11-17-2008
How to change the Kernel parameter MAXDSIZE
Hi,
How can I change the Kernel parameter MAXDSIZE??
Thanks in Advance ...
10 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
Hi all
How to change the system parameter (kernel Parameter)
in sun solaris..i wan't to increase the maximum no of user processs.i found it frm sysdef command that it has a value of 3048
i wan't to increase it as smtime while forking a new proceess it,s giving error max limit of user process... (1 Reply)
Discussion started by: Prafulla
1 Replies
2. UNIX for Dummies Questions & Answers
Hi all
I am using HPUX 11.00 .its a HP9000 L class server with 1gb ram and dual processor 540Mhz.
i want to know abt the two kernel parameter mentioned below
1)maxdsize
2)maxssize
these two parameter has the default values and it has not been changed once.
as some application on this... (1 Reply)
Discussion started by: Prafulla
1 Replies
3. UNIX for Dummies Questions & Answers
Hello All,
can someone clarify finally what are the kernel parameter settings
for ORACLE9i on SOLARIS9 ?
the following first part is copy paste from the sun's web... (2 Replies)
Discussion started by: grep
2 Replies
4. UNIX for Dummies Questions & Answers
Hello and thank you everyone that has helped guide me in the past.
I need to change the max_thread_proc parameter in order for certain Oracle utilities to function correctly. It is currently set at 64.
I am a dba not an sa so please excuse my lack of knowledge on something that is probably... (7 Replies)
Discussion started by: soestx
7 Replies
5. UNIX for Dummies Questions & Answers
Hello everbody:
I have Sol9, and I need to check its kernekl parameters, do you know how to list them or in which file they can be found.
Thanks in Advance (3 Replies)
Discussion started by: aladdin
3 Replies
6. UNIX for Advanced & Expert Users
Can anyone reference me where I can find info
or if someone knows the mapping of Solaris kernel parameters to HP-UX 11i v2 O/S on Integrity server?
Your response would be greatly appreciated.
Thanks.
-Lou :) (1 Reply)
Discussion started by: nylou97
1 Replies
7. HP-UX
Hi,
May I pls. know what would be the equivalent kernel parameter in HP-UX for the below Linux kernel parameter.
sysctl kern.ps_showallprocs - This setting in Linux would let users see their own processes in "ps".
Thanks,
Narasimha (1 Reply)
Discussion started by: vnarsim
1 Replies
8. UNIX for Dummies Questions & Answers
Hi All
Need to find kernel parameter values of our UNIX box.
/filesys1/tmp>uname -a
HP-UX hps1_dc B.11.11 U 9000/800 1681349356 unlimited-user license
/filesys1/CDBLprodrun/tmp>
Can anyone help me with the cmd to find kernel parameter values?
Thanks in advance. (1 Reply)
Discussion started by: mhbd
1 Replies
9. HP-UX
Hi.
I wanted to know, that if an issue is coming, where ,on running a load test, the memory of the APP server(unix) increases, but does not come down once the test is over, in that case, does tuning the nk thread paramter help in teleasing of the memory..???
plz answer soon (2 Replies)
Discussion started by: TC123
2 Replies
10. Solaris
Hi gurus
Could anybody tell me that what are the kernal parameter of network interface in solaris
Regards (3 Replies)
Discussion started by: girish.batra
3 Replies
LEARN ABOUT HPUX
nstrsched
NSTRSCHED(5) File Formats Manual NSTRSCHED(5)
NAME
NSTRSCHED - number of STREAMS scheduler daemons to run
VALUES
Failsafe
Default
Allowed values
Recommended values
DESCRIPTION
This tunable defines the number of multiprocessor (MP) STREAMS scheduler daemons to run on systems containing more than one processor.
Note that uniprocessor (UP) systems do not use an MP scheduler daemon, but both MP and UP systems always have one UP STREAMS scheduler
(supsched).
If the tunable value is set to zero, the system determines how many daemons to run, based on the number of processors in the system. If
the tunable value is set to a positive, non-zero value, that is the number of smpsched daemons that will be created on an MP system.
Note: This tunable is for use by specific HP products only. It may be removed in future HP-UX releases.
Who Is Expected to Change This Tunable?
Any customer.
Restrictions on Changing
Changes to this tunable take effect at next reboot.
When Should the Value of This Tunable Be Raised?
This tunable is for use by specific HP products only. It may be removed in future HP-UX releases.
What Are the Side Effects of Raising the Value of This Tunable?
It could change the system performance unpredictably.
When Should the Value of This Tunable Be Lowered?
This tunable is for use by specific HP products only. It may be removed in future HP-UX releases.
What Are the Side Effects of Lowering the Value of This Tunable?
It could change the system performance unpredictably.
What Other Tunable Should Be Changed at the Same Time as This One?
None.
WARNINGS
This tunable is for use by specific HP products only.
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of
HP-UX.
Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation,
some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun-
able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was
factory installed on your system, see at
AUTHOR
was developed by HP.
Tunable Kernel Parameters NSTRSCHED(5)