Hi Freddo,

Your question isnt clear to me. Sorry, if you can give us more information like below, it would help us.

What is the HP-UX OS you are using?
Is the system up and running now?
Also, are you trying to change the root disk? Or, is that just going to be a data disk?
Is that disk going to be added internally or externally?
Are you planning to use LVM or VXVM for managing?

Finally, is the server hot swapable?

I searched for documents regarding c class 3600 workstation for specifications and dint find any. If you can give us these information, we can then give you procedures..

-DB
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Upgrade Hard Disk to a larger one

Hello folks, I have a sun sparcstation 20, I would like to upgrade one of the hard disks to a larger one. The one I would like to upgrade only contains user data. Here are my thoughts: 1. Backup the specific file system 2. Replace the disk with the larger disk 3. Create a new file... (2 Replies)
Discussion started by: DLongan
2 Replies

2. AIX

Disk upgrade problem

I've tried to upgrade the 9gb drives in our F50's to 18gb. The system with original drives would boot up in about 4 min., but with the 18gb drives takes 17 min. Running 4.2.1. What am I missing here?? (5 Replies)
Discussion started by: mooshkie
5 Replies

3. UNIX for Advanced & Expert Users

3600 tcp/udp, trap-daemon, text relay-answer

3600 tcp/udp, trap-daemon, text relay-answer Does anyone know what this service is responsible for, or how significant it is? Thanks.....James (1 Reply)
Discussion started by: cassj
1 Replies

4. UNIX for Advanced & Expert Users

disk upgrade

Hi all, this s going to be my 1st time upgrading a disk.I need the ways or steps to migrate data from a 2gb disk to a 4gb disk which sits in the High Availability Disk Array Model 10.the os disk is the internal disk of the K200 system so i dont think i would be meddling around with that.what r... (1 Reply)
Discussion started by: giriplug
1 Replies

5. Solaris

Upgrade disk in RAID 1

I need to upgrade 2 x 73 GB disk and replace with 2 x 146 GB disk in sun v240. These disks contain boot and swap files These are mirrored disks with RAID 1 I am trining to create the correct procedure. So far the procedure I have is as follows: # metastat State: Okay ... (5 Replies)
Discussion started by: photon
5 Replies

6. UNIX for Dummies Questions & Answers

How to 'split' mirror disk for OS upgrade purpose

Plan to upgrade Solaris from version 8 to version 9. Understand that if the boot disk is mirrored, I need to split it first before upgrade, how can I do that? Please advise. Thank you. (2 Replies)
Discussion started by: KhawHL
2 Replies

7. UNIX for Advanced & Expert Users

Get pointer for existing device class (struct class) in Linux kernel module

Hi all! I am trying to register a device in an existing device class, but I am having trouble getting the pointer to an existing class. I can create a class in a module, get the pointer to it and then use it to register the device with: *cl = class_create(THIS_MODULE, className);... (0 Replies)
Discussion started by: hdaniel@ualg.pt
0 Replies

8. Programming

Size of Derived class, upon virtual base class inheritance

I have the two class definition as follows. class A { public: int a; }; class B : virtual public A{ }; The size of class A is shown as 4, and size of class B is shown as 16. Why is this effect ?. (2 Replies)
Discussion started by: techmonk
2 Replies

9. Programming

C++ : Base class member function not accessible from derived class

Hello All, I am a learner in C++. I was testing my inheritance knowledge with following piece of code. #include <iostream> using namespace std; class base { public : void display() { cout << "In base display()" << endl; } void display(int k) {... (2 Replies)
Discussion started by: anand.shah
2 Replies

10. Solaris

How to use live-upgrade with single disk, pre-patching steps?

Hi, I have Solaris-10 x86 (running on HP hardware), with 12 non-global zones running on this. I have to install latest patch cluster/set on this server. This server is not under backup schedule, so before installing patch cluster, I want to keep a backup. In case of any issue (bad patch or... (4 Replies)
Discussion started by: solaris_1977
4 Replies
pfto(7) 						 Miscellaneous Information Manual						   pfto(7)

NAME
pfto - Powerfail Timeout DESCRIPTION
HP-UX SCSI disk device drivers have a timeout facility that detects non-responding disks. VxVM uses this mechanism in its Powerfail Time- out (pfto) feature. You can specify a timeout value for individual VxVM disks using the vxdisk command (see the EXAMPLES section below). If a disk fails to respond in the specified timeout period, the driver receives a timer interrupt. pfto values are persistent across reboots, that is, after the pfto value is set, it remains in effect until you explicitly change it. If dynamic multipathing is enabled, the pfto value set on a disk applies to each path of a multipath disk device. The pfto value is in seconds. If pfto is not specified, or is zero, the timeout period is 30 seconds. Both the vxdisk and vxprint commands display the current pfto value for a disk. EXAMPLES
Use the following command to set the value of pfto to 30 seconds on disk01: vxdisk -g rootdg set disk01 pfto=30 Use either of the following commands to display the pfto value on the VxVM disk disk01: vxdisk list disk01 vxprint -l disk01 EXIT CODES
Setting the pfto value on a non-VxVM disk returns an error. SEE ALSO
vxdisk(1M), vxprint(1M) VxVM 5.0.31.1 24 Mar 2008 pfto(7)