Install Solaris 10 with an internal StorageTek SAS HBA Raid card

Hi all
i would like to ask some suggests about my next job!
I have to install a new Sun Netra T5220, with an additional internal StorageTek SAS HBA Raid.

The problem come in if every disk is now controlled by the HBA, how can I install the OS?
No disk is being detected by the OS.
SAS card detected with no issue.

Is network install the only way out?


Thanks in advance.

Regards
 

8 More Discussions You Might Find Interesting

1. Solaris

istall sas raid HBA internal card

I need to install a raid HBA internal card on a T5240. The reason is I have more drives and the current mother board controller does not support more than 4 drives. My question is I have raidctl set up on current drives. If I install new HBA card do I have to delete current raidctl and... (3 Replies)
Discussion started by: photon
3 Replies

2. UNIX for Advanced & Expert Users

Sun internal disks and HBA card

I have a V490 that has couple internal disks attached to the same dual-port HBA card that I'm planning attach to the SAN for additional storage. Would I sacrifice performance if I use the same HBA? Is it better to throw in a new HBA instead? (1 Reply)
Discussion started by: kiem
1 Replies

3. Solaris

installing solaris with StorageTek SAS RAID Internal HBA

i was given a task which needs to perform a raid 1 on the boot disk, and 4 other disks on raid 10. Is there any other alternative in installing solaris 10 other than through network installation?will be using solaris update 6. while reading through the user guide i got pretty confuse. ... (1 Reply)
Discussion started by: monstar1407
1 Replies

4. Solaris

T5240 and Internal SAS RAID Configuration help

Dear Friends, I need to configure T5240 with Internal SAS RAID HBA(SG-XPCIESAS-R-INT-Z).. T5240 uses 8 hard disks... From the documents of RAID card I have found that I need to create a jump start server to include three packages SUNWaac, StorMan, SUNWgccruntime if Im using solaris10 5/08... ... (5 Replies)
Discussion started by: nicktrix
5 Replies

5. Solaris

After update Solaris version, HBA driver still need to install?

Hi all I had update a server from Solaris 8 to Solaris 10 is it the HBA driver still need to reinstall? since i can get the driver info as below: root@sgerpdev # fcinfo hba-port HBA Port WWN: 21000003ba9b58a3 OS Device Name: /dev/cfg/c1 Manufacturer: QLogic Corp. ... (1 Reply)
Discussion started by: SmartAntz
1 Replies

6. Solaris

How to enable hba port of a two port hba card

Hi, i have a two port hba card in solaris 10 system one of which is disabled. How to enable and configure the other port. ---------- Post updated at 08:17 AM ---------- Previous update was at 03:40 AM ---------- please help :( (7 Replies)
Discussion started by: rishiraaz
7 Replies

7. AIX

SCSI PCI - X RAID Controller card RAID 5 AIX Disks disappeared

Hello, I have a scsi pci x raid controller card on which I had created a disk array of 3 disks when I type lspv ; I used to see 3 physical disks ( two local disks and one raid 5 disk ) suddenly the raid 5 disk array disappeared ; so the hardware engineer thought the problem was with SCSI... (0 Replies)
Discussion started by: filosophizer
0 Replies

8. Solaris

Solaris 10: how to disable an unused HBA card

Dear all, I have a new Oracle Blade X4-2B server, running Solaris 10. The server comes with a HBA card that will not be used now. It has not fibers connected to it. As a consequence, its leds never stop flashing. My question is: how to disable this HBA card, without removing it physically... (2 Replies)
Discussion started by: Gus1971
2 Replies
MRSAS(4)						   BSD Kernel Interfaces Manual 						  MRSAS(4)

NAME
mrsas -- LSI MegaRAID 6Gb/s and 12Gb/s SAS+SATA RAID controller driver SYNOPSIS
To compile this driver into the kernel, place the following lines in your kernel configuration file: device pci device mrsas Alternatively, to load the driver as a module at boot time, place the following line in loader.conf(5): mrsas_load="YES" DESCRIPTION
The mrsas driver will detect LSI's next generation (6Gb/s and 12Gb/s) PCI Express SAS/SATA RAID controllers. See the HARDWARE section for the supported devices list. A disk (virtual disk/physical disk) attached to the mrsas driver will be visible to the user through camcontrol(8) as /dev/da? device nodes. A simple management interface is also provided on a per-controller basis via the /dev/mrsas? device node. The mrsas name is derived from the phrase "MegaRAID SAS HBA", which is substantially different than the old "MegaRAID" Driver mfi(4) which does not connect targets to the cam(4) layer and thus requires a new driver which attaches targets to the cam(4) layer. Older MegaRAID con- trollers are supported by mfi(4) and will not work with mrsas, but both the mfi(4) and mrsas drivers can detect and manage the LSI MegaRAID SAS 2208/2308/3008/3108 series of controllers. The device.hints(5) option is provided to tune the mrsas driver's behavior for LSI MegaRAID SAS 2208/2308/3008/3108 controllers. By default, the mfi(4) driver will detect these controllers. See the PRIORITY section to know more about driver priority for MR-Fusion devices. mrsas will provide a priority of (-30) (between BUS_PROBE_DEFAULT and BUS_PROBE_LOW_PRIORITY) at probe call for device id's 0x005B, 0x005D, and 0x005F so that mrsas does not take control of these devices without user intervention. HARDWARE
The mrsas driver supports the following hardware: [ Thunderbolt 6Gb/s MR controller ] o LSI MegaRAID SAS 9265 o LSI MegaRAID SAS 9266 o LSI MegaRAID SAS 9267 o LSI MegaRAID SAS 9270 o LSI MegaRAID SAS 9271 o LSI MegaRAID SAS 9272 o LSI MegaRAID SAS 9285 o LSI MegaRAID SAS 9286 o DELL PERC H810 o DELL PERC H710/P [ Invader/Fury 12Gb/s MR controller ] o LSI MegaRAID SAS 9380 o LSI MegaRAID SAS 9361 o LSI MegaRAID SAS 9341 o DELL PERC H830 o DELL PERC H730/P o DELL PERC H330 CONFIGURATION
To disable Online Controller Reset(OCR) for a specific mrsas driver instance, set the following tunable value in loader.conf(5): dev.mrsas.X.disable_ocr=1 where X is the adapter number. To change the I/O timeout value for a specific mrsas driver instance, set the following tunable value in loader.conf(5): dev.mrsas.X.mrsas_io_timeout=NNNNNN where NNNNNN is the timeout value in milli-seconds. To change the firmware fault check timer value for a specific mrsas driver instance, set the following tunable value in loader.conf(5): dev.mrsas.X.mrsas_fw_fault_check_delay=NN where NN is the fault check delay value in seconds. The current number of active I/O commands is shown in the dev.mrsas.X.fw_outstanding sysctl(8) variable. DEBUGGING
To enable debugging prints from the mrsas driver, set the hw.mrsas.X.debug_level variable, where X is the adapter number, either in loader.conf(5) or via sysctl(8). The following bits have the described effects: 0x01 Enable informational prints. 0x02 Enable tracing prints. 0x04 Enable prints for driver faults. 0x08 Enable prints for OCR and I/O timeout. 0x10 Enable prints for AEN events. PRIORITY
The mrsas driver will always set a default (-30) priority in the PCI subsystem for selection of MR-Fusion cards. (It is between BUS_PROBE_DEFAULT and BUS_PROBE_LOW_PRIORITY). MR-Fusion Controllers include all cards with the Device IDs - 0x005B, 0x005D, 0x005F. The mfi(4) driver will set a priority of either BUS_PROBE_DEFAULT or BUS_PROBE_LOW_PRIORITY (depending on the device.hints setting) in the PCI subsystem for selection of MR-Fusion cards. With the above design in place, the mfi(4) driver will attach to a MR-Fusion card given that it has a higher priority than mrsas. Using /boot/device.hints (as mentioned below), the user can provide a preference for the mrsas driver to detect a MR-Fusion card instead of the mfi(4) driver. hw.mfi.mrsas_enable="1" At boot time, the mfi(4) driver will get priority to detect MR-Fusion controllers by default. Before changing this default driver selection policy, LSI advises users to understand how the driver selection policy works. LSI's policy is to provide priority to the mfi(4) driver to detect MR-Fusion cards, but allow for the ability to choose the mrsas driver to detect MR-Fusion cards. LSI recommends setting hw.mfi.mrsas_enable="0" for customers who are using the older mfi(4) driver and do not want to switch to mrsas. For those customers who are using a MR-Fusion controller for the first time, LSI recommends using the mrsas driver and setting hw.mfi.mrsas_enable="1". Changing the default behavior is well tested under most conditions, but unexpected behavior may pop up if more complex and unrealistic opera- tions are executed by switching between the mfi(4) and mrsas drivers for MR-Fusion. Switching drivers is designed to happen only one time. Although multiple switching is possible, it is not recommended. The user should decide from Start of Day which driver they want to use for the MR-Fusion card. The user may see different device names when switching from mfi(4) to mrsas. This behavior is Functions As Designed and the user needs to change the fstab(5) entry manually if they are doing any experiments with mfi(4) and mrsas interoperability. FILES
/dev/da? array/logical disk interface /dev/mrsas? management interface SEE ALSO
cam(4), mfi(4), pci(4), device.hints(5), camcontrol(8) HISTORY
The mrsas driver first appeared in FreeBSD 10.1. mfi Driver: mfi(4) is the old FreeBSD driver which started with support for Gen-1 Controllers and was extended to support up to MR-Fusion (Device ID = 0x005B, 0x005D, 0x005F). mrsas Driver: mrsas is the new driver reworked by LSI which supports Thunderbolt and onward products. The SAS+SATA RAID controller with device id 0x005b is referred to as the Thunderbolt controller throughout this man page. cam aware HBA drivers: FreeBSD has a cam(4) layer which attaches storage devices and provides a common access mechanism to storage con- trollers and attached devices. The mrsas driver is cam(4) aware and devices associated with mrsas can be seen using camcontrol(8). The mfi(4) driver does not understand the cam(4) layer and it directly associates storage disks to the block layer. Thunderbolt Controller: This is the 6Gb/s MegaRAID HBA card which has device id 0x005B. Invader Controller: This is 12Gb/s MegaRAID HBA card which has device id 0x005D. Fury Controller: This is the 12Gb/s MegaRAID HBA card which has device id 0x005F. AUTHORS
The mrsas driver and this manual page were written by Kashyap Desai <Kashyap.Desai@lsi.com>. TODO
The driver does not support big-endian architectures at this time. The driver does not support alias for device name (it is required when the user switches between two drivers and does not want to edit /etc/fstab manually). The mrsas driver exposes devices as /dev/da?, whereas mfi(4) exposes devices as /dev/mfid?. mrsas does not support the Linux Emulator interface. mrsas will not work with mfiutil(8). BSD