Hi there

Following my success installing SCO openserver 5.0.7 on an HP ML350 G5 last time, I have been instructed to install the same 5.0.7 on an HP ML310 G5.

The ML310 G5 have the same RAID array as the ML350 (HP E200 SATA RAID) but the hard drives are larger (3x160Gb and 1x250Gb spare).

First I created a logical drive with the full space available (262Gb) but SCO refused to see the full extend of the logical drive free space. It only see less than 5Gb.Smilie

Then I deleted the logical drive, and created two logical drives on the same array, one of 160Gb and the rest with the remainder of the free space.

SCO installed well, and all seems to be working fine (network etc).

But there still is an unused second logical drive, how can I enable SCO to see and use that?

I understand that I have to use mkdev hd to create an entry in /dev for fdisk to use, but mkdev hd only works for ide or scsi and not for sata... and I'm Smilie as to what I am to do now at this stage.

Any help will be welcome Smilie

Thanks in advance

Regards


Libs

Last edited by The_Librarian; 04-04-2008 at 06:47 AM..
 

2 More Discussions You Might Find Interesting

1. Homework & Coursework Questions

Print questions from a questions folder in a sequential order

1.) I am to write scripts that will be phasetest folder in the home directory. 2.) The folder should have a set-up,phase and display files I have written a small script which i used to check for the existing users and their password. What I need help with: I have a set of questions in a... (19 Replies)
Discussion started by: moraks007
19 Replies

2. UNIX for Advanced & Expert Users

Sendmail questions, SCO 5.0.6 sendmail 8.11.0

I am running SCO 5.0.6 and using sendmail 8.11.0 and having issues with smtp authentication. When trying to send mail the following message will kick back. (reason: 530 5.7.1 Authentication required) 530 5.7.1 Authentication required Not sure what needs to be tweeked in sendmail.cf but I... (1 Reply)
Discussion started by: ziggy6
1 Replies
array-info(1)															     array-info(1)

NAME
array-info - check the status of a HP (Compaq) SmartArray controller SYNOPSIS
array-info -d array_device_path [-a|-l|-A|-c|-s|-L|-h] DESCRIPTION
Array-info is a command line tool to retrieve informations and logical drives status from several RAID controllers (currently HP Compaq IDA and CISS and MD). It displays informations about the firmware version, Rom revision, number of physical and logical drives on the con- troller, aswell as the fault tolerance, size, number of physical disks and status for each logical drive. OPTIONS
--device | -d Path to array device, e.g. /dev/ida/c0d0 or /dev/cciss/c0d1 --all-drives | -a Show informations about all drives --logical drive | -l Show informations about selected logical drive --show-ctrl | -c Show informations about controller --show-logical | -L Show informations about logical drives --show-physical | -p Show physical device informations --show-status | -s Show status of logical drives --show-all | -A Show all informations --version | -V Show version -h Show help about options COPYRIGHT