11-28-2008
Thanks chirs..!!
Great...
10 More Discussions You Might Find Interesting
1. AIX
Hello,
I have two systems that are being prepared to be SAN attached ..
can anyone tell me any specific checks I should perform prior to the cards being installed...
I am aware of firmware / OS level and relevant drivers, is there anything else?
thanks
Chris. (8 Replies)
Discussion started by: chlawren
8 Replies
2. AIX
Hello,
Searched in all IBM Redbooks and on the internet and couldn't find anything about the new feature of POWER 6 which Virtual Fibre ( Fiber ) channel adapter.
It is similar to virtual scsi adapter.
In my client partition I created the virtual Fibre Adapter mapped it with the VIO... (1 Reply)
Discussion started by: filosophizer
1 Replies
3. Shell Programming and Scripting
I have a file with the following data. I want to start writing lines out of this file to another file only after the time is greater than 20:00:00 hours and the first job is U1KC000. I would like to be able to run this out of a script and pass the time and job(U1KC000) as an argument.
... (14 Replies)
Discussion started by: wawa
14 Replies
4. Shell Programming and Scripting
dear all,
i want elimination file with disk space for example:
$ df -h
Filesystem Size Used Avail Use% Mounted on
/dev/mapper/VolGroup00-LogVol00
62G 19G 41G 31% /
/dev/sda1 99M 13M 82M 13% /boot
tmpfs 1014M 0... (2 Replies)
Discussion started by: zvtral
2 Replies
5. Shell Programming and Scripting
hi,
my input
a b c d e f g
k i m g i k l
b i n g o h m
a b c d e
b i n g o
my output
a b c d e f g
k i m g i k l
b i n g o h m
what I would like to do is compare the first five columns of each row to the entire records in the file and if there is a match, eliminate that... (1 Reply)
Discussion started by: jacobs.smith
1 Replies
6. Hardware
We will be buying new Xeon E5-based servers for our datacenter and were wondering which Fibre Channel host bus adapters we should select for these. The choices are Emulex or QLogic (8Gb FC HBAs). Anybody have any recommendations on which is the better choice?
Thanks in advance. (1 Reply)
Discussion started by: atahmass
1 Replies
7. War Stories
Hi Folks,
A couple of years ago we had to replace the core switches between two of our data centres, a simple task for the most part - these new switches would be state of the art Cisco Catalyst units.
The link between the two sites was a dark fibre, with 8Gb bandwidth running full duplex... (9 Replies)
Discussion started by: gull04
9 Replies
8. AIX
Hi guys,
I've been trying to tackle this issue for days and I'm stumped. Hopefully someone can give more light on what else I can do.
I have a p7 series box, with dual VIOS and 10 lpars and everything was working fine until I had to move the box to another location in the data centre. Ensured... (16 Replies)
Discussion started by: aixkidbee
16 Replies
9. IP Networking
Hello,
Please note that we have squid and running properly on ADSL connection. We have upgraded the link to connect through our Fibre switch with a public static IP.
How do we configure squid to connect through this static ip? Note when we connect it directly from fibre switch to our laptop -... (0 Replies)
Discussion started by: isoabv
0 Replies
10. AIX
Hello all,
Let me introduce about the context and my environment.
We have an AIX 6.1 system, it has 4 FC channels
/ > lsdev -Cc adapter | grep fcs
fcs0 Available 23-T1 Virtual Fibre Channel Client Adapter
fcs1 Available 23-T1 Virtual Fibre Channel Client Adapter
fcs2 Available 23-T1... (14 Replies)
Discussion started by: Phat
14 Replies
fp(7d) Devices fp(7d)
NAME
fp - Sun Fibre Channel port driver
DESCRIPTION
The fp driver is a Sun fibre channel nexus driver that enables fibre channel topology discovery, device discovery, fibre channel adapter
port management and other capabilities through well-defined fibre channel adapter driver interfaces.
The fp driver requires the presence of a fabric name server in fabric and public loop topologies to discover fibre channel devices. In pri-
vate loop topologies, the driver discovers devices by performing PLOGI to all valid AL_PAs, provided that devices do not participate in
LIRP and LILP stages of loop initialization.
CONFIGURATION
The fp driver is configured by defining properties in the fp.conf file. The fp driver supports the following properties:
mpxio-disable
Solaris I/O multipathing is enabled or disabled on fibre channel devices with the mpxio-disable property. Specifying mpxio-disable="no"
activates I/O multipathing, while mpxio-disable="yes" disables the feature.
Solaris I/O multipathing may be enabled or disabled on a per port basis. Per port settings override the global setting for the specified
ports. The following example shows how to disable multipathing on port 0 whose parent is /pci@8,600000/SUNW,qlc@4:
name="fp" parent="/pci@8,600000/SUNW,qlc@4" port=0
mpxio-disable="yes";
manual_configuration_only
Automatic configuration of SCSI devices in the fabric is enabled by default and thus allows all devices discovered in the SAN zone to be
enumerated in the kernel's device tree automatically. The manual_configuration_only property may be configured to disable the default
behavior and force the manual configuration of the devices in the SAN. Specifying manual_configuration_only=1 disables the automatic con-
figuration of devices.
FILES
/kernel/drv/fp
32-bit ELF kernel driver (x86)
/kernel/drv/amd64/fp
64-bit ELF kernel driver (x86)
/kernel/drv/sparcv9/fp
64-bit ELF kernel driver (SPARC)
/kernel/drv/fp.conf
fp driver configuration file.
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|mpxio-disable |Unstable |
+-----------------------------+-----------------------------+
|manual_configuration_only |Obsolete |
+-----------------------------+-----------------------------+
|Availability |SUNWfctl |
+-----------------------------+-----------------------------+
SEE ALSO
cfgadm_fp(1M), prtconf(1M), stmsboot(1M), driver.conf(4), attributes(5), fcp(7D), fctl(7D), scsi_vhci(7D)
Writing Device Drivers
Fibre Channel Physical and Signaling Interface (FC-PH) ANSI X3.230: 1994
Fibre Channel Generic Services (FC-GS-2) Project 1134-D
Fibre Channel Arbitrated Loop (FC-AL) ANSI X3.272-1996
Fibre Channel Protocol for SCSI (FCP) ANSI X3.269-1996
SCSI-3 Architecture Model (SAM) Fibre Channel Private Loop SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996
SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996
SCSI Direct Attach (FC-PLDA) NCITS TR-19:1998
Fabric Loop Attachment (FC-FLA), NCITS TR-20:1998
SunOS 5.10 2 Dec 2004 fp(7d)