Hey
if its for the server you logged in into then use the following command, hope it'll help you out !!

prtconf

for more options of this command, please refer to "man prtconf".

Or as era said "last" will be efficient to do your task over.


Thanks
Varun GuptaSmilie
 

10 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Changing Machine IP address

Hopefully someone can help with this. I need the command to change the IP address on a machine (7 Replies)
Discussion started by: kkinnon
7 Replies

2. UNIX for Dummies Questions & Answers

Restricting access to a machine by IP Address

I have a need to allow only certain IP addresses to access a machine running solaris 9. I am not sure how this can be accomplished. Thanks in advance for your help. Patch (2 Replies)
Discussion started by: patch
2 Replies

3. Programming

How to get IP Address of machine?

Is there any API call to get IP Address of a machine? I know there is function which returns name of the machine, gethostname(). But I need the IP. Thanks & Regards, Ahsan (7 Replies)
Discussion started by: Ahsan
7 Replies

4. IP Networking

how to retrieve IP address of a machine

hi is there is any command that retrieves the IP address of a machine. Also is there any function in c that does the same. thankx (5 Replies)
Discussion started by: mridula
5 Replies

5. Shell Programming and Scripting

How to get Windows machine's IP address from Unix?

I am using windows Xp. From windows I would connect to my IBM AIX unix machine using telnet client. Is there any command available to view the IP address of Windows machine from Unix? (Note that ifconfig will give unix mahcine's IP address currently logged in.) (3 Replies)
Discussion started by: mvictorvijayan
3 Replies

6. UNIX for Dummies Questions & Answers

IP address of Unix machine

Can any one please tell me how to find the IP address of the Unix machine we are in? (9 Replies)
Discussion started by: thoothukudiking
9 Replies

7. Solaris

How to get the IP address / Host name of client machine

Hi How to get the IP address / Host name of a particular user connected to Unix Server. For example: If used 'DevUser1' is connected to Unix server. I need to find out from which PC this connection has been made. How can this be achieved? Thanks (6 Replies)
Discussion started by: MVL
6 Replies

8. UNIX for Dummies Questions & Answers

Static IP address for solaris 10 virtual machine

Hi All I am having a solaris 10 virtual machine on vista (using vmware 7) laptop. Now i want to access virtual machine from vista using putty. Problem is that i insalled the solaris machine as dhcp. and whenever i connect to internet or reboot my system the IP address of solaris... (1 Reply)
Discussion started by: ankurk
1 Replies

9. Solaris

i want to set ip address to a virtual machine

hi all i want to set ip address to a vitrual machine i am using following command. but it is not ifconfig -a command output. what is wrong i dont know bash# ifconfig interfacename plumb bash# ifconfig interfacename auto-dhcp Please use code tags next time for your code and data. (4 Replies)
Discussion started by: nikhil kasar
4 Replies

10. Programming

I.p address of machine

i m writing a program which finds the i.p address of the machine. but it just prints out the first three character of the ifconfig output but i want to just print my i.p address lik 10.0.0.222 which is in second line after inet addr: code : #include<iostream> #include<cstdlib> using... (1 Reply)
Discussion started by: console
1 Replies
prtconf(1M)															       prtconf(1M)

NAME
prtconf - print system configuration SYNOPSIS
/usr/sbin/prtconf [-V] | [-F] | [-x] | [-bpv] | [-acDPv] [dev_path] The prtconf command prints the system configuration information. The output includes the total amount of memory, and the configuration of system peripherals formatted as a device tree. If a device path is specified on the command line for those command options that can take a device path, prtconf will only display informa- tion for that device node. The following options are supported: -a Display all the ancestors device nodes, up to the root node of the device tree, for the device specified on the command line. -b Display the firmware device tree root properties for the purpose of platform identification. These properties are "name", "compat- ible", "banner-name" and "model". -c Display the device subtree rooted at the device node specified on the command line, that is, display all the children of the device node specified on the command line. -D For each system peripheral in the device tree, displays the name of the device driver used to manage the peripheral. -F Returns the device path name of the console frame buffer, if one exists. If there is no frame buffer, prtconf returns a non-zero exit code. This flag must be used by itself. It returns only the name of the console, frame buffer device or a non-zero exit code. For example, if the console frame buffer on a SUNW,Ultra-30 is ffb, the command returns: /SUNW,ffb@1e,0:ffb0. This option could be used to create a symlink for /dev/fb to the actual console device. -p Displays information derived from the device tree provided by the firmware (PROM) on SPARC platforms or the booting system on platforms.The device tree information displayed using this option is a snapshot of the initial configuration and may not accu- rately reflect reconfiguration events that occur later. -P Includes information about pseudo devices. By default, information regarding pseudo devices is omitted. -v Specifies verbose mode. -V Displays platform-dependent PROM (on SPARC platforms) or booting system (on platforms) version information. This flag must be used by itself. The output is a string. The format of the string is arbitrary and platform-dependent. -x Reports if the firmware on this system is 64-bit ready. Some existing platforms may need a firmware upgrade in order to run the 64-bit kernel. If the operation is not applicable to this platform or the firmware is already 64-bit ready, it exits silently with a return code of zero. If the operation is applicable to this platform and the firmware is not 64-bit ready, it displays a descriptive message on the standard output and exits with a non-zero return code. The hardware platform documentation contains more information about the platforms that may need a firmware upgrade in order to run the 64-bit kernel. This flag overrides all other flags and must be used by itself. The following operands are supported: dev_path The path to a target device minor node, device nexus node, or device link for which device node configuration information is displayed The following exit values are returned: 0 No error occurred. non-zero With the -F option (SPARC only), a non-zero return value means that the output device is not a frame buffer. With the -x option, a non-zero return value means that the firmware is not 64-bit ready. In all other cases, a non-zero return value means that an error occurred. See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWesu | +-----------------------------+-----------------------------+ |Interface Stability |Unstable | +-----------------------------+-----------------------------+ fuser(1M), modinfo(1M), sysdef(1M), attributes(5) Sun Hardware Platform Guide SPARC Only openprom(7D) The output of the prtconf command is highly dependent on the version of the PROM installed in the system. The output will be affected in potentially all circumstances. The driver not attached message means that no driver is currently attached to that instance of the device. In general, drivers are loaded and installed (and attached to hardware instances) on demand, and when needed, and may be uninstalled and unloaded when the device is not in use. On platforms, the use of prtconf -vp provides a subset of information from prtconf -v. The value of integer properties from prtconf -vp might require byte swapping for correct interpretation. 9 Aug 2005 prtconf(1M)
All times are GMT -4. The time now is 08:55 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy