Just zone the luns to the vioserver. mkvdev will map them from the vios to the vioclient. Look at 9b en 9c, everything is in the link.
 

10 More Discussions You Might Find Interesting

1. AIX

Problems AIX and SAN.

Sorry for my english. We have a IBM BLADES JS21. AIX 5.3 update to 6. Our JS21 has 2 FC (fcs0 and fcs1). We have one DS4072, one Disk system with 2 controllers and 2 FC by controllers. This means, all AIX FC see all Disk systems controllers by 2 FC switchs. (one fc two roads) FC AIX... (4 Replies)
Discussion started by: fjgonzalez
4 Replies

2. AIX

AIX disk less with SAN

Hi All, I have mirrored SAN volume on my B80 rootvg. Can I just remove the mirror and "Remove a P V from a V G" and it will be a diskless AIX? Is that going to boot on SAN rootvg volume? Thanks in advance, itik (3 Replies)
Discussion started by: itik
3 Replies

3. AIX

how to increase FS size on SAN DS4800 ?

Hello, I am using DS4800 SAN with AIX 5.3, and would like to increase the size of the DS4800 Luns, so that my FS increase also. How to do this please ? Modifying Lun risk to make all data of the FS being lost ! NO ? (8 Replies)
Discussion started by: astjen
8 Replies

4. AIX

AIX & DS4800 error

Hi people... i have a problem with a DS4800 san... it keeps me showing this message (on picture) and i dont know how to solve it! someone knows? thanks a lot (2 Replies)
Discussion started by: gfca
2 Replies

5. AIX

Increase LUN size in AIX with VIOS and HACMP

Hello! I have this infraestructure: - 1 POWER7 with single VIOS on Site A. - 1 POWER6 with single VIOS on Site B. - 1 LPAR called NodeA as primary node for PowerHA 6.1 on Site A. - 1 LPAR called NodeB as secondary (cold) node for PowerHA 6.1 on SiteB. - 1 Storage DS4700 on Site A. - 1... (8 Replies)
Discussion started by: enzote
8 Replies

6. AIX

VIOS IP address - separate vlan for vios servers ?

Hello, Lets say for simplicity that I do not use any vlan config inside my server - one lpar group use hea physical port1, another group hea physical port2. Physical port1 configured as vlan1 on external switch, physical port2 as vlan2. What is the common practice - should I isolate my vios... (0 Replies)
Discussion started by: vilius
0 Replies

7. AIX

AIX VIOS IVM Ethernet problem

Hi All, I have a p520 box running 3 LPARs, 1 x VIOS, 1 x AIX 6.1 and 1 x AIX 7.1 and no HMC, all configuration is performed via VIOS/IVM Until recently the box did not have the AIX7.1 LPAR and everything was fine with the box. We needed to use AIX 7.1 for a new project, so I created a... (11 Replies)
Discussion started by: KevB
11 Replies

8. AIX

Revisiting IBM PowerVM VIOS AIX

coming from this thread: https://www.unix.com/aix/211107-ibm-power-pseries-open-firmware-boot-vios-powervm-vet-code.html PowerVM, formerly known as Advanced Power Virtualization (APV), is a chargeable feature of IBM POWER5, POWER6, POWER7, POWER8, and POWER9 servers and is required for support... (0 Replies)
Discussion started by: filosophizer
0 Replies

9. UNIX for Advanced & Expert Users

Unable to install client AIX LPAR to vscsi hdisk provided from VIOS

Hi everybody, I have Power5 server with 4 internal hdisks each of 70Gb. VIOS server was installed via Virtual I/O Server Image Repository on the HMC. HMC release - 7.7.0 VIOS rootvg installed on 2 disk(these disks merged to one storage pool during VIOS install process),and 2 others hdisks... (2 Replies)
Discussion started by: Ravil Khalilov
2 Replies

10. AIX

IBM VIOS AIX HMC Error

hello P6 was managed by HMC, tried to install on it VIOS 2.2.6 and got this error message Hosting requires a hosting partition -- boot not permitted vios-4 - imgbb.com then after creating an lpar in HMC got this message B2001230 vios-3 - imgbb.com anyone know how to solve this... (3 Replies)
Discussion started by: filosophizer
3 Replies
fcd_disable_mgmt_lun(5) 					File Formats Manual					   fcd_disable_mgmt_lun(5)

NAME
fcd_disable_mgmt_lun - select whether or not management luns are discovered in the legacy representation of mass storage devices VALUES
Failsafe Default Allowed values Enable discovery of management luns for array devices. Disable discovery of management luns for array devices. Recommended values DESCRIPTION
Management luns provide the means to access the control ports of Fibre Channel disk arrays. They are represented in both the legacy and the agile view of storage devices. The legacy representation of a management lun is typically created under a separate virtual extension bus node. The entry for a legacy management lun looks like this: On a system with a large number of storage devices connected, creation of management luns can result in an insufficient number of virtual extension buses for the legacy representation of data luns. Since the number of extension buses on a system is limited to 256, luns requiring virtual extension buses above 256 will be unusable through legacy device special files. Disabling the discovery and creation of management luns will free up virtual extension buses for use by data luns. The default value for this tunable is Who Is Expected to Change This Tunable? System administrators who expect to use a large number of storage devices requiring more than 256 extension buses through legacy device special files. Restrictions on Changing Changes to this tunable take effect immediately. However, existing management luns will not be removed. When Should the Tunable Be Turned On? This tunable should be turned on when the system runs out of extension buses for configuring the legacy representation of data luns. What Are the Side Effects of Turning the Tunable Off? None. When Should the Tunable Be Turned Off? When the functionality provided by the management lun is desired. What Are the Side Effects of Turning the Tunable On? Existing management luns in the legacy representation will show up in the state. What Other Tunables Should Be Changed at the Same Time? None. WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of HP-UX. Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation, some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun- able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was factory installed on your system, see at AUTHOR
was developed by Hewlett-Packard Company. SEE ALSO
ioinit(1M), ioscan(1M), kctune(1M). Tunable Kernel Parameters fcd_disable_mgmt_lun(5)