I ran luxadm -e port and noticed that the disks that are having the error shows not connected:
# luxadm -e port
/devices/pci@1c,600000/SUNW,qlc@1/fp@0,0:devctl CONNECTED
/devices/pci@1c,600000/SUNW,qlc@1,1/fp@0,0:devctl NOT CONNECTED
/devices/pci@1d,700000/SUNW,qlc@2,1/fp@0,0:devctl NOT CONNECTED
/devices/pci@1d,700000/SUNW,qlc@2/fp@0,0:devctl CONNECTED
How do I connect these disks?
Check your fibre connection with:
If a controller is not seen, or seen as unconfigured run:
Hi
I have a linux box attched to a SAN storage from EMC with RAID 5 .I understand that it has 3g cache howver a 20gb file creation takes too much time here are my results any ideas why
time dd if=/dev/zero of=disk.img bs=1048576 count=20000
20000+0 records in
20000+0 records out
997.59s... (2 Replies)
I have my application vendor looking at this but I want to do my own investigation.
I restored from mksysb and I see my vgs that contain my internal disks.
But I do not see my vgs that contain disks from the SAN. This scares me ..
{{ Ha, ha!! My AIX expert boss just told me I have nothing... (0 Replies)
This may sound like an absolute rookie question, and it is.
I have been working on Migrating our HP and Solaris servers to the new EMC SAN and know the routines backwards.
Now we've suddenly got a new IBM server and I don't even know how to check if it is connected to the switch.
Can someone... (1 Reply)
Good morning to one and all :-) Thank god its Friday, as its bee na rubbish week for me !
So, a quick question. Disks ! Ive got a few local disks, and a few SAN disks used on my solaris server. Whats confusing me, and Im not sure if there's an issue at the SAN end, or my end, regarding the... (3 Replies)
Hi,
I'm new to SAN storage so I was wondering if someone can assist me with a problem. I have a solaris 10 OS with 3 SAN devices attached. We are trying to troubleshoot performance so I was asked to get the WWN of each SAN disk and show what it's attached to via the SVM mount in the metastat... (1 Reply)
Hello everybody,
I'm using the binary inqraid (Linux RHEL) in order to retrieve information about SAN disks. The questions are:
Given an LDEV, how do I know if the SAN disk related to this LDEV is being used by the OS? I mean, how can I demonstrate to "Storage department" that all disks of... (4 Replies)
HI, I have had an issue last night while trying to extend a filesystsem . chvg -g <vg> command cameback with an error
0516-1790 chvg: Failed bootinfo -s hdisk9.
Ensure the physical volume is available and try again.
0516-732 chvg: Unable to change volume group u01vg.
the VG has 1... (1 Reply)
Hello, I'm trying to get to the bottom of SAN disk errors we've been seeing.
Server is Sun Fire X4270 M2 running Solaris 10 8/11 u10 X86 since April 2012. SAN HBAs are SG-PCIE2FC-QF8-Z-Sun-branded Qlogic. SAN storage system is Hitachi VSP. We have 32 LUNs in use and another 8 LUNs not brought... (4 Replies)
Discussion started by: TKD
4 Replies
LEARN ABOUT SUNOS
fp
fp(7d) Devices fp(7d)NAME
fp - Sun Fibre Channel port driver
DESCRIPTION
The fp driver is a Sun fibre channel nexus driver that enables fibre channel topology discovery, device discovery, fibre channel adapter
port management and other capabilities through well-defined fibre channel adapter driver interfaces.
The fp driver requires the presence of a fabric name server in fabric and public loop topologies to discover fibre channel devices. In pri-
vate loop topologies, the driver discovers devices by performing PLOGI to all valid AL_PAs, provided that devices do not participate in
LIRP and LILP stages of loop initialization.
CONFIGURATION
The fp driver is configured by defining properties in the fp.conf file. The fp driver supports the following properties:
mpxio-disable
Solaris I/O multipathing is enabled or disabled on fibre channel devices with the mpxio-disable property. Specifying mpxio-disable="no"
activates I/O multipathing, while mpxio-disable="yes" disables the feature.
Solaris I/O multipathing may be enabled or disabled on a per port basis. Per port settings override the global setting for the specified
ports. The following example shows how to disable multipathing on port 0 whose parent is /pci@8,600000/SUNW,qlc@4:
name="fp" parent="/pci@8,600000/SUNW,qlc@4" port=0
mpxio-disable="yes";
manual_configuration_only
Automatic configuration of SCSI devices in the fabric is enabled by default and thus allows all devices discovered in the SAN zone to be
enumerated in the kernel's device tree automatically. The manual_configuration_only property may be configured to disable the default
behavior and force the manual configuration of the devices in the SAN. Specifying manual_configuration_only=1 disables the automatic con-
figuration of devices.
FILES
/kernel/drv/fp
32-bit ELF kernel driver (x86)
/kernel/drv/amd64/fp
64-bit ELF kernel driver (x86)
/kernel/drv/sparcv9/fp
64-bit ELF kernel driver (SPARC)
/kernel/drv/fp.conf
fp driver configuration file.
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|mpxio-disable |Unstable |
+-----------------------------+-----------------------------+
|manual_configuration_only |Obsolete |
+-----------------------------+-----------------------------+
|Availability |SUNWfctl |
+-----------------------------+-----------------------------+
SEE ALSO cfgadm_fp(1M), prtconf(1M), stmsboot(1M), driver.conf(4), attributes(5), fcp(7D), fctl(7D), scsi_vhci(7D)
Writing Device Drivers
Fibre Channel Physical and Signaling Interface (FC-PH) ANSI X3.230: 1994
Fibre Channel Generic Services (FC-GS-2) Project 1134-D
Fibre Channel Arbitrated Loop (FC-AL) ANSI X3.272-1996
Fibre Channel Protocol for SCSI (FCP) ANSI X3.269-1996
SCSI-3 Architecture Model (SAM) Fibre Channel Private Loop SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996
SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996
SCSI Direct Attach (FC-PLDA) NCITS TR-19:1998
Fabric Loop Attachment (FC-FLA), NCITS TR-20:1998
SunOS 5.10 2 Dec 2004 fp(7d)