Sponsored Content
Operating Systems Solaris How to setup hardware RAID on a T2000 Post 302243566 by Grippo on Monday 6th of October 2008 03:45:38 AM
Old 10-06-2008
Quote:
Originally Posted by DukeNuke2
i'm not a friend of hardware raid on boot devices. why not use softraid to mirror the root disk? it is much easier to access the disk if you encounter any problems...
Agreed - I prefer to remain reliant on the KISS (Keep It Simple Stupid) principle for the boot devices.

We have HW RAID configured on a server and it removes the flexibility from your disks. Sometimes is can be uses full to be able to split a mirror and keep a copy while some work is on-going on a system disk.

Also, with SW mirroring, if you "urgently" need to borrow some disk space for something, you can split the mirror, use it and then reattach the mirrors afterwards.
 

9 More Discussions You Might Find Interesting

1. Solaris

Hardware RAID

I don't understood why on SPARC-Platforms have not present RAID-Controller ? Sorry for my bad english, but it's crazy always setup software RAID !!! I whanna Hardware RAID and when i can find solution ? (7 Replies)
Discussion started by: jess_t03
7 Replies

2. Solaris

T2000 Hardware RAID

Hi, I have a root with hardware RAID on c0t0d0 and c0t2d0. I would like to set the boot device sequence in OBP for both hdds. I have checked in ls -l /dev/rdsk/ for the path of c0t2d0 but it does not exist. Can anyone shed some lights on this? AVAILABLE DISK SELECTIONS: 0.... (12 Replies)
Discussion started by: honmin
12 Replies

3. Solaris

T2000 RAID Question

New to the boards here so please bear with me! I have a T2000 server with Solaris 10 installed on it. Disk 0 is the only disk currently being used, as I do NOT have a RAID set up. Disk 1 is just sitting there looking pretty. I'd like to set up a mirrored RAID in order to fully utilize both... (5 Replies)
Discussion started by: phi148
5 Replies

4. Solaris

Raid problem on T2000

Hi all, First post so be gentile :) It's my first time installing Solaris on T2000 server. I have 2 72GB HD's on it. After configuring HW raid and running raidctl command I get this output: bash-3.00# raidctl -l c0t0d0 Volume Size Stripe Status Cache RAID ... (2 Replies)
Discussion started by: Obi-Wan
2 Replies

5. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

6. Solaris

Hardware Raid - LiveUpgrade

Hi, I have a question. Do LiveUpgrade supports hardware raid? How to choose the configuration of the system disk for Solaris 10 SPARC? 1st Hardware RAID-1 and UFS 2nd Hardware RAID-1 and ZFS 3rd SVM - UFS and RAID1 4th Software RAID-1 and ZFS I care about this in the future to take... (1 Reply)
Discussion started by: bieszczaders
1 Replies

7. Hardware

Hardware RAID on Sun T2000 Server

Hi All I have a Sun T2000 server. Couple of years ago I had configured and mirrored the boot drive with an other drive using hardware RAID 1 using raidctl command. Following is the hardware RAID output. root@oracledatabaseserver / $ raidctl RAID Volume RAID RAID Disk... (0 Replies)
Discussion started by: Tirmazi
0 Replies

8. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

9. Solaris

Hardware RAID using three disks

Dear All , Pl find the below command , # raidctl -l Controller: 1 Volume:c1t0d0 Disk: 0.0.0 Disk: 0.1.0 Disk: 0.3.0 # raidctl -l c1t0d0 Volume Size Stripe Status Cache RAID Sub Size ... (10 Replies)
Discussion started by: jegaraman
10 Replies
CCDCONFIG(8)						    BSD System Manager's Manual 					      CCDCONFIG(8)

NAME
ccdconfig -- configuration utility for the concatenated disk driver SYNOPSIS
ccdconfig [-cv] ccd ileave [flags] dev ... ccdconfig -C [-v] [-f config_file] ccdconfig -u [-v] ccd ... ccdconfig -U [-v] [-f config_file] ccdconfig -g [ccd ...] DESCRIPTION
The ccdconfig utility is used to dynamically configure and unconfigure concatenated disk devices, or ccds. For more information about the ccd, see ccd(4). The options are as follows: -c Configure a ccd. This is the default behavior of ccdconfig. -C Configure all ccd devices listed in the ccd configuration file. -f config_file When configuring or unconfiguring all devices, read the file config_file instead of the default /etc/ccd.conf. -g Dump the current ccd configuration in a format suitable for use as the ccd configuration file. If no arguments are specified, every configured ccd is dumped. Otherwise, the configuration of each listed ccd is dumped. -u Unconfigure a ccd. -U Unconfigure all ccd devices listed the ccd configuration file. -v Cause ccdconfig to be verbose. A ccd is described on the command line and in the ccd configuration file by the name of the ccd, the interleave factor, the ccd configuration flags, and a list of one or more devices. The flags may be represented as a decimal number, a hexadecimal number, a comma-separated list of strings, or the word ``none''. The flags are as follows: CCDF_UNIFORM 0x02 Use uniform interleave CCDF_MIRROR 0x04 Support mirroring CCDF_NO_OFFSET 0x08 Do not use an offset CCDF_LINUX 0x0A Linux md(4) compatibility The format in the configuration file appears exactly as if it were entered on the command line. Note that on the command line and in the configuration file, the flags argument is optional. # # /etc/ccd.conf # Configuration file for concatenated disk devices # # ccd ileave flags component devices ccd0 16 none /dev/da2s1 /dev/da3s1 The component devices need to name partitions of type FS_BSDFFS (or ``4.2BSD'' as shown by disklabel(8)). If you want to use the Linux md(4) compatibility mode, please be sure to read the notes in ccd(4). FILES
/etc/ccd.conf default ccd configuration file EXAMPLES
A number of ccdconfig examples are shown below. The arguments passed to ccdconfig are exactly the same as you might place in the /etc/ccd.conf configuration file. The first example creates a 4-disk stripe out of four scsi disk partitions. The stripe uses a 64 sector interleave. The second example is an example of a complex stripe/mirror combination. It reads as a two disk stripe of da4 and da5 which is mirrored to a two disk stripe of da6 and da7. The last example is a simple mirror. The 2nd slice of /dev/da8 is mirrored with the 3rd slice of /dev/da9 and assigned to ccd0. # ccdconfig ccd0 64 none /dev/da0s1 /dev/da1s1 /dev/da2s1 /dev/da3s1 # ccdconfig ccd0 128 CCDF_MIRROR /dev/da4 /dev/da5 /dev/da6 /dev/da7 # ccdconfig ccd0 128 CCDF_MIRROR /dev/da8s2 /dev/da9s3 The following are matching commands in Linux and FreeBSD to create a RAID-0 in Linux and read it from FreeBSD. # Create a RAID-0 on Linux: mdadm --create --chunk=32 --level=0 --raid-devices=2 /dev/md0 /dev/hda1 /dev/hdb1 # Make the RAID-0 just created available on FreeBSD: ccdconfig -c /dev/ccd0 32 linux /dev/ada0s1 /dev/ada0s2 When you create a new ccd disk you generally want to fdisk(8) and disklabel(8) it before doing anything else. Once you create the initial label you can edit it, adding additional partitions. The label itself takes up the first 16 sectors of the ccd disk. If all you are doing is creating file systems with newfs, you do not have to worry about this as newfs will skip the label area. However, if you intend to dd(1) to or from a ccd partition it is usually a good idea to construct the partition such that it does not overlap the label area. For example, if you have A ccd disk with 10000 sectors you might create a 'd' partition with offset 16 and size 9984. # disklabel ccd0 > /tmp/disklabel.ccd0 # disklabel -Rr ccd0 /tmp/disklabel.ccd0 # disklabel -e ccd0 The disklabeling of a ccd disk is usually a one-time affair. If you reboot the machine and reconfigure the ccd disk, the disklabel you had created before will still be there and not require reinitialization. Beware that changing any ccd parameters: interleave, flags, or the device list making up the ccd disk, will usually destroy any prior data on that ccd disk. If this occurs it is usually a good idea to reini- tialize the label before [re]constructing your ccd disk. RECOVERY
An error on a ccd disk is usually unrecoverable unless you are using the mirroring option. But mirroring has its own perils: It assumes that both copies of the data at any given sector are the same. This holds true until a write error occurs or until you replace either side of the mirror. This is a poor-man's mirroring implementation. It works well enough that if you begin to get disk errors you should be able to backup the ccd disk, replace the broken hardware, and then regenerate the ccd disk. If you need more than this you should look into external hardware RAID SCSI boxes, RAID controllers (see GENERIC), or software RAID systems such as geom(8) and gvinum(8). SEE ALSO
dd(1), ccd(4), disklabel(8), fdisk(8), gvinum(8), rc(8) HISTORY
The ccdconfig utility first appeared in NetBSD 1.0A. BUGS
The initial disklabel returned by ccd(4) specifies only 3 partitions. One needs to change the number of partitions to 8 using ``disklabel -e'' to get the usual BSD expectations. BSD
October 1, 2013 BSD
All times are GMT -4. The time now is 05:40 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy