Sponsored Content
Full Discussion: C with MQ Series
Top Forums Programming C with MQ Series Post 302211221 by Nagapandi on Thursday 3rd of July 2008 01:02:40 AM
Old 07-03-2008
Still struggling with material/code hunting, not yet successful.

Any one could you please help me.

Thanks in Advance,
NagaSmilie
 

9 More Discussions You Might Find Interesting

1. Programming

Ibm Mq Series

hi everybody, My name is Raj i work in GE Global Software Solutions As Siebel Analyst. Can any one help in writing the code in Ansi C on HP-Unix platform to get data from IBM MQ-Series Server. IBM MQ-series client will be installed on the client machine which is on WIN NT platform. And MQ-series... (2 Replies)
Discussion started by: garimella
2 Replies

2. Shell Programming and Scripting

Fibonacci series

Need code to run the Fibonacci series from 0 to 10 (16 Replies)
Discussion started by: nycol
16 Replies

3. Shell Programming and Scripting

print 10 characters in series

suppose fileA kanika123ABC 1222222222222222 raciat5678ty 1221123333331121 jessica78ulllo 2233243223333333 so output shud be print only first 10 characters in series and rest remain same kanika123A 1222222222222222 raciat5678 1221123333331121 jessica78u ... (1 Reply)
Discussion started by: cdfd123
1 Replies

4. Shell Programming and Scripting

problem in fibonacci series

hi, I'm a beginner to UNIX and got some problem in this fibonacci.Please help me out.Here is the code: fibo() { if then fibo=` expr {fibo ($1 - 2)} + {fibo ($1 - 1)}` | bc echo $fibo fi } echo "enter a number:" read x #echo "The fibonnacci series for value $x is:" fibo $x ... (4 Replies)
Discussion started by: janani_kalyan
4 Replies

5. Programming

series of combinations

HI I have a series(sorted), which i require to create combinations. I am not getting the good code for doing this. My series should generate the following combinations... Please help me in getting this in C++. Thanks for your help. A: A A B: A B A B A B C: A ... (1 Reply)
Discussion started by: rameshmelam
1 Replies

6. Shell Programming and Scripting

How to code a series of numbers in SH

Hi. How can I write this in a shorter way? for NUMs in 1 2 3 4 5 6 I looked at the"seq" command, but I do not think that is what I want. Can I code for NUMs (1..7) Hey!! Is that it? (8 Replies)
Discussion started by: Ccccc
8 Replies

7. Solaris

M Series

Hi All, Do anyone know if I upgrade cpu module and memory module for one of the domain inside Sun M5000. After the upgrade, will the hostid for the domain change or it will remain as long we don't change the system board? Currently will try to upgrade one of the Sun M5000 with 4 domains... (2 Replies)
Discussion started by: mailbox80
2 Replies

8. Shell Programming and Scripting

How to get the number series in between?

Hi Guys, Can someone give me a simple script that can extract the numbers in between numbers from start to end. As shown below, it start from 100 to 110 and revealed the numbers in between. INPUT: 100 - 110 DESIRED OUTPUT: 100 101 102 103 104 105 106 107 (6 Replies)
Discussion started by: pinpe
6 Replies

9. Red Hat

Find the series

Hai what command is used to find red hat linux 5 series? (2 Replies)
Discussion started by: vinayd
2 Replies
BCMXCP(8)							    NUT Manual								 BCMXCP(8)

NAME
bcmxcp - Driver for UPSes supporting the serial BCM/XCP protocol NOTE
This man page only documents the hardware-specific features of the bcmxcp driver. For information about the core driver, see nutupsdrv(8). SUPPORTED HARDWARE
This driver should recognize all serial BCM/XCP-compatible UPSes. It has been developed and tested on Powerware PW5115 and PW9120 hardware. If your UPS has a USB connection, you may also consult the bcmxcp_usb(8) driver documentation. EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5). shutdown_delay=delay The number of seconds that the UPS should wait between receiving the shutdown command (upsdrvctl shutdown) and actually shutting off. baud_rate=rate Communication speed for the UPS. If this is set to 9600, it tries to connect to the UPS at 9600bps. If it fails to communicate, it will go into baud-hunting. It starts at 1200 and goes up to 19200. If it succeeds, it tell you the speed it connected with. If not included in the config, it defaults to baud-hunting. DEFAULT VALUES FOR THE EXTRA ARGUMENTS
o shutdown_delay = 120 o baud_rate = none INSTANT COMMANDS
This driver supports the following Instant Commands: shutdown.return Turn off the load and return when power is back. shutdown.stayoff Turn off the load and remain off. test.battery.start Start a battery test. outlet.n.shutdown.return Turn off the load on outlet n and return when power is back. (n is the outlet number reported by the upsc command) TODO LIST
Report UPS statistics information BCM/XCP supports reporting of UPS statistics data. Change settings Access the config register to change settings. BUGS
None known. AUTHOR
Tore Orpetveit <tore@orpetveit.net> SEE ALSO
The core driver: nutupsdrv(8) The USB BCM/XCP driver: bcmxcp_usb(8) Internet resources: The NUT (Network UPS Tools) home page: http://www.networkupstools.org/ Network UPS Tools 05/21/2012 BCMXCP(8)
All times are GMT -4. The time now is 12:36 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.