Old 05-26-2008
It would kind've assist people who are trying to help you if you at least gave soem detail on what Veritas product you are referring to?

Volume Manager
File System
Cluster Server
???
 

10 More Discussions You Might Find Interesting

1. Solaris

NIC cards for sunblade 100

I need to add a PCI NIC to a sunblade 100 running solaris 8. Im new to this and was hoping someone could give me some card names and models which will work for this system and has a driver for this sparc system. thanks (3 Replies)
Discussion started by: meyersp
3 Replies

2. IP Networking

Setup 2 NIC cards in one UNIX system

Hi; I have a UNIX box (SCO 5.0.2) with two (2) NIC cards. One card (NIC1) talks to a network 57.14.65.x/27. The other card NIC2) talks to users on 57.14.103.x and 57.14.105.x with subnet mask of 255.255.0.0. If I set NIC2 to this subnet mask (255.255.0.0) it seems like the NIC traffic is now... (2 Replies)
Discussion started by: texaspanama
2 Replies

3. HP-UX

routing issues with multiple NIC cards

I am running HP_UX 11.23 with 4 NIC cards (this is our TSM server) I have 4 subnets we are backing across. trying to keep traffic on their subnets. I only have one route statment should I add more. route add net 123.99.8.0 netmask 255.255.255.0 123.99.8.254 route add net 123.99.67.0 netmask... (2 Replies)
Discussion started by: myork
2 Replies

4. Red Hat

External NIC cards not pinging with each other in RHEL 5.1

We have a setup of two nodes which has two NIC cards in each. One is built in and another is D-Link (external NIC card). We are unable to ping to the external NIC cards in both. Eg: Node A has two IPs 192.168.1.10 (eth0) and 192.168.2.10 (eth1) and Node B has two IPs 192.168.1.20 (eth0) and... (3 Replies)
Discussion started by: durgaprasadr13
3 Replies

5. HP-UX

HP UX 9000 NIC CARDS

Hello, I am trying to move an HP UX from one locaion to another. The new location don't have any Fiber switches. On the back of my server I see 2 RJ 45 for console management the other for networking , the server also has a fiber NIC card. When I disconnec the fiber and want to user regular... (1 Reply)
Discussion started by: ldaliosmane
1 Replies

6. IP Networking

Best reference for understanding low level info on nic cards drivers and functionality

Hi, What is the best reference that gives in detail on nic cards configuration , assigning multiple ip addresses to a single interface, netlink library etc and all basic stuff at this level..? Thanks (2 Replies)
Discussion started by: Gopi Krishna P
2 Replies

7. Ubuntu

Help asap squid with 2 nic cards setup

I found an old post that talks about 2 nice cards and it is driven by the IP address .... but I didn't understand it because the 2 people skipped information for me the newbie.. Can someone help me... I have the proxy server setup and I believe I have enabled the 2nd nic card, I just need one... (1 Reply)
Discussion started by: trilju2005
1 Replies

8. Ubuntu

How do you setup 2 nic cards for squid Ubuntu server?

I have a made my squid proxy, I now have add another nic card to an old CPU using Ubuntu server 12.04. I have seen another post similar however I am new and did not understand some of it. Something about redirecting IP address and IP table? I don't know how to do this.:confused: (9 Replies)
Discussion started by: trilju2005
9 Replies

9. Linux

Add two different subnet public IPs to single NIC or two different NIC on same box

Hello Admins, My ask is how can I add two different subnet IPs to same box with two different gateways? The issue is I can connect to the box when I am on ethernet LAN, but I am not able to connect to the same IP when I am on wifi. The server is RHEL 7 VM on vmware. How can I get connected... (4 Replies)
Discussion started by: snchaudhari2
4 Replies

10. UNIX for Beginners Questions & Answers

How to extend a disk in veritas volume manager in veritas cluster?

Hi Experts, I wanted to extend a veritas file system which is running on veritas cluster and mounted on node2 system. #hastatus -sum -- System State Frozen A node1 running 0 A node2 running 0 -- Group State -- Group System Probed ... (1 Reply)
Discussion started by: Skmanojkum
1 Replies
vxiod(1M)																 vxiod(1M)

NAME
vxiod - start, stop, and report on Veritas Volume Manager I/O threads SYNOPSIS
vxiod vxiod [-f ] [set count] DESCRIPTION
The vxiod utility starts, stops, or reports on Veritas Volume Manager (VxVM) I/O kernel threads. An I/O thread provides a process context for performing I/O in VxVM. When the vxio module is loaded, 16 I/O threads are created, plus 2 threads per additional CPU for a system with more than 8 CPUs, up to a maximum of 64 threads. At least one I/O thread must be running while the vxio module is loaded, and the number of I/O threads cannot be forced to zero. When invoked with no arguments, vxiod prints the current number of I/O threads to the standard output. The number of threads that is required for handling I/O requests depends on the system load and usage. If volume recovery seems to proceed more slowly at times, it may be possible to improve its performance by increasing the number of I/O threads up to a maximum of 64. KEYWORDS
set When invoked with the set keyword, vxiod creates the number of I/O threads specified by count. If more volume I/O threads exist than are specified by count, the excess processes terminate. If more than the maximum number(64) are specified, the requested number is silently truncated to that maximum. OPTIONS
-f This option has no effect from release 5.0 onward. The number of I/O threads cannot be reduced to zero. EXIT CODES
The vxiod utility prints a diagnostic on the standard error, and exits if an error is encountered. If an I/O request occurs within a I/O thread, the state of that I/O request is not reflected in the exit status for vxiod. Otherwise, vxiod returns a non-zero exit status on error. Usage errors result in an exit status of 1 and a usage message. If the requested number of threads cannot be created, the exit status is 2, and the number of threads that were successfully started is reported. If any other error occurs, the exit status is 3. FILES
/dev/vx/iod The device used to report on and start volume I/O threads. NOTES
Veritas Volume Manager I/O threads cannot be killed directly through the use of signals. Depending on the operating system, VxVM I/O threads may not appear in the list of processes that is output by the ps command. The number of I/O threads that is currently running can be determined by running vxiod. SEE ALSO
fork(2), ps(1), vxconfigd(1M), vxdctl(1M), vxintro(1M), vxio(7), vxiod(7) VxVM 5.0.31.1 24 Mar 2008 vxiod(1M)
All times are GMT -4. The time now is 09:14 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy