09-17-2008
10 More Discussions You Might Find Interesting
1. AIX
Sorry for my english.
We have a IBM BLADES JS21. AIX 5.3 update to 6.
Our JS21 has 2 FC (fcs0 and fcs1).
We have one DS4072, one Disk system with 2 controllers and 2 FC by controllers.
This means, all AIX FC see all Disk systems controllers by 2 FC switchs. (one fc two roads)
FC AIX... (4 Replies)
Discussion started by: fjgonzalez
4 Replies
2. AIX
Hi All,
I have mirrored SAN volume on my B80 rootvg. Can I just remove the mirror and "Remove a P V from a V G" and it will be a diskless AIX?
Is that going to boot on SAN rootvg volume?
Thanks in advance,
itik (3 Replies)
Discussion started by: itik
3 Replies
3. AIX
Hello,
I am using DS4800 SAN with AIX 5.3, and would like to increase the size of the DS4800 Luns, so that my FS increase also.
How to do this please ?
Modifying Lun risk to make all data of the FS being lost ! NO ? (8 Replies)
Discussion started by: astjen
8 Replies
4. AIX
Hi people...
i have a problem with a DS4800 san... it keeps me showing this message (on picture) and i dont know how to solve it!
someone knows?
thanks a lot (2 Replies)
Discussion started by: gfca
2 Replies
5. AIX
Hello!
I have this infraestructure:
- 1 POWER7 with single VIOS on Site A.
- 1 POWER6 with single VIOS on Site B.
- 1 LPAR called NodeA as primary node for PowerHA 6.1 on Site A.
- 1 LPAR called NodeB as secondary (cold) node for PowerHA 6.1 on SiteB.
- 1 Storage DS4700 on Site A.
- 1... (8 Replies)
Discussion started by: enzote
8 Replies
6. AIX
Hello,
Lets say for simplicity that I do not use any vlan config inside my server - one lpar group use hea physical port1, another group hea physical port2. Physical port1 configured as vlan1 on external switch, physical port2 as vlan2.
What is the common practice - should I isolate my vios... (0 Replies)
Discussion started by: vilius
0 Replies
7. AIX
Hi All,
I have a p520 box running 3 LPARs, 1 x VIOS, 1 x AIX 6.1 and 1 x AIX 7.1 and no HMC, all configuration is performed via VIOS/IVM
Until recently the box did not have the AIX7.1 LPAR and everything was fine with the box.
We needed to use AIX 7.1 for a new project, so I created a... (11 Replies)
Discussion started by: KevB
11 Replies
8. AIX
coming from this thread: https://www.unix.com/aix/211107-ibm-power-pseries-open-firmware-boot-vios-powervm-vet-code.html
PowerVM, formerly known as Advanced Power Virtualization (APV), is a chargeable feature of IBM POWER5, POWER6, POWER7, POWER8, and POWER9 servers and is required for support... (0 Replies)
Discussion started by: filosophizer
0 Replies
9. UNIX for Advanced & Expert Users
Hi everybody,
I have Power5 server with 4 internal hdisks each of 70Gb.
VIOS server was installed via Virtual I/O Server Image Repository on the HMC.
HMC release - 7.7.0
VIOS rootvg installed on 2 disk(these disks merged to one storage pool during VIOS install process),and 2 others hdisks... (2 Replies)
Discussion started by: Ravil Khalilov
2 Replies
10. AIX
hello
P6 was managed by HMC, tried to install on it VIOS 2.2.6
and got this error message
Hosting requires a hosting partition -- boot not permitted
vios-4 - imgbb.com
then after creating an lpar in HMC got this message
B2001230
vios-3 - imgbb.com
anyone know how to solve this... (3 Replies)
Discussion started by: filosophizer
3 Replies
LEARN ABOUT OSX
urn-scheme
uri_urn(n) Tcl Uniform Resource Identifier Management uri_urn(n)
__________________________________________________________________________________________________________________________________________________
NAME
uri_urn - URI utilities, URN scheme
SYNOPSIS
package require Tcl 8.2
package require uri::urn ?1.1.2?
uri::urn::quote url
uri::urn::unquote url
_________________________________________________________________
DESCRIPTION
This package provides two commands to quote and unquote the disallowed characters for url using the urn scheme, registers the scheme with
the package uri, and provides internal helpers which will be automatically used by the commands uri::split and uri::join of package uri to
handle urls using the urn scheme.
COMMANDS
uri::urn::quote url
This command quotes the characters disallowed by the urn scheme (per RFC 2141 sec2.2) in the url and returns the modified url as its
result.
uri::urn::unquote url
This commands performs the reverse of ::uri::urn::quote. It takes an urn url, removes the quoting from all disallowed characters,
and returns the modified urls as its result.
BUGS, IDEAS, FEEDBACK
This document, and the package it describes, will undoubtedly contain bugs and other problems. Please report such in the category uri of
the Tcllib SF Trackers [http://sourceforge.net/tracker/?group_id=12883]. Please also report any ideas for enhancements you may have for
either package and/or documentation.
KEYWORDS
rfc 2141, uri, url, urn
CATEGORY
Networking
uri 1.1.2 uri_urn(n)