09-15-2008
Yes, it should work. If moving system drives you'll have to rebuild the OS, but as far as I can remember the systems use compatible SCSI types.
10 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
Hi
How do I check how many disks do I have in Solaris & HP-UX?
Also what does this mean
c9t1d5 in /dev/dsk
what is c, t, d etc
cheers (8 Replies)
Discussion started by: g-e-n-o
8 Replies
2. UNIX for Dummies Questions & Answers
Hello
I've been working on AIX 5.3 ML3 on IBM pSeries520. That server has 6 HDD drives in 3 volume groups (1+mirror in each group). I must check which phisical disk is which disk in the system. For ex. I want to know that disk in 4th slot in the machine is marked as hdisk5 on AIX. Does anybody... (2 Replies)
Discussion started by: piooooter
2 Replies
3. AIX
Hi
Is it possible to install in p5 and pSeries SCSI Disks from SUN on DELL? Will they work?
Regards,
Pit (0 Replies)
Discussion started by: piooooter
0 Replies
4. Solaris
I was just curious if anyone has a good tutorial or some info about how I can create and add an array of disks to solaris 8 (11 Replies)
Discussion started by: BRaider
11 Replies
5. Solaris
What are y'all using to wipe your solaris disks?
I am being question by IT Security, what I am using to wipe disk.
Is anyone using a 3rd party utility?
I have used the format utility in solaris previously.
But they are looking for something commercial that I can use.
Anyone have... (4 Replies)
Discussion started by: BG_JrAdmin
4 Replies
6. AIX
hay
I'm new in the AIX-environment. Right now i'm testing some stuff out. But i can't test the LVM-part which is (to me) very important. I have 2 disks in my testmachine but it seems only 1 is working wel. I'll show you the output below of the disks...
hdisk0 = in good condition
hdisk2 =... (8 Replies)
Discussion started by: kvanelshocht
8 Replies
7. Solaris
whats the command to find name of all disks. Is it iostat -En ? (1 Reply)
Discussion started by: vikashtulsiyan
1 Replies
8. Solaris
Have a V440 server which we need to connect up to a SE6140. Did the zoning on the 3900 brocade silkworm and did mapping from the array to the host manually host initiator did not autodetect the wwn and had to key in manually. probe-scsi-all cannot show the fc disks. What is the problem here? (7 Replies)
Discussion started by: incredible
7 Replies
9. Filesystems, Disks and Memory
Dear Friends,
I would like know what are FC related disks and how it will be viewed by generic OSes (Unix, Unix like, Windows & etc.)
AFAIK it is viewed by generic OS as SCSI.
Can we have FC related disks as internal storage(physically) of general purpose machine (Server / PC /... (1 Reply)
Discussion started by: Tlogine
1 Replies
10. Solaris
Hello,
Does anyone know how I can tell what disk are being not being used by a zpool?
For example in Veritas Volume manager, I can run a "vxdisk list" and disks that are marked as "online invalid" are disk that are not used.
I'm looking for a similar command in ZFS which will easily show... (5 Replies)
Discussion started by: robertinoau
5 Replies
LEARN ABOUT FREEBSD
mlxcontrol
MLXCONTROL(8) BSD System Manager's Manual MLXCONTROL(8)
NAME
mlxcontrol -- Mylex DAC-family RAID management utility
SYNOPSIS
mlxcontrol <command> [args]
mlxcontrol status [-qv] [drive]
mlxcontrol rescan controller [controller ...]
mlxcontrol detach drive [drive ...]
mlxcontrol detach -a
mlxcontrol check drive
mlxcontrol config controller
mlxcontrol help command
DESCRIPTION
The mlxcontrol utility provides status monitoring and management functions for devices attached to the mlx(4) driver.
Controller names are of the form "mlxN" where N is the unit number of the controller. Drive names are of the form "mlxdN" where N is the
unit number of the drive. Do not specify the path to a device node.
status Print the status of controllers and system drives. If one or more drives are specified, only print information about these drives,
otherwise print information about all controllers and drives in the system. With the -v flag, display much more verbose informa-
tion. With the -q flag, do not print any output. This command returns 0 if all drives tested are online, 1 if one or more drives
are critical and 2 if one or more are offline.
rescan Rescan one or more controllers for non-attached system drives (e.g. drives that have been detached or created subsequent to driver
initialisation). If the -a flag is supplied, rescan all controllers in the system.
detach Detach one or more system drives. Drives must be unmounted and not opened by any other utility for this command to succeed. If the
-a flag is supplied, detach all system drives from the nominated controller.
check Initiate a consistency check and repair pass on a redundant system drive (e.g. RAID1 or RAID5). The controller will scan the system
drive and repair any inconsistencies. This command returns immediately; use the status command to monitor the progress of the
check.
rebuild Requires two arguments, controller and physdrive as specified in the output of the status command. All system drives using space on
the physical drive physdrive are rebuilt, reconstructing all data on the drive. Note that each controller can only perform one
rebuild at a time. This command returns immediately; use the status command to monitor the progress of the rebuild.
config Print the current configuration from the nominated controller. This command will be updated to allow addition/deletion of system
drives from a configuration in a future release.
help Print usage information for command.
AUTHORS
The mlxcontrol utility was written by Michael Smith <msmith@FreeBSD.org>.
BUGS
The config command does not yet support modifying system drive configuration.
Error log extraction is not yet supported.
BSD