk name can also be the full UNIX path name: /dev/rdsk/c0t0d0s0. Disk path status changes are logged with the syslogd LOG_INFO facility level. All failures are logged with the LOG_ERR facility level. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWsczu | +-----------------------------+-----------------------------+ |Stability |Evolving | +-----------------------------+-----------------------------+ SEE ALSO
Intro(1CL), cldevice(1CL), clnode(1CL), attributes(5) Sun Cluster System Administration Guide for Solaris OS Sun Cluster 3.2 22 Jun 2006 scdpm(1M)
All times are GMT -4. The time now is 03:53 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy