Operating Systems AIX AIX, VIOS and DS4800 SAN Post 302236728 by gfca on Tuesday 16th of September 2008 08:05:07 AM
Old 09-16-2008
AIX, VIOS and DS4800 SAN

Hello

I have a system with four AIX 5L V5.3 partitions and a Virtual I/O server, connected to a a DS4800 storage array.

Now the company bought another DS4800... i made raid on it... and now i wanna give LUN's to the VIOS, so i can use in one of AIX partitions...

Someone can help me?

Sorry if i miss something but im new in this! Smilie

Thanks a lot
 

10 More Discussions You Might Find Interesting

1. AIX

Problems AIX and SAN.

Sorry for my english. We have a IBM BLADES JS21. AIX 5.3 update to 6. Our JS21 has 2 FC (fcs0 and fcs1). We have one DS4072, one Disk system with 2 controllers and 2 FC by controllers. This means, all AIX FC see all Disk systems controllers by 2 FC switchs. (one fc two roads) FC AIX... (4 Replies)
Discussion started by: fjgonzalez
4 Replies

2. AIX

AIX disk less with SAN

Hi All, I have mirrored SAN volume on my B80 rootvg. Can I just remove the mirror and "Remove a P V from a V G" and it will be a diskless AIX? Is that going to boot on SAN rootvg volume? Thanks in advance, itik (3 Replies)
Discussion started by: itik
3 Replies

3. AIX

how to increase FS size on SAN DS4800 ?

Hello, I am using DS4800 SAN with AIX 5.3, and would like to increase the size of the DS4800 Luns, so that my FS increase also. How to do this please ? Modifying Lun risk to make all data of the FS being lost ! NO ? (8 Replies)
Discussion started by: astjen
8 Replies

4. AIX

AIX & DS4800 error

Hi people... i have a problem with a DS4800 san... it keeps me showing this message (on picture) and i dont know how to solve it! someone knows? thanks a lot (2 Replies)
Discussion started by: gfca
2 Replies

5. AIX

Increase LUN size in AIX with VIOS and HACMP

Hello! I have this infraestructure: - 1 POWER7 with single VIOS on Site A. - 1 POWER6 with single VIOS on Site B. - 1 LPAR called NodeA as primary node for PowerHA 6.1 on Site A. - 1 LPAR called NodeB as secondary (cold) node for PowerHA 6.1 on SiteB. - 1 Storage DS4700 on Site A. - 1... (8 Replies)
Discussion started by: enzote
8 Replies

6. AIX

VIOS IP address - separate vlan for vios servers ?

Hello, Lets say for simplicity that I do not use any vlan config inside my server - one lpar group use hea physical port1, another group hea physical port2. Physical port1 configured as vlan1 on external switch, physical port2 as vlan2. What is the common practice - should I isolate my vios... (0 Replies)
Discussion started by: vilius
0 Replies

7. AIX

AIX VIOS IVM Ethernet problem

Hi All, I have a p520 box running 3 LPARs, 1 x VIOS, 1 x AIX 6.1 and 1 x AIX 7.1 and no HMC, all configuration is performed via VIOS/IVM Until recently the box did not have the AIX7.1 LPAR and everything was fine with the box. We needed to use AIX 7.1 for a new project, so I created a... (11 Replies)
Discussion started by: KevB
11 Replies

8. AIX

Revisiting IBM PowerVM VIOS AIX

coming from this thread: https://www.unix.com/aix/211107-ibm-power-pseries-open-firmware-boot-vios-powervm-vet-code.html PowerVM, formerly known as Advanced Power Virtualization (APV), is a chargeable feature of IBM POWER5, POWER6, POWER7, POWER8, and POWER9 servers and is required for support... (0 Replies)
Discussion started by: filosophizer
0 Replies

9. UNIX for Advanced & Expert Users

Unable to install client AIX LPAR to vscsi hdisk provided from VIOS

Hi everybody, I have Power5 server with 4 internal hdisks each of 70Gb. VIOS server was installed via Virtual I/O Server Image Repository on the HMC. HMC release - 7.7.0 VIOS rootvg installed on 2 disk(these disks merged to one storage pool during VIOS install process),and 2 others hdisks... (2 Replies)
Discussion started by: Ravil Khalilov
2 Replies

10. AIX

IBM VIOS AIX HMC Error

hello P6 was managed by HMC, tried to install on it VIOS 2.2.6 and got this error message Hosting requires a hosting partition -- boot not permitted vios-4 - imgbb.com then after creating an lpar in HMC got this message B2001230 vios-3 - imgbb.com anyone know how to solve this... (3 Replies)
Discussion started by: filosophizer
3 Replies
HYPER-V(4)						   BSD Kernel Interfaces Manual 						HYPER-V(4)

NAME
hv_utils -- Hyper-V Utilities Driver SYNOPSIS
To compile this driver into the kernel, place the following lines in the system kernel configuration file: device hyperv DESCRIPTION
The hv_utils driver provides time keeping, shutdown and heartbeat functionality for FreeBSD guest partitions running on Hyper-V. Hyper-V is a hypervisor-based virtualization technology from Microsoft. The hv_utils driver is one of the core drivers required to be present in guest partitions running on Hyper-V. This driver provides the following functionalities to guest partitions: (a) Time Keeping: The clock inside the guest partition will remain accurate by synchronizing to the clock on the virtualization server via Timesync service, and with the help of the pluggable time source device. (b) Integrated shutdown: Guest partitions running FreeBSD can be shut down from Hyper-V Manager console by using the "Shut down" command. (c) Heartbeat: This feature allows the virtualization server to detect whether the guest partition is running and responsive. SEE ALSO
hv_ata_pci_disengage(4), hv_netvsc(4), hv_storvsc(4), hv_vmbus(4) HISTORY
Support for hv_utils first appeared in FreeBSD 10.0. The driver was developed through a joint effort between Citrix Incorporated, Microsoft Corporation, and Network Appliance Incorporated. AUTHORS
FreeBSD support for hv_utils was first added by Microsoft BSD Integration Services Team <bsdic@microsoft.com>. BSD
September 10, 2013 BSD
All times are GMT -4. The time now is 01:01 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy