Operating Systems Solaris how to hardware RAID 1 on T5120 Post 302202748 by incredible on Thursday 5th of June 2008 02:09:23 PM
Old 06-05-2008
pull out one of the disk and check if your system is still ok and accessible. check raidctl and it should tell that a controller device as "missing" plug back in the removed disk and synchronization takes place automatically
 

9 More Discussions You Might Find Interesting

1. Solaris

Hardware RAID

I don't understood why on SPARC-Platforms have not present RAID-Controller ? Sorry for my bad english, but it's crazy always setup software RAID !!! I whanna Hardware RAID and when i can find solution ? (7 Replies)
Discussion started by: jess_t03
7 Replies

2. Solaris

T2000 Hardware RAID

Hi, I have a root with hardware RAID on c0t0d0 and c0t2d0. I would like to set the boot device sequence in OBP for both hdds. I have checked in ls -l /dev/rdsk/ for the path of c0t2d0 but it does not exist. Can anyone shed some lights on this? AVAILABLE DISK SELECTIONS: 0.... (12 Replies)
Discussion started by: honmin
12 Replies

3. Solaris

How to destroy hardware raid on T5120

Hi, I have problem creating hardware raid on T5120 with 4 disks. After the hardware raid 1 created, then I used the raidctl -l c1t0d0 and raidctl -l c1t2d0 the output of volume c1t0d0 contain disk 0.0.0 0.1.0, also the volume c1t2d0 contain disk 0.0.0 0.1.0 and should be 0.2.0 0.3.0 so I... (15 Replies)
Discussion started by: netlink
15 Replies

4. Solaris

Sun T5120 hardware RAID question

Hi everyone I've just purchased a Sun T5120 server with 2 internal disks. I've configured hardware RAID (mirror) and as a result the device tree in Solaris only contains 1 hard drive. My question is, how would I know when one of the drives become faulty? Thanks (2 Replies)
Discussion started by: soliberus
2 Replies

5. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

6. Hardware

Sun T3-1 hardware RAID

Hi all I've just received my T3-1. It has 8 disks and I would like to configure RAID1 on the disks. The Sun documentation states that you can either use the OpenBoot PROMP utility called Fcode or you can use software via the Solaris OS. The documentation doesn't make it clear if: 1. The... (6 Replies)
Discussion started by: soliberus
6 Replies

7. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

8. Solaris

Hardware raid patching

Dear All , we have hardware raid 1 implemented on Solaris Disks. We need to patch the Servers. Kindly let me know how to patch hardware raid implemented Servers. Thanks... Rj (7 Replies)
Discussion started by: jegaraman
7 Replies

9. Solaris

Hardware RAID using three disks

Dear All , Pl find the below command , # raidctl -l Controller: 1 Volume:c1t0d0 Disk: 0.0.0 Disk: 0.1.0 Disk: 0.3.0 # raidctl -l c1t0d0 Volume Size Stripe Status Cache RAID Sub Size ... (10 Replies)
Discussion started by: jegaraman
10 Replies
vximportdg(1M)															    vximportdg(1M)

NAME
vximportdg - import a disk group into the Veritas Volume Manager configuration SYNOPSIS
vximportdg daname new_dgname DESCRIPTION
The vximportdg utility performs a temporary import of the disk group contained on the disk device specified by daname to the disk group specified by new_dgname. As the persistent disk group information is not changed within the private partition of the affected disk, the import is only valid for the duration of the bootload or until a vxdg deport is performed. ARGUMENTS
daname Specifies the device name (disk access name) of one of the member disks of the disk group to be imported. The other members are imported automatically. new_dgname Specifies the disk group to be imported. USAGE
One reason to use the vximportdg utility is to import a second generation of the rootdg disk group so that its objects are available for use while a system is running on a different rootdg. To prevent volumes on the second generation rootdg from having the same device minor numbers as volumes (such as rootvol) on the active rootdg, the importation assigns temporary non-conflicting device minor numbers. If this occurs, vximportdg outputs warning messages detailing the mapping of the minor numbers. SEE ALSO
vxdg(1M) VxVM 5.0.31.1 24 Mar 2008 vximportdg(1M)
All times are GMT -4. The time now is 09:28 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy