Sponsored Content
Full Discussion: cfgmgr
Operating Systems AIX cfgmgr Post 302206929 by itik on Wednesday 18th of June 2008 05:23:29 PM
Old 06-18-2008
cfgmgr

Hi All,

I remember my old senior mentor in AIX that cfgmgr should not be terminated on your console. Because if it's terminated in the middle, the odm might get corrupted.

Is that true for AIX 5.x?

Regards,
itik
 

8 More Discussions You Might Find Interesting

1. AIX

LPAR and CFGMGR

I have a P570 that for some reason is not allowing the P1-T6 NIC to be recognized. I have confirmed from the HMC that it is set for the LPAR, but when I do a cfgmgr, it won't recognize it. It though is recognizing the slot cards just fine which are P1-C3 for one shelf and P1-C3 of another shelf.... (1 Reply)
Discussion started by: LegendMan
1 Replies

2. AIX

cfgmgr and hdisk number allocation

Hi - can anybody tell me what the default behaviour is for cfgmgr when it allocates hdisk numbers to newly discovered disks in the ODM ? I want to add a disk from our FAStT700 SAN disk array and import it on our p-series (AIX 5.2). Problem is we import and export Flashcopy devices fror scripted... (5 Replies)
Discussion started by: fosteria
5 Replies

3. AIX

cfgmgr: Filesets missing

Hi all, I have a System i server with a couple of AIX LPARs. One of the LPARs owns a dual-channel scsi adapter to which I connect a tape library (IBM TS3100) and a DVD Drive. I had some problems to get the Tape Library detected but finally I got it: rmt0 Available 03-08-01-4,0 IBM 3580... (1 Reply)
Discussion started by: wendelalexis
1 Replies

4. AIX

Dual port NIC, cfgmgr

OS: AIX 6.1 The host has a dual port NIC installed and when I went to run `cfgmgr -v` to configure it I got an error showing device packages are missing from the install: `cfgmgr -v` on 10.15.xx.xxx cfgmgr: 0514-621 WARNING: The following device packages are required for device support but... (3 Replies)
Discussion started by: b1f30
3 Replies

5. AIX

cfgmgr in my aix box

Hi When I run cfgmgr -v in my aix box I get the below error : cfgmgr: 0514-621 WARNING: The following device packages are required for device support but are not currently installed. devices.loopback My oslevel is 6100-06-02-1044 Please assist. Please use and tags when... (3 Replies)
Discussion started by: samsungsamsung
3 Replies

6. AIX

cfgmgr: 0514-621 WARNING

Dear all i have a sun SL500 tape library attached to my AIX box while issue the command cfgmgr i have the below issue test>cfgmgr cfgmgr: 0514-621 WARNING: The following device packages are required for device support but are not currently installed. devices.fcp.changer please... (3 Replies)
Discussion started by: thecobra151
3 Replies

7. AIX

Time taking for cfgmgr on dual VIO

Hi, From the man page, cfgmgr configures devices and optionally installs device software by running the programs specified in the Configuration Rules object class and it is not dependent on platform . Are there any fundamental differences impacting the speed of cfgmgr on a stand-alone and... (5 Replies)
Discussion started by: Sachin1987
5 Replies

8. Post Here to Contact Site Administrators and Moderators

Cfgmgr Error

Hi, My AIX server able to detect the LUN's which is mapped from IBM v7k storage, And i allocated one more LUN from HP storage but it's appear two hdisk instead of one and it's showing incorrect LUN ID. SDDPCM driver already installed on this server. During cfgmgr, Im getting this message :... (1 Reply)
Discussion started by: xinuadmin
1 Replies
cfg_subsys_attr_t(9s)													     cfg_subsys_attr_t(9s)

NAME
cfg_subsys_attr_t - General: Contains attribute information for kernel modules SYNOPSIS
typedef struct { char name[CFG_ATTR_NAME_SZ]; uchar type; uchar operation; caddr_t addr; ulong min_val; ulong max_val; ulong val_size; } cfg_subsys_attr_t; MEMBERS
Specifies the ASCII name of the attribute. The name must be between 2 and CFG_ATTR_NAME_SZ characters in length, including the terminating null character. Do not begin the ASCII name of the attribute with the Method_ or Device_ characters. The cfgmgr framework reserves certain names that begin with the Method_ and Device_ characters. Specifies the data type associated with the name attribute. See the DESCRIPTION section for the constants you can pass to the type member. Specifies the operations that the cfgmgr framework can perform on the attribute. See the DESCRIPTION section for the constants you can pass to the operation member. Specifies the address of the data value associated with the attribute. The cfgmgr framework obtains the data value for this attribute from the /etc/sysconfigtab database and stores it at this address. The cfgmgr framework performs this storage operation if the following occurs: The attribute appears in the cfg_subsys_attr_t table (declared and initialized in the kernel module) with an operation code of CFG_OP_CONFIGURE. The kernel module writer passes the CFG_OP_CONFIGURE constant to the optype argument of the kernel module's configure routine. This is the kernel module's configuration entry point for handling static or dynamic configuration requests. Although the configure routine can initialize attributes that appear in the array with an operation code of CFG_OP_CONFIGURE, the cfgmgr framework overrides this initialization with the value specified in the /etc/sysconfigtab database. Specifies the minimum length of a string data value. If the data type for the attribute is numeric, specifies the minimum range. Specifies the maximum length of a string data value. If the data type for the attribute is numeric, specifies the maximum range. Specifies the binary data size. DESCRIPTION
The cfg_subsys_attr_t data structure contains information that kernel modules use to describe a variety of attributes. Kernel module writ- ers declare and initialize an array of cfg_subsys_attr_t data structures in their kernel modules. The cfg_subsys_attr_t data structure is a simplified version of the cfg_attr_t data structure and is designed to save space in the kernel. You must set the type member to one of the following constants: Data type is a null-terminated array of characters. Data type is a 32-bit signed integer. Data type is a 32-bit unsigned integer. Data type is a 64-bit signed integer. Data type is a 64-bit unsigned integer. Data type is an array of bytes. Data type is an 8-bit unsigned character. Data type is a 16-bit unsigned short integer. You can set the operation member to one of the following constants: The cfgmgr framework configures the attribute. This means the cfgmgr framework obtains a data value for the attribute from the /etc/sysconfigtab database. The configure operation occurs when the cfgmgr frame- work calls the kernel module's configure routine at its CFG_OP_CONFIGURE entry point. (That is, the optype argument of theconfigure rou- tine evaluates to the CFG_OP_CONFIGURE constant.) The cfgmgr framework queries (reads) the attribute. This means the kernel module cooper- ates with the cfgmgr framework to provide the value associated with the attribute as a result of user-initiated query requests. These requests are typically the result of the sysconfig -q command. The query operation occurs when the cfgmgr framework calls the kernel mod- ule's configure routine at its CFG_OP_QUERY entry point. (That is, the optype argument of the configure routine evaluates to the CFG_OP_QUERY constant.) The cfgmgr framework reconfigures the attribute. This means the cfgmgr framework reconfigures the data value for the attribute. This functionality allows a user to modify the attribute. A reconfigure request is typically the result of the sysconfig -r command. The reconfigure operation occurs when the cfgmgr framework calls the kernel module's configure routine at its CFG_OP_RECONFIG- URE entry point. (That is, the optype argument of the configure routine evaluates to the CFG_OP_RECONFIGURE constant.) FILES
SEE ALSO
Data Structures: cfg_attr_t(9s) cfg_subsys_attr_t(9s)
All times are GMT -4. The time now is 05:20 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy