Sponsored Content
Full Discussion: Linux on SAN
Operating Systems Linux Linux on SAN Post 302200061 by goon12 on Wednesday 28th of May 2008 09:53:14 AM
Old 05-28-2008
You could try this:

Code:
echo "- - -" > /sys/class/scsi_host/host<X>/scan

<X> is the host number.
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

what is SAN

Hello all, I have looked at the entire posting that have SAN in it and I'm still fuzzy on how SAN works. I understand that every disk array can be access from any server that needs it, but is there software that is install or NFS mount type situation. One post stated that if your format command... (7 Replies)
Discussion started by: larry
7 Replies

2. AIX

San:

hi We have 2 AIX nodes running with HACMP and all of them connected to SAN, Our shared storage is shark; I need to create shared volume group and I need the HACMP take a ware of it. Regards (1 Reply)
Discussion started by: h2aix
1 Replies

3. Solaris

Thoughts/experiences of SAN attaching V880 to EMC SAN

Hi everyone, I wonder if I can canvas any opinions or thoughts (good or bad) on SAN attaching a SUN V880/490 to an EMC Clarion SAN? At the moment the 880 is using 12 internal FC-AL disks as a db server and seems to be doing a pretty good job. It is not I/O, CPU or Memory constrained and the... (2 Replies)
Discussion started by: si_linux
2 Replies

4. Filesystems, Disks and Memory

Multiple Paths to SAN with LVM in Linux?

I'm setting up a CentOS 5 server that will be connected to an HP EVA4000. My previous experience is with an HP VA7400 and HP-UX. In HP-UX I can add "alternate paths" to a volume group in order to have redundant paths to the SAN via dual fiber channel HBAs just by either adding them with... (3 Replies)
Discussion started by: deckard
3 Replies

5. Filesystems, Disks and Memory

Finding SAN Lun's on Linux.

Am trying to differentiate between the local disks and LUN's presented from SAN onto the server. Have Tried fdisk -l, however I quite cudn't differentiate the local disks from SAN presented LUN's. Can you pls. let me know the procedure and commands to find this. OS - RHEL 4 SAN - EMC... (3 Replies)
Discussion started by: Crazy_murli
3 Replies

6. Filesystems, Disks and Memory

how to create same paritations from same SAN disk on two linux servers

Hi All, Storage team assigned same SAN disk on two servers how to create same paritations from same SAN disk on two linux servers may i know options & procedure. But here one server writing on SAN disk and another server reading other files from SAN disks Thanks in advance (1 Reply)
Discussion started by: kurva
1 Replies

7. AIX

IBM SAN TO SAN Mirroring

Has anyone tried SAN to SAN mirroring on IBM DS SAN Storage. DS5020 mentions Enhanced Remote Mirror to multi-LUN applications I wonder if Oracle High availibility can be setup using Remote Mirror option of SAN ? (1 Reply)
Discussion started by: filosophizer
1 Replies

8. Linux

How to Find out if an HP/Linux uses SAN or not?

Is there a command I can run on my HP /LINUX to see if uses SAN? This command work son AIX ls -al /DEV/rdsk however it does not work on HP Linux. Please let me know? Thanks (4 Replies)
Discussion started by: mrn6430
4 Replies

9. AIX

SAN Migration

Hi all, We are migrating our SAN storage from HSV360 to 3PAR. The system runs aix 6.1 version with HACMP. Please let me know what are requirements from OS side and how are the data copied to the new disks. (10 Replies)
Discussion started by: ElizabethPJ
10 Replies

10. Filesystems, Disks and Memory

Faster way: SAN hd to SAN hd copying

hi! i got a rhel 6.3 host that already have an xfs filesystem mounted from a SAN (let's call it SAN-1) whose size is 9TB. i will be receiving another SAN (let's call it SAN-2) storage of 15TB size. this new addition is physically on another SAN storage. SAN-1 is on a Pillar storage while the new... (6 Replies)
Discussion started by: rino19ny
6 Replies
HPSA(4) 						     Linux Programmer's Manual							   HPSA(4)

NAME
hpsa - HP Smart Array SCSI driver SYNOPSIS
modprobe hpsa [ hpsa_allow_any=1 ] DESCRIPTION
hpsa is a SCSI driver for HP Smart Array RAID controllers. Options hpsa_allow_any=1: This option allows the driver to attempt to operate on any HP Smart Array hardware RAID controller, even if it is not explicitly known to the driver. This allows newer hardware to work with older drivers. Typically this is used to allow installation of operating systems from media that predates the RAID controller, though it may also be used to enable hpsa to drive older controllers that would normally be handled by the cciss(4) driver. These older boards have not been tested and are not supported with hpsa, and cciss(4) should still be used for these. Supported hardware The hpsa driver supports the following Smart Array boards: Smart Array P700M Smart Array P212 Smart Array P410 Smart Array P410i Smart Array P411 Smart Array P812 Smart Array P712m Smart Array P711m StorageWorks P1210m Since Linux 4.14, the following Smart Array boards are also supported: Smart Array 5300 Smart Array 5312 Smart Array 532 Smart Array 5i Smart Array 6400 Smart Array 6400 EM Smart Array 641 Smart Array 642 Smart Array 6i Smart Array E200 Smart Array E200i Smart Array E200i Smart Array E200i Smart Array E200i Smart Array E500 Smart Array P400 Smart Array P400i Smart Array P600 Smart Array P700m Smart Array P800 Configuration details To configure HP Smart Array controllers, use the HP Array Configuration Utility (either hpacuxe(8) or hpacucli(8)) or the Offline ROM-based Configuration Utility (ORCA) run from the Smart Array's option ROM at boot time. FILES
Device nodes Logical drives are accessed via the SCSI disk driver (sd(4)), tape drives via the SCSI tape driver (st(4)), and the RAID controller via the SCSI generic driver (sg(4)), with device nodes named /dev/sd*, /dev/st*, and /dev/sg*, respectively. HPSA-specific host attribute files in /sys /sys/class/scsi_host/host*/rescan This is a write-only attribute. Writing to this attribute will cause the driver to scan for new, changed, or removed devices (e.g., hot-plugged tape drives, or newly configured or deleted logical drives, etc.) and notify the SCSI midlayer of any changes detected. Normally a rescan is triggered automatically by HP's Array Configuration Utility (either the GUI or the command-line variety); thus, for logical drive changes, the user should not normally have to use this attribute. This attribute may be useful when hot plugging devices like tape drives, or entire storage boxes containing preconfigured logical drives. /sys/class/scsi_host/host*/firmware_revision This attribute contains the firmware version of the Smart Array. For example: # cd /sys/class/scsi_host/host4 # cat firmware_revision 7.14 HPSA-specific disk attribute files in /sys /sys/class/scsi_disk/c:b:t:l/device/unique_id This attribute contains a 32 hex-digit unique ID for each logical drive. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat unique_id 600508B1001044395355323037570F77 /sys/class/scsi_disk/c:b:t:l/device/raid_level This attribute contains the RAID level of each logical drive. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat raid_level RAID 0 /sys/class/scsi_disk/c:b:t:l/device/lunid This attribute contains the 16 hex-digit (8 byte) LUN ID by which a logical drive or physical device can be addressed. c:b:t:l are the controller, bus, target, and lun of the device. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat lunid 0x0000004000000000 Supported ioctl() operations For compatibility with applications written for the cciss(4) driver, many, but not all of the ioctls supported by the cciss(4) driver are also supported by the hpsa driver. The data structures used by these ioctls are described in the Linux kernel source file include/linux/cciss_ioctl.h. CCISS_DEREGDISK, CCISS_REGNEWDISK, CCISS_REGNEWD These three ioctls all do exactly the same thing, which is to cause the driver to rescan for new devices. This does exactly the same thing as writing to the hpsa-specific host "rescan" attribute. CCISS_GETPCIINFO Returns PCI domain, bus, device and function and "board ID" (PCI subsystem ID). CCISS_GETDRIVVER Returns driver version in three bytes encoded as: (major_version << 16) | (minor_version << 8) | (subminor_version) CCISS_PASSTHRU, CCISS_BIG_PASSTHRU Allows "BMIC" and "CISS" commands to be passed through to the Smart Array. These are used extensively by the HP Array Configuration Utility, SNMP storage agents, and so on. See cciss_vol_status at <http://cciss.sf.net> for some examples. SEE ALSO
cciss(4), sd(4), st(4), cciss_vol_status(8), hpacucli(8), hpacuxe(8), <http://cciss.sf.net>, and Documentation/scsi/hpsa.txt and Documentation/ABI/testing/sysfs-bus-pci-devices-cciss in the Linux kernel source tree COLOPHON
This page is part of release 4.15 of the Linux man-pages project. A description of the project, information about reporting bugs, and the latest version of this page, can be found at https://www.kernel.org/doc/man-pages/. Linux 2017-09-15 HPSA(4)
All times are GMT -4. The time now is 09:06 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.