Operating Systems Solaris PLOGI failed state=Packet Transport error Post 302235589 by DukeNuke2 on Friday 12th of September 2008 09:01:20 AM
Old 09-12-2008
maybe one of the gbics has degraded power... and you have to change them. all in all it looks lieke a hardware error.

lets have a look at the output of some commands.

- fcinfo hba-port
- iostat -eE
- luxadm -e port
 

10 More Discussions You Might Find Interesting

1. HP-UX

Error: XDMCP timed out. State=4 (CollectBroadcastQuery)

Hello, I am a new member of this forum. I am trying to solve a following problem with CDE in HPUX 11. The error is Error: XDMCP timed out. State=4 (CollectBroadcastQuery). I have uncommented the following lines from the Xaccess file - * grant service to all remote displays * ... (0 Replies)
Discussion started by: shad
0 Replies

2. Solaris

Unable to bring a disk from error to online state.

Hello experts. I am using Solaris 10(2005) on intel machine. I have installed Veritas Volume manager 5.0. I am unable to bring a disk error to online state. I would like to bring that disk to CDS format. Commands i used and output are.... #vxdisk list DEVICE TYPE ... (11 Replies)
Discussion started by: younus_syed
11 Replies

3. UNIX for Advanced & Expert Users

Transport Error

Dear Friends, I am using Solaris 10 on Sun Sparc T5120 with 4 HDD(Raid).I am getting transport error in one of my mirrored HDD c1t2d0. Below is a screen shot. I have replaced the HDD with new one but still the same. Any one can help???? c1t2d0 Soft Errors: 0 Hard Errors: 0... (1 Reply)
Discussion started by: solaris5.10
1 Replies

4. Solaris

Cygwin X Server error: xdmcp fatal error session failed session 23 failed for display

Hi, i got the following error when i tried to access the cygwin x server from a windows XP PC. "xdmcp fatal error session failed session 23 failed for display" Alternatively, when i tried to access the same Cygwin X Server from another windows XP PC which is on a different LAN... (3 Replies)
Discussion started by: HarishKumarM
3 Replies

5. UNIX for Advanced & Expert Users

sftp error:- Couldn't send packet: Broken pipe

Hi, I am trying to sftp a large file(appx. 2 GB size) from solaris 10 to a Linux server. While sftping(with no options), connection is terminated after some time with broken pipe error. sftp with option -R1 or -B1500 is successful. Linux server ssh Version: OpenSSH_3.9p1, OpenSSL 0.9.7a... (3 Replies)
Discussion started by: brij123
3 Replies

6. Solaris

RED State Exception error in V250

hi all i am getting following error while starting V250 server on console we are not able to go to OBP also. RED State Exception Error enable reg: 0000.0000.0000.0000 CPU 0000.0000.0000.0001 AFSR 0030.02ae.18c0.00b7 Multiple PRIV UCU CPU WDU EDU U E CE FRC FRU (2 Replies)
Discussion started by: nikhil kasar
2 Replies

7. AIX

Open firmware state to running state

Hi Admins, I am having a whole system lpar in open firmware state on HMC. How can I bring it to running state ? Let me know. Thanks. (2 Replies)
Discussion started by: snchaudhari2
2 Replies

8. AIX

Packet loss coming with big packet size ping

(5 Replies)
Discussion started by: Vishal_dba
5 Replies

9. Shell Programming and Scripting

Solaris ping report failed packet script

Hello, on Solaris ping command does not report failed packet as in i.e. Windows (Connection timeout) Instead it reports the sequence of the sent packet: 64 bytes from 10.80.4.120: icmp_seq=11. time=36.0 ms 64 bytes from 10.80.4.120: icmp_seq=12. time=35.9 ms 64 bytes from 10.80.4.120:... (6 Replies)
Discussion started by: drbiloukos
6 Replies

10. AIX

Error received when I was trying to check state of boot record

Hello, This is a test/lab LPAR. Recently installed and updated the SP/TL. everything seems to be working fine. (ran all post install checks) I checked the state of boot record, received the following error/failed message. Can you please explain what does this mean ? />ipl_varyon -i ... (1 Reply)
Discussion started by: dio34
1 Replies
POWERMAN-PDU(8) 						    NUT Manual							   POWERMAN-PDU(8)

NAME
powerman-pdu - Driver for Powerman PDU SYNOPSIS
powerman-pdu -h powerman-pdu -a PDU_NAME [OPTIONS] Note This man page only documents the hardware-specific features of the powerman-pdu driver. For information about the core driver, see nutupsdrv(8). SUPPORTED HARDWARE
This driver supports a wide range of PDUs through the Powerman project. This includes various models from APC, Baytech, Cyclades, but also support IPMI and various blade management modules from HP, IBM and Sun. EXTRA ARGUMENTS
This driver doesn't support any optional settings. INSTALLATION
This driver is not built by default. You can build it by using "configure --with-powerman=yes". UPS COMMANDS
The following instant commands (see upscmd(8)) are available for each outlet of the PDU, with X standing for the outlet number: outlet.X.load.on Power on the outlet. outlet.X.load.off Power off the outlet. outlet.X.load.cycle Cycle the outlet (power off then power on, possibly with a delay). IMPLEMENTATION
The hostname of the Powerman server is specified using the "port" value in ups.conf, i.e.: [pdu] driver = powerman-pdu port = host.example.com:port The port used to reach powermand is optional if the default port is used. KNOWN ISSUES
In the current NUT version (2.4.1), ups.status is still exposed, with the value "WAIT". Some other values from the ups collection are also exposed. AUTHOR
Arnaud Quette <arnaud.quette@gmail.com> SEE ALSO
The core driver: nutupsdrv(8) Internet resources: The NUT (Network UPS Tools) home page: http://www.networkupstools.org/ The PowerMan home page: http://powerman.sourceforge.net/ Network UPS Tools 05/21/2012 POWERMAN-PDU(8)
All times are GMT -4. The time now is 03:42 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.