Operating Systems AIX san luns controller problem Post 302180761 by Sprellarinn on Tuesday 1st of April 2008 05:13:26 AM
Old 04-01-2008
When you have DS4* disk arrays AIX uses the rDAC driver which has the limitation that it can only see one path to the disks per host bus adapter in the machine, that is fsc0 can only be zoned against controler 1 on the disk box and fsc1 against controler 2. If this is not the case, but the fsc0 zoned against both controler 1 and 2, and the same for fsc1 - these situations can ariese. I have selved had such an situation myself which was resolved by rmdev -dl on all the devices, correcting the zoning and cfgmgr again.
 

10 More Discussions You Might Find Interesting

1. Linux

problem with disks on SAN

Hi I have a linux box attched to a SAN storage from EMC with RAID 5 .I understand that it has 3g cache howver a 20gb file creation takes too much time here are my results any ideas why time dd if=/dev/zero of=disk.img bs=1048576 count=20000 20000+0 records in 20000+0 records out 997.59s... (2 Replies)
Discussion started by: xiamin
2 Replies

2. Solaris

Thoughts/experiences of SAN attaching V880 to EMC SAN

Hi everyone, I wonder if I can canvas any opinions or thoughts (good or bad) on SAN attaching a SUN V880/490 to an EMC Clarion SAN? At the moment the 880 is using 12 internal FC-AL disks as a db server and seems to be doing a pretty good job. It is not I/O, CPU or Memory constrained and the... (2 Replies)
Discussion started by: si_linux
2 Replies

3. Solaris

Problem with accessing SAN disks

Hi, I'm having a problem when attempting to define the OCR location for my 10g RAC setup on Solaris 10. I get the following error: The specified shared raw partition /dev/did/rdsk/d1s0 may not have the correct permission. Verify that the partition is owned by Oracle user. As per the Oracle10g... (15 Replies)
Discussion started by: michael.chow
15 Replies

4. HP-UX

Target LUNs plus que deux sur un SAN de 2 fabrics

salut admin, Normalement mon serveur doit voir un de mes LDEV à partir de deux chemins sur le SAN et ainsi lui attribuer seulement deux Target LUNs. Or il lui en a attribué 8!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! Très bizzare! Auriez vous une idée. Merci pour votre aide appréciée (2 Replies)
Discussion started by: hmaiida
2 Replies

5. Solaris

need help for removing SAN LUNS on solaris 9

Hi I would like to remove SAN luns from system and do not want them even after system reboot, format Searching for disks...done df -kh I know last 4 partitions are from SAN but there could be more. Can someone please help me correct steps to remove SAN Luns. vxdisk list ... (2 Replies)
Discussion started by: upengan78
2 Replies

6. Hardware

Problem with External Raid Controller.

Hi, We have a Sunfire 4150 with On-Board Internal Raid Controller connected to 4 X 146 GB SAS disks. This also has an External Raid Controller (Storagetek Eight-Port, External HBA Model SG-XPCIESAS-R-EXT-Z) connected to a JBOD array ( Storagetek XTA2530 ) which has 5 X 300 GB Hard disk. ... (1 Reply)
Discussion started by: ranjansukumar
1 Replies

7. UNIX and Linux Applications

Controller problem: Error calling DSRunJob

Hi I got this error : Controller problem: Error calling DSRunJob(JOBNAME.), code=-2 can some tell me, what it means? (0 Replies)
Discussion started by: Avi
0 Replies

8. Solaris

SAN-based LUNs

running Solaris10 with Qlogic FC adapters connected to a multi-host FC array..using VXFS/VXVM.. Is there in Solaris10 or using some Qlogic drivers to filter out only the LUNs this host can see ?? Normally this is done by LUN masking in the FC switch or the FC array itself..however, neither... (2 Replies)
Discussion started by: ppchu99
2 Replies

9. Solaris

Are these SAN LUNs really not mounted?

Hello everyone. I've been asked to check if something is wrong with the storage setup on these two SunOS 5.10 machines, which are being used as database servers with Oracle RAC configuration. Seems to be that the DB guy is complaining, telling that they are nearly out of space, which sounds... (4 Replies)
Discussion started by: kacareu
4 Replies

10. Filesystems, Disks and Memory

Faster way: SAN hd to SAN hd copying

hi! i got a rhel 6.3 host that already have an xfs filesystem mounted from a SAN (let's call it SAN-1) whose size is 9TB. i will be receiving another SAN (let's call it SAN-2) storage of 15TB size. this new addition is physically on another SAN storage. SAN-1 is on a Pillar storage while the new... (6 Replies)
Discussion started by: rino19ny
6 Replies
vxpfto(1M)																vxpfto(1M)

NAME
vxpfto - set Powerfail Timeout (pfto) SYNOPSIS
vxpfto -g diskgroup -t timeout vxpfto [-g diskgroup] -t timeout volume_list vxpfto [-g diskgroup] -o pftostate={enabled|disabled} vxpfto [-g diskgroup] -o pftostate={enabled|disabled} volume_list DESCRIPTION
Powerfail Timeout is an attribute of a SCSI disk connected to an HP-UX host (see the pfto(7) man page). The vxpfto command sets the Power- fail Timeout interval on a set of Volume Manager disks, either all disks in a disk group, or all disks underlying the volumes listed. The first form of the command sets the same PFTO value for all the disks in the specified VxVM diskgroup. In the second form, all disks underlying the given list of volumes are selected, optionally restricted by the disk group specified with the -g option. If you specify a diskgroup, any volume in the list not belonging to the diskgroup is ignored. Use the -o pftostate option to disable or enable PFTO. By default, PFTO is enabled. You can enable PFTO either on all disks in a disk group, or on all disks underlying the volumes listed. If you invoke vxpfto without arguments, it displays a usage message. OPTIONS
-g diskgroup Specifies the disk group for the operation, either by disk group ID or by disk group name. -o pftostate={enabled|disabled} Enables or disables the use of PFTO for IO. -t timeout Specifies the PFTO value in seconds. The value must be zero or a positive integer. Zero represents the system default PFTO value. The default value depends on the disk driver controlling the disk device. volume_list A list of VxVM volume names. List items must be separated by white-space. EXIT CODES
vxpfto returns a zero if successful. If it encounters an error, vxpfto exits and displays a message on standard error. Defined exit codes are: 0 Success. 1 No PFTO value specified. 2 No diskgroup or volume list specified. 3 Illegal PFTO value specified. EXAMPLES
Set the PFTO value on all disks in disk group testdg to 100 seconds: vxpfto -t 100 -g testdg Set the PFTO value to 50 seconds on all disks underlying volume01 and volume02 in disk group testdg: vxpfto -t 50 -g testdg volume01 volume02 Set the PFTO value to 300 seconds on all disks underlying volume01 and volume02, even though they are not in the same disk group: vxpfto -t 300 volume01 volume02 Disable PFTO on all disks in disk group testdg: vxpfto -g testdg -o pftostate=disabled Enable PFTO on all disks underlying volume01 and volume02i in disk group testdg: vxpfto -g testdg -o pftostate=enabled volume01 volume02 SEE ALSO