Sponsored Content
Operating Systems Solaris State information from fcinfo Post 302215484 by jake_won on Wednesday 16th of July 2008 12:15:14 PM
Old 07-16-2008
State information from fcinfo

Hi,

I'm trying to monitor the status of HBA's using fcinfo. Can someone tell me what other states exist? I've searched everywhere but every single output example from fcinfo command has the "state: online". I'm hoping that there are more states than either online and offline (something like faulty or error).

Thanks
 

9 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

TIME_WAIT state

in TCP, is TIME_WAIT state really essential..!!! (3 Replies)
Discussion started by: sasikanth
3 Replies

2. Solaris

Solaris 10. fcinfo hba-port shows adapter not Found

I understand that fcinfo hba-port should show information(WWN, HBA vendor, etc..) but my result show "No adapter found". If I used grep -i 'version' /var/adm/messages* then I see my installed HBA (QLogic FCode at 2.00.09).. I am wondering why and what I had failed to install? Thanks in advance.... (23 Replies)
Discussion started by: Y4Net
23 Replies

3. Solaris

Zone in down state.

One of my zone is stuck in down state, not able to boot it or halt it .. not even detach .. is there any way to recover without rebooting the whole system ( global zone ) ? (3 Replies)
Discussion started by: fugitive
3 Replies

4. Solaris

What update level included fcinfo?

Hi all first post here. quick question what Solaris 10 update level included this utility? I have a bunch of Sun boxes at varying levels of Solaris 10 some have it some do not. When I do my install I take the full option for the packages to install on all the systems. thanks in advance... Mike (4 Replies)
Discussion started by: mike_243us
4 Replies

5. UNIX for Advanced & Expert Users

which C-state governor is in use

How can one know which C-state governor is being used by the system ? Also I'm interested to know what is the procedure to change the C-state governor , say from ladder to menu governor ? :confused: (0 Replies)
Discussion started by: vishwamitra
0 Replies

6. Solaris

Few things related to HBA port & fcinfo command

Hi Gurus I need to know few things related to HBA port & fcinfo command I have a server where there are 4 HBA ports cards are their. Out of 4 ports 2 are in use & 2 are not in use when I check it physicall. Now I want to know the command through which I can get information about all above... (6 Replies)
Discussion started by: girish.batra
6 Replies

7. Red Hat

Information About Solid State Disk in Linux

Hello, I have few HDD and SSD installed in my RHEL 5 server. I want to know which disk are SDD and which are HDD. What command should I use? Thanks (3 Replies)
Discussion started by: fahdmirza
3 Replies

8. UNIX for Advanced & Expert Users

When a process will go to 'D' state?

I'm using "Linux hostname 2.6.28-15-generic #49-Ubuntu SMP Tue Aug 18 18:40:08 UTC 2009 i686 GNU/Linux" All the client machines will use Thin-client ,I will use my laptop for working and I will mount my home directory from server to my laptop. If I open the firefox in my laptop the... (1 Reply)
Discussion started by: ungalnanban
1 Replies

9. AIX

Open firmware state to running state

Hi Admins, I am having a whole system lpar in open firmware state on HMC. How can I bring it to running state ? Let me know. Thanks. (2 Replies)
Discussion started by: snchaudhari2
2 Replies
scstat(1M)						  System Administration Commands						scstat(1M)

NAME
scstat - monitor the status of a Sun Cluster configuration SYNOPSIS
scstat [-DWginpqv [v]] [-h node] DESCRIPTION
Note - Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor- mation about the object-oriented command set, see the Intro(1CL) man page. The scstat command displays the current state of Sun Cluster components. Only one instance of the scstat command needs to run on any machine in the Sun Cluster configuration. When run without any options, scstat displays the status for all components of the cluster. This display includes the following informa- tion: o A list of cluster members o The status of each cluster member o The status of resource groups and resources o The status of every path on the cluster interconnect o The status of every disk device group o The status of every quorum device o The status of every IP network multipathing (IPMP) group and public network adapter From a non-global zone, referred to simply as a zone, you can run all forms of this command except the -i option. When you run the scstat command from a non-global zone, the output is the same as when run from the global zone except that no status information is displayed for IP network multipathing groups or public network adapters. You need solaris.cluster.device.read, solaris.cluster.transport.read, solaris.cluster.resource.read, solaris.cluster.node.read, solaris.cluster.quorum.read, and solaris.cluster.system.read RBAC authorization to use this command without options. See rbac(5). Resources and Resource Groups The resource state, resource group state, and resource status are all maintained on a per-node basis. For example, a given resource has a distinct state on each cluster node and a distinct status on each cluster node. The resource state is set by the Resource Group Manager (RGM) on each node, based only on which methods have been invoked on the resource. For example, after the STOP method has run successfully on a resource on a given node, the resource's state will be OFFLINE on that node. If the STOP method exits nonzero or times out, then the state of the resource is Stop_failed. Possible resource states include: Online, Offline, Start_failed, Stop_failed, Monitor_failed, Online_not_monitored, Starting, and Stopping. Possible resource group states are: Unmanaged, Online, Offline, Pending_online, Pending_offline, Error_stop_failed, Online_faulted, and Pending_online_blocked. In addition to resource state, the RGM also maintains a resource status that can be set by the resource itself by using the API. The field Status Message actually consists of two components: status keyword and status message. Status message is optionally set by the resource and is an arbitrary text string that is printed after the status keyword. Descriptions of possible values for a resource's status are as follows: DEGRADED The resource is online, but its performance or availability might be compromised in some way. FAULTED The resource has encountered an error that prevents it from functioning. OFFLINE The resource is offline. ONLINE The resource is online and providing service. UNKNOWN The current status is unknown or is in transition. Device Groups Device group status reflects the availability of the devices in that group. The following are possible values for device group status and their descriptions: DEGRADED The device group is online, but not all of its potential primaries (secondaries) are up. For two-node connectivity, this status basically indicates that a stand-by primary does not exist, which means a failure of the primary node will result in a loss of access to the devices in the group. OFFLINE The device group is offline. There is no primary node. The device group must be brought online before any of its devices can be used. ONLINE The device group is online. There is a primary node, and devices within the group are ready for I/O. WAIT The device group is between one status and another. This status might occur, for example, when a device group is going from offline to online. IP Network Multipathing Groups IP network multipathing (IPMP) group status reflects the availability of the backup group and the adapters in the group. The following are possible values for IPMP group status and their descriptions: OFFLINE The backup group failed. All adapters in the group are offline. ONLINE The backup group is functional. At least one adapter in the group is online. UNKNOWN Any other state than those listed before. This could result when an adapter is detached or marked as down by Solaris commands such as if_mpadm or ifconfig. The following are possible values for IPMP adapter status and their descriptions: OFFLINE The adapter failed or the backup group is offline. ONLINE The adapter is functional. STANDBY The adapter is on standby. UNKNOWN Any other state than those listed before. This could result when an adapter is detached or marked as down by Solaris commands such as if_mpadm or ifconfig. OPTIONS
You can specify command options to request the status for specific components. If more than one option is specified, the scstat command prints the status in the specified order. The following options are supported: -D Shows status for all disk device groups. You can use this option in the global zone or in a non-global zone. For ease of administration, use this form of the command in the global zone. Output is the same when run from a zone as when run from the global zone. You need solaris.cluster.device.read RBAC authorization to use this command option. See rbac(5). -g Shows status for all resource groups. You can use this option in the global zone or in a non-global zone. For ease of administration, use this form of the command in the global zone. Output is the same when run from a zone as when run from the global zone. You need solaris.cluster.resource.read RBAC authorization to use this command option. See rbac(5). -h node Shows status for the specified node (node) and status of the disk device groups of which this node is the primary node. Also shows the status of the quorum devices to which this node holds reservations of the resource groups to which the node is a potential master, and holds reservations of the transport paths to which the node is attached. You need solaris.cluster.device.read, solaris.cluster.transport.read, solaris.cluster.resource.read, solaris.clus- ter.node.read, solaris.cluster.quorum.read, and solaris.cluster.system.read RBAC authorization to use this command option. See rbac(5). -i Shows status for all IPMP groups and public network adapters. You can use this option only in the global zone. -n Shows status for all nodes. You can use this option in the global zone or in a non-global zone. For ease of administration, use this form of the command in the global zone. Output is the same when run from a zone as when run from the global zone. You need solaris.cluster.node.read RBAC authorization to use this command option. See rbac(5). -p Shows status for all components in the cluster. Use with -v to display more verbose output. You can use this option in the global zone or in a non-global zone. For ease of administration, use this form of the command in the global zone. Output is the same when run from a zone as when run from the global zone, except that no status for IPMP groups or public net- work adapters is displayed. You need solaris.cluster.device.read, solaris.cluster.transport.read, solaris.cluster.resource.read, solaris.clus- ter.node.read, solaris.cluster.quorum.read, and solaris.cluster.system.read RBAC authorization to use -p with -v. See rbac(5). -q Shows status for all device quorums and node quorums. You can use this option in the global zone or in a non-global zone. For ease of administration, use this form of the command in the global zone. Output is the same when run from a zone as when run from the global zone. You need solaris.cluster.quorum.read RBAC authorization to use this command option. See rbac(5). -v[v] Shows verbose output. -W Shows status for cluster transport path. You can use this option in the global zone or in a non-global zone. For ease of administration, use this form of the command in the global zone. Output is the same when run from a zone as when run from the global zone. You need solaris.cluster.transport.read RBAC authorization to use this command option. See rbac(5). EXAMPLES
Example 1 Using the scstat Command The following command displays the status of all resource groups followed by the status of all components related to the specified host: % scstat -g -h host The output that is displayed appears in the order in which the options are specified. These results are the same results you would see by typing the two commands: % scstat -g and % scstat -h host EXIT STATUS
The following exit values are returned: 0 The command completed successfully. nonzero An error has occurred. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWsczu | +-----------------------------+-----------------------------+ |Interface Stability |Evolving | +-----------------------------+-----------------------------+ SEE ALSO
Intro(1CL), cluster(1CL), if_mpadm(1M), ifconfig(1M), scha_resource_setstatus(1HA), scha_resource_setstatus(3HA), attributes(5) NOTES
An online quorum device means that the device was available for contributing to the formation of quorum when quorum was last established. From the context of the quorum algorithm, the device is online because it actively contributed to the formation of quorum. However, an online quorum device might not necessarily continue to be in a healthy enough state to contribute to the formation of quorum when quorum is re-established. The current version of Sun Cluster does not include a disk monitoring facility or regular probes to the quorum devices. Sun Cluster 3.2 10 Jul 2006 scstat(1M)
All times are GMT -4. The time now is 04:44 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy