UPS options other than Powertrust for D380

We have a D380 server running 10.20 for disaster recovery in the event we ever needed it. Hardly robust, dual processor, 4 4.3gb HDD, DDS3 tape drive, CD-ROM and external DLT4000 tape drive. Are there any 3rd-party UPS options that anyone could recommend that would provide for graceful shutdown? I've seen APC PowerChute for HP-UX in many weblinks, but have yet to find anyone that actually has the product in stock.

Any help would be appreciated.
 

8 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Newbie UPS help

I am a newbie and I just got a Sun Ultra 5, and want an UPS. I have been looking at the different models, but I do not know which brand has software that is compatable with Solaris 2.8 for automatic shutdown. I have looked at the power setup options in Solaris, but there doesn't seem to be any... (1 Reply)
Discussion started by: jeremiebarber
1 Replies

2. UNIX for Advanced & Expert Users

UPS for HP-9000

Hello Everyone I run 4 HP 9000 servers with HP-UX 11.0 on all 4, with an Infomix Database. About 6 months ago one system starting acting real weird it will display the message that it lost power (which did not) and it would shutdown, Then roughly 30 seconds later it would then say power has... (4 Replies)
Discussion started by: JackieRyan26
4 Replies

3. Solaris

Suns and UPS tripplite

I'm having some trouble getting my ups to work on my Sun ultra enterprise servers. I have it hooked to serial port b and i have the tripplite power alert software installed and running, but it doesn't see the connection, is there something else i'm supposed to do to make it realize it is hooked to... (2 Replies)
Discussion started by: kymberm
2 Replies

4. Solaris

UPS Installation

Dear All, I have installed package ups reillo in solaris but i could not use setup normaly, i could not connection with ttya , i need connect with ups for set system shutdown and another configuration. please i need help for solution thanks. (0 Replies)
Discussion started by: athurbayunata
0 Replies

5. What is on Your Mind?

any goof ups like this?

This thread reminded me of a couple of screwups made by an operator in my old job. The ops used to run OS backups through a script which asked for the path to the tape (/dev/rmt/whatnot). We (the sysadmins) would give these to the ops if a new server was added or the h/w path changed. One Sunday... (4 Replies)
Discussion started by: blowtorch
4 Replies

6. HP-UX

[Solved] D380/2 hard drive

Hello everybody, I've received yesterday a very old HP server: HP9000, A3579A, D380/2 with two 180 MHz PA-RISC CPUs, 256 MB RAM. Actual firmware is 38.40. But no hard drives. I'm looking for 18 or 36 GB HD references. Is 11i v3 HP-UX working on it? Or, what is the latest version? Is 256 MB... (4 Replies)
Discussion started by: Citroen
4 Replies

7. Hardware

CyberPower UPS

Is anyone here using this brand, and if so, how satisfied are you with its 'PowerPanel for Linux' software? Any problems? (0 Replies)
Discussion started by: Varsel
0 Replies

8. What is on Your Mind?

The green pop-ups...

Admins... I just lerve the pop-ups that appear whilst replying to someones post. It reminds me of "Paperclip" from my MS Windows days... ;oDD Love it, as it makes me smile, telling me I am creating a thread ATM... ;o) Neat little addition/feature guys... (4 Replies)
Discussion started by: wisecracker
4 Replies
MT(1)							      General Commands Manual							     MT(1)

NAME
mt - control magnetic tape drive operation SYNOPSIS
mt [-V] [-f device] [--file=device] [--rsh-command=command] [--version] operation [count] DESCRIPTION
This manual page documents the GNU version of mt. mt performs the given operation, which must be one of the tape operations listed below, on a tape drive. The default tape device to operate on is taken from the file /usr/include/sys/mtio.h when mt is compiled. It can be overridden by giving a device file name in the environment variable TAPE or by a command line option (see below), which also overrides the environment variable. The device must be either a character special file or a remote tape drive. To use a tape drive on another machine as the archive, use a filename that starts with `HOSTNAME:'. The hostname can be preceded by a username and an `@' to access the remote tape drive as that user, if you have permission to do so (typically an entry in that user's `~/.rhosts' file). The available operations are listed below. Unique abbreviations are accepted. Not all operations are available on all systems, or work on all types of tape drives. Some operations optionally take a repeat count, which can be given after the operation name and defaults to 1. eof, weof Write count EOF marks at current position. fsf Forward space count files. The tape is positioned on the first block of the next file. bsf Backward space count files. The tape is positioned on the first block of the next file. fsr Forward space count records. bsr Backward space count records. bsfm Backward space count file marks. The tape is positioned on the beginning-of-the-tape side of the file mark. fsfm Forward space count file marks. The tape is positioned on the beginning-of-the-tape side of the file mark. asf Absolute space to file number count. Equivalent to rewind followed by fsf count. seek Seek to block number count. eom Space to the end of the recorded media on the tape (for appending files onto tapes). rewind Rewind the tape. offline, rewoffl Rewind the tape and, if applicable, unload the tape. status Print status information about the tape unit. retension Rewind the tape, then wind it to the end of the reel, then rewind it again. erase Erase the tape. mt exits with a status of 0 if the operation succeeded, 1 if the operation or device name given was invalid, or 2 if the operation failed. OPTIONS -f, --file=device Use device as the file name of the tape drive to operate on. To use a tape drive on another machine, use a filename that starts with `HOSTNAME:'. The hostname can be preceded by a username and an `@' to access the remote tape drive as that user, if you have permission to do so (typically an entry in that user's `~/.rhosts' file). --rsh-command=command Notifies mt that it should use command to communicate with remote devices instead of /usr/bin/ssh or /usr/bin/rsh. -V, --version Print the version number of mt. REPORTING BUGS
Report cpio bugs to bug-cpio@gnu.org GNU cpio home page: <http://www.gnu.org/software/cpio/> General help using GNU software: <http://www.gnu.org/gethelp/> Report cpio translation bugs to <http://translationproject.org/team/> MT(1)
All times are GMT -4. The time now is 03:10 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy