Sponsored Content
Operating Systems Solaris Resyncing Progress of hardware mirror Post 302253600 by incredible on Saturday 1st of November 2008 06:50:02 AM
Old 11-01-2008
If you see that the disk is resyncing, did you actually check the disk LED is physically blinking?
And by now, I believe that the syncronization should have completed.
 

9 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Checking cp progress

Hi gurus. I wonder if there is some command that will help me to determing the progress of cp. I'm copying huge amount of files, and through the ps x -uoracle see, that it goes 1771 pts/6 S+ 0:37 cp 1_2600_617913793.arc 37 minutes. Is there command, that helps determing on what... (0 Replies)
Discussion started by: MarGur
0 Replies

2. Shell Programming and Scripting

Progress

Maybe someone know how to create something like "*". If someone uses Gentoo he must see this while emerge utility preparing an update. I mean the symbol "/" spins. (2 Replies)
Discussion started by: mirusnet
2 Replies

3. Shell Programming and Scripting

progress bar

hi all, in shell script (ksh), how do i write a progress bar ?? i have a script which searches files and while its searching i am currently printing out "." and if it finds what its searching for the script prints out the name of the file e.g .................. firstFile.txt... (2 Replies)
Discussion started by: cesarNZ
2 Replies

4. Solaris

ZFS Mirror versus Hardware Mirror

I've looked a little but haven't found a solid answer, assuming there is one. What's better, hardware mirroring or ZFS mirroring? Common practice for us was to use the raid controllers on the Sun x86 servers. Now we've been using ZFS mirroring since U6. Any performance difference? Any other... (3 Replies)
Discussion started by: Lespaul20
3 Replies

5. Solaris

What is mirror and sub mirror in RAID -1 SVM

Hi , I am new to SVM .when i try to learn RAID 1 , first they are creating two RAID 0 strips through metainit d51 1 1 c0t0d0s2 metainit d52 1 1 c1t0d0s2 In the next step metainit d50 -m d51 d50: Mirror is setup next step is metaattach d50 d52 d50 : submirror d52 is... (7 Replies)
Discussion started by: vr_mari
7 Replies

6. Emergency UNIX and Linux Support

mdadm unable to fail a resyncing drive?

Hi All I have a RAID 5 array consisting of 4 drives that had a partial drive failure in one of the drives. Rebooting shows the faulty drive as background rebuilding and mdadm /dev/ARRAYID shows three drives as in sync with the fourth drive as spare rebuilding. However the array won't come... (9 Replies)
Discussion started by: Bashingaway
9 Replies

7. Solaris

Hardware faulty, but which hardware?

Hi folk, I have this hardware faunty message, but dont know which hardware is this ? can you guide me ? --------------- ------------------------------------ -------------- --------- TIME EVENT-ID MSG-ID SEVERITY ---------------... (9 Replies)
Discussion started by: dehetoxic
9 Replies

8. HP-UX

What is the difference between DRD and Root Mirror Disk using LVM mirror ?

what is the difference between DRD and Root Mirror Disk using LVM mirror ? (3 Replies)
Discussion started by: maxim42
3 Replies

9. Solaris

Maint, resyncing and last-erred notifications

Hi fellow members! I have a oracle solaris server with two internal disks, that acts as an authentication server only, and for now the server seems to be doing its job, but when typing metastat -c I get some notifications. I am not familiar with SVM, I wonder if someone can help me on this:... (3 Replies)
Discussion started by: fretagi
3 Replies
vxsplitlines(1M)														  vxsplitlines(1M)

NAME
vxsplitlines - show disks with conflicting configuration copies in a cluster SYNOPSIS
vxsplitlines [-g diskgroup] [-c daname] DESCRIPTION
If you import portions of a disk group on different systems, this can lead to conflicting configuration copies on the disks of the disk group. If the configuration information in a disk group is ambiguous, it may not be possible for Veritas Volume Manager to determine which config- uration copy is most up-to-date. (This is usually termed a serial split brain (SSB) condition when it occurs in a cluster.) You cannot import a disk group in this state unless you specify which disk's configuration copy to use. You can use the vxsplitlines command to see which disks in a disk group have conflicting configuration copies, and use this information together with your knowledge of the history of the disk groups' usage to determine which configuration copy is most valid. The output from vxsplitlines displays the vxdg commands that you can run to import the disk group using the available configuration copies. The -o selectcp option of the vxdg import command is used to select the configuration copy to use for the import. OPTIONS
-c daname Display the SSB IDs for each disk that are stored in the configuration copy on the disk specified by its disk access name. Note: Although the SSB IDs for some disks may match, this does not necessarily mean that those disks' configuration copies have recorded all the configuration changes. When viewed from some other configuration copies, the SSB IDs of the same disks may not match. -g diskgroup Specifies the disk group. If a disk group is not specified, the default disk group is used as determined from the rules on the vxdg(1M) manual page. EXAMPLES
Display the disks on each side of the split in the disk group newdg: vxsplitlines -g newdg Display the SSB IDs stored in the configuration copy on disk c2t4d0: vxsplitlines -g newdg -c c2t4d0 NOTES
The vxsplitlines is primarily intended to be used with private disk groups, but it also works with shared disk groups. The version number of the disk group must be 110 or greater. SEE ALSO
vxdg(1M) Veritas Volume Manager Administrator's Guide VxVM 5.0.31.1 24 Mar 2008 vxsplitlines(1M)