Sponsored Content
Full Discussion: vpar ignite
Operating Systems HP-UX vpar ignite Post 302207570 by mahlathini on Friday 20th of June 2008 09:17:14 AM
Old 06-20-2008
vpar ignite

Hi

Can I use a vpar as an ignite server?
 

10 More Discussions You Might Find Interesting

1. HP-UX

Need Ignite for HP-UX 10.20

Hello All, I need to bring down our old 9000 series d350, but my supervisor wants an ignite backup created. I cannot find ignite in the usual places (/opt/ignite) nor can I find it in swlist. As far as I can tell the cd's are long gone. Is there anywhere else I could look for ignite being... (6 Replies)
Discussion started by: stay0ut
6 Replies

2. HP-UX

Ignite and HP-UX 09.XX

I am looking to make bootable tape backups of four machines running HP-UX 09.02, 09.05 and 09.07. I successfully located Ignite 10.20 and installed it and made a backup on the one machine running HP-UX 10.20. I am having trouble locating information about Ignite for HP-UX 9. Does it exist? Is... (3 Replies)
Discussion started by: whack_job
3 Replies

3. HP-UX

Ignite - make_net_recovery

I've read the Ignite User/Admin Guide but I'm having trouble figuring out if I can do a make_net_recovery if the ignite server and client server are on completely different networks? If this can be done is there any special configuration? If I initiate the command from the server it looks like it... (3 Replies)
Discussion started by: gonzotonka
3 Replies

4. HP-UX

vPar Hardware Paths

I wonder if anyone could assist with this. We have taken over administration of an rp8440 that has been split into 2 nPars and has 4vPars per nPar. I have to add a network card into one of the vPars that was missed at the time the vPar was created. That bit i have no problem with. The... (0 Replies)
Discussion started by: Andyp2704
0 Replies

5. HP-UX

vPar Boot Error

Hi All, Please help me out in below issue in creating vPar. We have one nPar in which we have to create 2 vPars, out of which first vPar is already created and it is running well which have local disk as a boot device.Now we have to create 2nd vPar which need to use SAN disk for booting.... (3 Replies)
Discussion started by: laxmikant
3 Replies

6. HP-UX

Error with ignite

Works all. Depot shared via nfs dhcp working setting file system,network,root password,etc But when i start "go!" with installation,give me this error. How to fix,debug? Thanks http://s24.postimg.org/5hzbgk551/unixbell3.png (3 Replies)
Discussion started by: Linusolaradm1
3 Replies

7. HP-UX

VPar hardware migration - ERRATA document

Hi guys, I'm moving some vPars from BL860c I2 and BL870c I2 using the DRD clone and relocation. In some case, as instance to upgrade to BL870c I2, the ERRATA document reports some additional driver to be added to the image made by the DRD and then recompile the kernel before the move to the... (0 Replies)
Discussion started by: cecco16
0 Replies

8. HP-UX

VPAR Resource Capacity Limit

Hello Guys Could you please let me know the command to find the resource (vCPU & Memory) capacity limit for the VPAR's (HPUX 11.23) on integrity Virtual host servers running HPUX 11.31 OS. For eg. I want to know what is the max vCPU and memory that I can assign to one VPAR. The Base Virtual... (0 Replies)
Discussion started by: prvnrk
0 Replies

9. HP-UX

How to shutdown a vpar from another vpar?

Hi, How can I shutdown a vpar from another vpar ? Please provide the command. Thanks. (0 Replies)
Discussion started by: snchaudhari2
0 Replies

10. HP-UX

Ignite

Hi Does anybody know how to get hold of a very old (A.3.7.n) copy of the ignite software depot for HP-UX 10.20? (7 Replies)
Discussion started by: gregsih
7 Replies
vparefiutil(1M) 														   vparefiutil(1M)

NAME
vparefiutil - display, update, or delete HP-UX hardware path to EFI path mappings of bootable disks in the virtual partition database SYNOPSIS
db_file] hw_path] DESCRIPTION
The command displays the HP-UX hardware path to EFI path mappings that are stored in the virtual partition database. Legacy and agile hardware paths will be displayed, if available, as provided by HP-UX. If the virtual partition database is not specified, then the live database or by default is used. It can also be used to update the hw_path to EFI_path mappings from to the database. The behavior without any options is to display the HP-UX hardware path to EFI path mappings. This command is not supported on PA-RISC systems. Options and Arguments recognizes the following command line options and arguments: Specifies the alternate database from which the HP-UX hardware path to EFI path mappings need to be displayed, updated, or deleted. or live is default if this is not specified. Updates the database from the info available (from Displays the HP-UX hardware path to EFI path mapping in machine readable format. Each mapping is displayed in a separate line as follows: Deletes the HP-UX hardware path to EFI path mappings in the database. Note: In live database, this deletes only the HP-UX hardware paths owned by the vpar on which this command is executed. If this is specified, only the HP-UX hardware paths at or below the given hw_path are displayed, updated, or deleted. SECURITY RESTRICTIONS
This command is restricted to processes owned by superuser. RETURN VALUE
returns the following values: Successful completion. Error condition occurred. EXAMPLES
Display the hw_path to EFI_path mappings from the live database. # vparefiutil Hardware path - EFI path mapping ================================ Hardware path : 2.0.0.2.0.6.0 : 2.0.0.2.0.6.0 EFI path : Acpi(HWP0002,200)/Pci(2|0)/Scsi(Pun6,Lun0)/EFIHPUXHPUX.EFI Hardware path : 2.0.0.3.0.6.0 : 2.0.0.3.0.6.0 EFI path : Acpi(HWP0002,200)/Pci(3|0)/Scsi(Pun6,Lun0)/ HD(Part1,Sig471031FC-6A12-11D9-8002-D6217B60E588)/EFIHPUXHPUX.EFI Hardware path : 2.0.0.3.1.2.0 : 2.0.0.3.1.2.0 EFI path : Acpi(HWP0002,200)/Pci(3|1)/Scsi(Pun2,Lun0)/EFIHPUXHPUX.EFI Hardware path : 2.0.8.1.0.3.4.0.0.1.6 : 2.0.8.1.0.0x50001fe1500339ed.0x1000000000000 EFI path : Acpi(HWP0002,28C)/Pci(1|0)/Pci(4|0)/ Fibre(WWN50001FE1500339ED,Lun1000000000000)/ HD(Part1,Sig9FEF4B40-6AC7-11D9-8002-D6217B60E588)/EFIHPUXHPUX.EFI Hardware path : 2.0.12.1.0.4.1.8.0 : EFI path : Acpi(HWP0002,2C6)/Pci(1|0)/Pci(4|1)/Scsi(Pun8,Lun0)/ HD(Part1,Sig00F95EE2-66C4-11D9-8002-D6217B60E588)/EFIHPUXHPUX.EFI Hardware path : 2.0.12.1.0.4.1.10.0 : EFI path : Acpi(HWP0002,2C6)/Pci(1kk0)/EFIHPUXHPUX.EFI Hardware path : 2.0.12.1.0.4.1.12.0 : EFI path : Acpi(HWP0002,2C6)/Pci(1|0)/Pci(4|1)/Scsi(PunC,Lun0)/ HD(Part1,Sig4D70B9D6-6AD5-11D9-8002-D6217B60E588)/EFIHPUXHPUX.EFI # vparefiutil Hardware path - EFI path mapping ================================ Hardware path : 2.0.0.2.0.6.0 : EFI path : Acpi(HWP0002,200)/Pci(2|0)/Scsi(Pun6,Lun0)/EFIHPUXHPUX.EFI Hardware path : 2.0.0.3.0.6.0 : EFI path : Acpi(HWP0002,200)/Pci(3|0)/Scsi(Pun6,Lun0)/ HD(Part1,Sig471031FC-6A12-11D9-8002-D6217B60E588)/EFIHPUXHPUX.EFI Hardware path : 2.0.0.3.1.2.0 : EFI path : Acpi(HWP0002,200)/Pci(3|1)/Scsi(Pun2,Lun0)/EFIHPUXHPUX.EFI Hardware path : 2.0.8.1.0.3.4.0.0.1.6 : 2.0.8.1.0.0x50001fe1500339ed.0x1000000000000 EFI path : Acpi(HWP0002,28C)/Pci(1|0)/Pci(4|0)/ Fibre(WWN50001FE1500339ED,Lun1000000000000)/ HD(Part1,Sig9FEF4B40-6AC7-11D9-8002-D6217B60E588)/ EFIHPUXHPUX.EFI Hardware path : 2.0.12.1.0.4.1.8.0 : EFI path : Acpi(HWP0002,2C6)/Pci(1|0)/Pci(4|1)/Scsi(Pun8,Lun0)/ HD(Part1,Sig00F95EE2-66C4-11D9-8002-D6217B60E588)/EFIHPUXHPUX.EFI Hardware path : 2.0.12.1.0.4.1.10.0 : EFI path : Acpi(HWP0002,2C6)/Pci(1kk0)/EFIHPUXHPUX.EFI Hardware path : 2.0.12.1.0.4.1.12.0 : EFI path : Acpi(HWP0002,2C6)/Pci(1|0)/Pci(4|1)/Scsi(PunC,Lun0)/ HD(Part1,Sig4D70B9D6-6AD5-11D9-8002-D6217B60E588)/EFIHPUXHPUX.EFI Display the hw_path to EFI_path mappings from the alternate database in machine readable format. # vparefiutil -M -D vpdb_foo 2.0.0.2.0.6.0:Acpi(HWP0002,200)/Pci(2|0)/Scsi(Pun6,Lun0)/EFIHPUXHPUX.EFI::2.0.0.2.0.6.0 2.0.0.3.0.6.0:Acpi(HWP0002,200)/Pci(3|0)/ Scsi(Pun6,Lkk6A12-11D9-8002-D6217B60E588)/EFIHPUXHPUX.EFI::2.0.0.3.0.6.0 2.0.0.3.1.2.0:Acpi(HWP0002,200)/Pci(3|1)/Scsi(Pun2,Lun0)/EFIHPUXHPUX.EFI::2.0.0.3.1.2.0 2.0.8.1.0.3.4.0.0.1.6:Acpi(HWP0002,28C)/Pci(1|0)/Pci(4|0)/ Fibre(WWN50001FE1500339ED,Lun1000000000000)/ HD(Part1,Sig9FEF4B40-6AC7-11D9-8002-D6217B60E588)/ EFIHPUXHPUX.EFI::2.0.8.1.0.0x50001fe1500339ed.0x1000000000000 2.0.12.1.0.4.1.8.0:Acpi(HWP0002,2C6)/Pci(1|0)/Pci(4|1)/Scsi(Pun8,Lun0)/ HD(Part1,Sig00F95EE2-66C4-11D9-8002-D6217B60E588)/EFIHPUXHPUX.EFI:: 2.0.12.1.0.4.1.10.0:Acpi(HWP0002,2C6)/Pci(1|0)/Pci(4|1)/Scsi(PunA,Lun0)/ EFIHPUXHPUX.EFI:: 2.0.12.1.0.4.1.12.0:Acpi(HWP0002,2C6)/Pci(1|0)/Pci(4|1)/Scsi(PunC,Lun0)/ HD(Part1,Sig4D70B9D6-6AD5-11D9-8002-D6217B60E588)/EFIHPUXHPUX.EFI:: # vparefiutil -M -D vpdb_foo 2.0.0.2.0.6.0:Acpi(HWP0002,200)/Pci(2|0)/Scsi(Pun6,Lun0)/EFIHPUXHPUX.EFI:: 2.0.0.3.0.6.0:Acpi(HWP0002,200)/Pci(3|0)/ Scsi(Pun6,Lkk6A12-11D9-8002-D6217B60E588)/EFIHPUXHPUX.EFI:: 2.0.0.3.1.2.0:Acpi(HWP0002,200)/Pci(3|1)/Scsi(Pun2,Lun0)/EFIHPUXHPUX.EFI:: 2.0.8.1.0.3.4.0.0.1.6:Acpi(HWP0002,28C)/Pci(1|0)/Pci(4|0)/ Fibre(WWN50001FE1500339ED,Lun1000000000000)/ HD(Part1,Sig9FEF4B40-6AC7-11D9-8002-D6217B60E588)/ EFIHPUXHPUX.EFI::2.0.8.1.0.0x50001fe1500339ed.0x1000000000000 2.0.12.1.0.4.1.8.0:Acpi(HWP0002,2C6)/Pci(1|0)/Pci(4|1)/Scsi(Pun8,Lun0)/ HD(Part1,Sig00F95EE2-66C4-11D9-8002-D6217B60E588)/EFIHPUXHPUX.EFI:: 2.0.12.1.0.4.1.10.0:Acpi(HWP0002,2C6)/Pci(1|0)/Pci(4|1)/ Scsi(PunA,Lun0)/EFIHPUXHPUX.EFI:: 2.0.12.1.0.4.1.12.0:Acpi(HWP0002,2C6)/Pci(1|0)/Pci(4|1)/Scsi(PunC,Lun0)/ HD(Part1,Sig4D70B9D6-6AD5-11D9-8002-D6217B60E588)/EFIHPUXHPUX.EFI:: Delete the HP-UX hardware-path paths to EFI path mappings at or below the HP-UX hardware path 2/0/0/3 of the current vpar. # vparefiutil -d -H 2/0/0/3 # vparefiutil Hardware path - EFI path mapping ================================ Hardware path : 2.0.0.2.0.6.0 : EFI path : Acpi(HWP0002,200)/Pci(2|0)/Scsi(Pun6,Lun0)/EFIHPUXHPUX.EFI Hardware path : 2.0.8.1.0.3.4.0.0.1.6 : 2.0.8.1.0.0x50001fe1500339ed.0x1000000000000 EFI path : Acpi(HWP0002,28C)/Pci(1|0)/Pci(4|0)/ Fibre(WWN50001FE1500339ED,Lun1000000000000)/ HD(Part1,Sig9FEF4B40-6AC7-11D9-8002-D6217B60E588)/EFIHPUXHPUX.EFI Hardware path : 2.0.12.1.0.4.1.8.0 : EFI path : Acpi(HWP0002,2C6)/Pci(1|0)/Pci(4|1)/Scsi(Pun8,Lun0)/ HD(Part1,Sig00F95EE2-66C4-11D9-8002-D6217B60E588)/EFIHPUXHPUX.EFI Hardware path : 2.0.12.1.0.4.1.10.0 : EFI path : Acpi(HWP0002,2C6)/Pci(1|0)/Pci(4|1)/Scsi(PunA,Lun0)/ EFIHPUXHPUX.EFI Hardware path : 2.0.12.1.0.4.1.12.0 : EFI path pdb|0)/Pci(4|1)/Scsi(PunC,Lun0)/ HD(Part1,Sig4D70B9D6-6AD5-11D9-8002-D6217B60E588)/EFIHPUXHPUX.EFI # vparefiutil -d -H 2/0/0/3 # vparefiutil Hardware path - EFI path mapping ================================ Hardware path : 2.0.0.2.0.6.0 : EFI path : Acpi(HWP0002,200)/Pci(2|0)/Scsi(Pun6,Lun0)/EFIHPUXHPUX.EFI Hardware path : 2.0.8.1.0.3.4.0.0.1.6 : 2.0.8.1.0.0x50001fe1500339ed.0x1000000000000 EFI path : Acpi(HWP0002,28C)/Pci(1|0)/Pci(4|0)/ Fibre(WWN50001FE1500339ED,Lun1000000000000)/ HD(Part1,Sig9FEF4B40-6AC7-11D9-8002-D6217B60E588)/EFIHPUXHPUX.EFI Hardware path : 2.0.12.1.0.4.1.8.0 : EFI path : Acpi(HWP0002,2C6)/Pci(1|0)/Pci(4|1)/Scsi(Pun8,Lun0)/ HD(Part1,Sig00F95EE2-66C4-11D9-8002-D6217B60E588)/EFIHPUXHPUX.EFI Hardware path : 2.0.12.1.0.4.1.10.0 : EFI path : Acpi(HWP0002,2C6)/Pci(1|0)/Pci(4|1)/ Scsi(PunA,Lun0)/EFIHPUXHPUX.EFI Hardware path : 2.0.12.1.0.4.1.12.0 : EFI path pdb|0)/Pci(4|1)/Scsi(PunC,Lun0)/ HD(Part1,Sig4D70B9D6-6AD5-11D9-8002-D6217B60E588)/EFIHPUXHPUX.EFI For Serial Attach SCSI (SAS) devices, the SAS address is displayed along with the hardware path and the EFI path. Hardware path : 0.0.14.0.0.0.0.0.0.2.0 EFI path : Acpi(HPQ0002,PNP0A08,E)/Pci(0|0)/Pci(0|0)/ VenMsg(D487DDB4-008B-11D9-AFDC-001083FFCA4D)/ HD(Part1,SigC6B41C20-01BE-11DC-8000-D6217B60E588)/EFIHPUXHPUX.EFI SAS Address : 0x500000e01200d3f2 The SAS hardware path can potentially change from one OS instance to another, but the SAS address will remain the same. To locate SAS devices in different OS instances (for example, an nPar OS instance and a vPar OS instance), use the SAS address instead of the hardware path. WARNING
The option is provided only to remove the stale HP-UX hardware path to EFI path mappings. If you remove the valid HP-UX hardware path to EFI path mappings, you may not be able to load vpars. It is always better to follow the operation with a operation to update the database with the valid HP-UX hardware path to EFI path mappings available from AUTHOR
was developed by the Hewlett-Packard Company. SEE ALSO
vparadmin(1M), vparboot(1M), vparconfig(1M), vparcreate(1M), vpardump(1M), vparenv(1M), vparextract(1M), vparmodify(1M), vparreloc(1M), vparremove(1M), vparreset(1M), vparstatus(1M), vparutil(1M), privileges(5), vparresources(5), vpartition(5), vpmon(5). Itanium(R)-Based Systems vparefiutil(1M)
All times are GMT -4. The time now is 01:35 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy