05-17-2008
Thanks for the reply, however when I keep getting errors from metadevadm relating to invalid device information on the replaced disk. This has led me to believe that I need to configure the new disk to get a new DevID generated.
10 More Discussions You Might Find Interesting
1. Solaris
I dont even know what raid level this is, but its raid 5 mirrored from the looks of it.
I have a failed disk (t12) within this mirror. What is the best way to replace this disk? 2 things concern me, isn't there a command to prepare the disk for a hot swap? and what should i do with the... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies
2. Solaris
Hi All,
I have to remove the disk from SVM.
Kindly guide me or suggest me some link where in I can steps to remove SVM from Solaris 10 .Also I have one metaset which require deletion.
Thanks in anticipation! (10 Replies)
Discussion started by: kumarmani
10 Replies
3. Solaris
Hi Gurus, I've got an issue here:
(1) Hardware: Sun NetraT1, (2) OS: Solaris 10, (3) SVM
metastat shows /var having 12 GB. df shows /var having 4 GB. Real space for /var is about 4 GB since I can't move a big file to it. How is 8 GB space missing? Does /var/run swap need to account? Can I... (5 Replies)
Discussion started by: aixlover
5 Replies
4. Solaris
Dear All,
Please help me to configure root mirroring using SVM in Solaris 9.
Thanks and Regards,
Lakkireddy BR (3 Replies)
Discussion started by: lbreddy
3 Replies
5. Solaris
The following is the summarry:-
1) Four disks in server ie (c1t0d0. c1t1d0, c1t2d0, c1t3d0). c1t2d0 is the disk to be replaced.
c1t0d0 and c1t2d0 are mirrors.
c1t1d0 and c1t3d0 are mirrors.
Metadb to be deleted is in c1t2d0s7
a) Mirror d35 has 2 submirrors d38 and d39
d38 is a stripe... (0 Replies)
Discussion started by: aji1729
0 Replies
6. Solaris
I tried doing rootdisk mirroring in my local host , i added a new Ide disk in my system
and copied the prtvtoc from root disk to the newly added disk, and then when i tried to add database replicas on both the disks, it was added for boot disk but for the newly added disk i gave the error, which... (6 Replies)
Discussion started by: Laxxi
6 Replies
7. Solaris
Hi All
BAsed on the below I would like to verifu two things
(1) The udnerlying mirroris for '/mnt' na dit onlcy contaisne 1 sub-mirror, with one sliceon is one disk and hence, data loss on the mount point (the mount point, '/mnt' is backed up)
(2) the Procedure for renewal
# df -kh /mnt... (2 Replies)
Discussion started by: stevie_velvet
2 Replies
8. Solaris
Hi
Please can you help me on replacing or removing a faulty disk drive on a SUN NETRA X4250server with 4 internal drives only.
the format comand show me the following:
format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
0. c0t0d0 <drive type unknown>
... (9 Replies)
Discussion started by: fretagi
9 Replies
9. Filesystems, Disks and Memory
Hello,
On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active.
We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED.
... (1 Reply)
Discussion started by: terrya
1 Replies
10. AIX
Hello,
On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active.
We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED.
... (3 Replies)
Discussion started by: terrya
3 Replies
LEARN ABOUT HPUX
vximportdg
vximportdg(1M) vximportdg(1M)
NAME
vximportdg - import a disk group into the Veritas Volume Manager configuration
SYNOPSIS
vximportdg daname new_dgname
DESCRIPTION
The vximportdg utility performs a temporary import of the disk group contained on the disk device specified by daname to the disk group
specified by new_dgname. As the persistent disk group information is not changed within the private partition of the affected disk, the
import is only valid for the duration of the bootload or until a vxdg deport is performed.
ARGUMENTS
daname Specifies the device name (disk access name) of one of the member disks of the disk group to be imported. The other members are
imported automatically.
new_dgname
Specifies the disk group to be imported.
USAGE
One reason to use the vximportdg utility is to import a second generation of the rootdg disk group so that its objects are available for
use while a system is running on a different rootdg. To prevent volumes on the second generation rootdg from having the same device minor
numbers as volumes (such as rootvol) on the active rootdg, the importation assigns temporary non-conflicting device minor numbers. If this
occurs, vximportdg outputs warning messages detailing the mapping of the minor numbers.
SEE ALSO
vxdg(1M)
VxVM 5.0.31.1 24 Mar 2008 vximportdg(1M)