Operating Systems Solaris Disk Replacement SVM Post 302197391 by hercu on Wednesday 21st of May 2008 01:14:15 AM
Old 05-21-2008
I have sued both! The trick is to use 'metareplace' in case the entire disk goes bad!! That is faster and works okay

If only some slices are bad, then you need to follow the 'tedious' procedure that you mentioned in the very first post.

Extra:
Concerning usuing the cfgadm command, I have seen most sun engineers not using them while many sys admins use that - may be for security / satisfaction sake. Remember, cfgadm will eb used if you have scsi disks on your machine. ** 'luxadm' command is used instead of cfgadm incase your machine has fiber channel disks. (To find out if your system has FCAL disks, run format command and see if there is a long series of numbers after t (target) of the disks).

Hope that helps Smilie
 

10 More Discussions You Might Find Interesting

1. Solaris

Disk replacement with svm

I dont even know what raid level this is, but its raid 5 mirrored from the looks of it. I have a failed disk (t12) within this mirror. What is the best way to replace this disk? 2 things concern me, isn't there a command to prepare the disk for a hot swap? and what should i do with the... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies

2. Solaris

Removing Disk from SVM

Hi All, I have to remove the disk from SVM. Kindly guide me or suggest me some link where in I can steps to remove SVM from Solaris 10 .Also I have one metaset which require deletion. Thanks in anticipation! (10 Replies)
Discussion started by: kumarmani
10 Replies

3. Solaris

Disk space missing under SVM

Hi Gurus, I've got an issue here: (1) Hardware: Sun NetraT1, (2) OS: Solaris 10, (3) SVM metastat shows /var having 12 GB. df shows /var having 4 GB. Real space for /var is about 4 GB since I can't move a big file to it. How is 8 GB space missing? Does /var/run swap need to account? Can I... (5 Replies)
Discussion started by: aixlover
5 Replies

4. Solaris

Root Disk mirroring in SVM

Dear All, Please help me to configure root mirroring using SVM in Solaris 9. Thanks and Regards, Lakkireddy BR (3 Replies)
Discussion started by: lbreddy
3 Replies

5. Solaris

Replacing a hard disk (SVM) with a soft partition?

The following is the summarry:- 1) Four disks in server ie (c1t0d0. c1t1d0, c1t2d0, c1t3d0). c1t2d0 is the disk to be replaced. c1t0d0 and c1t2d0 are mirrors. c1t1d0 and c1t3d0 are mirrors. Metadb to be deleted is in c1t2d0s7 a) Mirror d35 has 2 submirrors d38 and d39 d38 is a stripe... (0 Replies)
Discussion started by: aji1729
0 Replies

6. Solaris

Root disk mirroring in SVM

I tried doing rootdisk mirroring in my local host , i added a new Ide disk in my system and copied the prtvtoc from root disk to the newly added disk, and then when i tried to add database replicas on both the disks, it was added for boot disk but for the newly added disk i gave the error, which... (6 Replies)
Discussion started by: Laxxi
6 Replies

7. Solaris

Replacing a Disk in a ODS/SVM Mirror

Hi All BAsed on the below I would like to verifu two things (1) The udnerlying mirroris for '/mnt' na dit onlcy contaisne 1 sub-mirror, with one sliceon is one disk and hence, data loss on the mount point (the mount point, '/mnt' is backed up) (2) the Procedure for renewal # df -kh /mnt... (2 Replies)
Discussion started by: stevie_velvet
2 Replies

8. Solaris

Replacing a failed disk using SVM

Hi Please can you help me on replacing or removing a faulty disk drive on a SUN NETRA X4250server with 4 internal drives only. the format comand show me the following: format Searching for disks...done AVAILABLE DISK SELECTIONS: 0. c0t0d0 <drive type unknown> ... (9 Replies)
Discussion started by: fretagi
9 Replies

9. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

10. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies
vxsparecheck(1M)														  vxsparecheck(1M)

