05-20-2008
aha. Thanks for the detailed question.
Dual path for the two 2540's via two HBA's
(SG-XPCIE2FC-QF4)
Single path for the one 6140 via one HBA
(SG-XPCIE2FC-QF4)
btw, I haven't had much luck asking these questions to several sun var's and sales engineers
If anyone has the best bang/buck config. please share.
Thanks again.
-bv
8 More Discussions You Might Find Interesting
1. Solaris
I have a Sun Sparc T2000 (Solaris 10 05-08) and have installed a PCI-X 4GB Single Port HBA card in it.
I have one StorageTek 2540 array that I would like to connect to the T2000.
For the moment it would be a single path connection, but I've ordered a 2nd HBA, so eventually it would be... (4 Replies)
Discussion started by: soliberus
4 Replies
2. Filesystems, Disks and Memory
Hi,
We have 12x1TB SATA disks in our array and I need to create 10TB volume. I defined new storage profile on array and when I tried to add volume, I faced with ~2TB limit for new volumes. I didn't find how to set another limit on my storage profile. Is there is a way to configure one large... (3 Replies)
Discussion started by: Sapfeer
3 Replies
3. Solaris
Hi,
I have a simple question on how to correctly disable the matrix?
Looking for the Common Array Manager and I do not see this option...
Thank for help (3 Replies)
Discussion started by: bieszczaders
3 Replies
4. Solaris
Hi peeps,
Was wondering if anyone can help me, got a couple of storagetek 2540's that I need to configure. Trouble is I think they were brought as second user as all that came with them was cables.
Does anyone know how to configure them (i.e. create raid sets and map to Luns and present... (1 Reply)
Discussion started by: callmebob
1 Replies
5. Hardware
Hello all !
I am a beginner about system and networking , and after some research on internet , i didn't find any relevant information , so i post here , if someone have an experience with this kind of material or if some documentation about how to connect my storage device on my server.
I... (2 Replies)
Discussion started by: acorradi
2 Replies
6. Hardware
Hi all,
My Sun StorageTek 2540 have redundant batteries, but a battery was failed.
# /opt/SUNWstkcam/bin/sscs list -d MyStorage1 fru
Name FRU Alarm State Status Revision Unique Id
-------------------------- ----------- --------... (2 Replies)
Discussion started by: buyantugs
2 Replies
7. Hardware
Hi Guys and Gals,
Wionder if you could help me, got a problem with a controller on a storagetek 2540, dead when fully powered up but if you reboot, it is ok for a couple of seconds (and you can ping it). Then once the array is fully up, it goes faulty and is un-pingable.
Had anyone... (4 Replies)
Discussion started by: callmebob
4 Replies
8. Solaris
Bought a Sun StorageTek 2540 SAN array a few years ago from a company that was going out of business. When we first set it up, we were able to get all the software (Common Array Manager) and firmware directly from Sun.
We just upgraded the drives, but the array is too large for the firmware. Now... (6 Replies)
Discussion started by: edison303
6 Replies
LEARN ABOUT OPENSOLARIS
hba_refreshinformation
HBA_RefreshInformation(3HBAAPI) Common Fibre Channel HBA Information Library Functions HBA_RefreshInformation(3HBAAPI)
NAME
HBA_RefreshInformation, HBA_RefreshAdapterConfiguration - refresh information for a specific HBA
SYNOPSIS
cc [ flag... ] file... -lHBAAPI [ library... ]
#include <hbaapi.h>
void HBA_RefreshInformation(HBA_HANDLE handle);
void HBA_RefreshAdapterConfiguration(void);
PARAMETERS
handle an open handle returned from HBA_OpenAdapter(3HBAAPI)
DESCRIPTION
The HBA_RefreshInformation() function requests that the underlying VSL reload all information about the given HBA. This function should be
called whenever any function returns HBA_STATUS_ERROR_STALE_DATA, or if an index that was previously valid returns HBA_STATUS_ERROR_ILLE-
GAL_INDEX. Because the underlying VSL can reset all indexes relating to the HBA, all old index values must be discarded by the caller.
The HBA_RefreshAdapterConfiguration() function updates information about the HBAs present on the system. This function does not change any
of the relationships between the HBA API and adapters that have not been reconfigured. HBA handles continue to refer to the same HBA even
if it is no longer installed. The HBA name or index assigned by the library remains assigned to the same HBA even if it has been removed
and reinstalled, as long as the bus position, WWN, and OS device have not changed. Adapter that have been removed and not replaced cannot
have their HBA handles, HBA names, and HBA indexes reassigned. Calls to these adapters will generate HBA_STATUS_ERROR_UNAVAILABLE.
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-------------------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-------------------------------------+
|Interface Stability |Standard: FC-MI 1.92 (API version 1) |
+-----------------------------+-------------------------------------+
| |Standard: FC-HBA Version 4 (API ver- |
| |sion 2) |
+-----------------------------+-------------------------------------+
|MT-Level |Safe |
+-----------------------------+-------------------------------------+
SEE ALSO
HBA_OpenAdapter(3HBAAPI), libhbaapi(3LIB), attributes(5)
T11 FC-MI Specification