NAME
vxsparecheck - monitor Veritas Volume Manager for failure events and replace failed disks SYNOPSIS
/etc/vx/bin/vxsparecheck [mail-address...] DESCRIPTION
The vxsparecheck command monitors Veritas Volume Manager (VxVM) by analyzing the output of the vxnotify command, waiting for failures to occur. It then sends mail via mailx to the logins specified on the command line, or (by default) to root. It then replaces any failed disks. After an attempt at replacement is complete, mail will be sent indicating the status of each disk replacement. The mail notification that is sent when a failure is detected follows this format: Failures have been detected by the Veritas Volume Manager: failed disks: medianame ... failed plexes: plexname ... failed subdisks: subdiskname ... failed volumes: volumename ... The Volume Manager will attempt to find hot-spare disks to replace any failed disks and attempt to reconstruct any data in volumes that have storage on the failed disk. The medianame list specifies disks that appear to have completely failed. The plexname list show plexes of mirrored volumes that have been detached due to I/O failures experienced while attempting to do I/O to subdisks they contain. The subdiskname list specifies subdisks in RAID-5 volumes that have been detached due to I/O errors. The volumename list shows non-RAID-5 volumes that have become unusable because disks in all of their plexes have failed (and are listed in the ``failed disks'' list) and shows those RAID-5 volumes that have become unusable because of multiple failures. If any volumes appear to have failed, the following paragraph will be included in the mail: The data in the failed volumes listed above is no longer available. It will need to be restored from backup. Replacement Procedure After mail has been sent, vxsparecheck finds a hot spare replacement for any disks that appear to have failed (that is, those listed in the medianame list). This involves finding an appropriate replacement for those eligible hot spares in the same disk group as the failed disk. A disk is eligible as a replacement if it is a valid Veritas Volume Manager disk (VM disk), has been marked as a hot-spare disk and con- tains enough space to hold the data contained in all the subdisks on the failed disk. To determine which disk from among the eligible hot spares to use, vxsparecheck first checks the file /etc/vx/sparelist (see Sparelist File below). If this file does not exist or lists no eligible hot spares for the failed disk, the disk that is ``closest'' to the failed disk is chosen. The value of ``closeness'' depends on the controller, target and disk number of the failed disk. A disk on the same controller as the failed disk is closer than a disk on a different controller; and a disk under the same target as the failed disk is closer than one under a different target. If no hot spare disk can be found, the following mail is sent: No hot spare could be found for disk medianame in diskgroup. No replacement has been made and the disk is still unusable. The mail then explains the disposition of volumes that had storage on the failed disk. The following message lists disks that had storage on the failed disk, but are still usable: The following volumes have storage on medianame: volumename These volumes are still usable, but the redundancy of those volumes is reduced. Any RAID-5 volumes with storage on the failed disk may become unusable in the face of further failures. If any non-RAID-5 volumes were made unusable due to the failure of the disk, the following message is included: The following volumes: volumename have data on medianame but have no other usable mirrors on other disks. These volumes are now unusable and the data on them is unavailable. If any RAID-5 volumes were made unavailable due to the disk failure, the following message is included The following RAID-5 volumes: volumename had storage on medianame and have experienced other failures. These RAID-5 volumes are now unusable and data on them is unavailable. If a hot-spare disk was found, a hot-spare replacement is attempted. This involves associating the device marked as a hot spare with the media record that was associated with the failed disk. If this is successful, the vxrecover(1M) command is used in the background to recover the contents of any data in volumes that had storage on the disk. If the hot-spare replacement fails, the following message is sent: Replacement of disk medianame in group diskgroup failed. The error is: error message If any volumes (RAID-5 or otherwise) are rendered unusable due to the failure, the following message is included: The following volumes: volumename occupy space on the failed disk and have no other available mirrors or have experienced other failures. These volumes are unusable, and the data they contain is unavailable. If the hot-spare replacement procedure completed successfully and recovery is under way, a final mail message is sent: Replacement of disk medianame in group diskgroup with disk device sparedevice has successfully completed and recovery is under way. If any non-RAID-5 volumes were rendered unusable by the failure despite the successful hot-spare procedure, the following message is included in the mail: The following volumes: volumename occupy spare on the replaced disk, but have no other enabled mirrors on other disks from which to perform recovery. These volumes must have their data restored. If any RAID-5 volumes were rendered unusable by the failure despite the successful hot-spare procedure, the following message is included in the mail: The following RAID-5 volumes: volumename have subdisks on the replaced disk and have experienced other failures that prevent recovery. These RAID-5 volumes must have their data restored. If any volumes (RAID-5 or otherwise) were rendered unusable, the following message is also included: To restore the contents of any volumes listed above, the volume should be started with the command: vxvol -f start volumename and the data restored from backup. Sparelist File The sparelist file is a text file that specifies an ordered list of disks to be used as hot spares when a specific disk fails. The system- wide sparelist file is located in /etc/vx/sparelist. Each line in the sparelist file specifies a list of spares for one disk. Lines beginning with the pound (#) character and empty lines are ignored. The format for a line in the sparelist file is: [ diskgroup:] diskname : spare1 [ spare2 ... ] The diskgroup field, if present, specifies the disk group within which the disk and designated spares reside. If this field is not speci- fied, the default disk group is determined using the rules given in the vxdg(1M) manual page. The diskname specifies the disk for which spares are being designated. The spare list after the colon lists the disks to be used as hot spares. The list is order dependent; in case of failure of diskname, the spares are tried in order. A spare will be used only if it is a valid hot spare (see above). If the list is exhausted without finding any spares, the default policy of using the closest disk is used. FILES
/etc/vx/sparelist Specifies a list of disks to serve as hot spares for a disk. NOTES
The sparelist file is not checked in any way for correctness until a disk failure occurs. It is possible to inadvertently specify a non- existent disk or inappropriate disk or disk group. Malformed lines are also ignored. SEE ALSO
mailx(1), vxintro(1M), vxnotify(1M), vxrecover(1M), vxrelocd(1M), vxunreloc(1M) VxVM 5.0.31.1 24 Mar 2008 vxsparecheck(1M)