Sponsored Content
Operating Systems SCO master and slave in lan network Post 302170266 by hossein on Monday 25th of February 2008 04:09:36 AM
Old 02-25-2008
master and slave in lan network

hello , i setup a lan network , but i don't know how configure master and slave in the lan network please help meSmilie
 

8 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

NIS master / slave problems

Our NIS master server went down. We have since fixed it and brought it back up. However all of are machines still point to the slave server when looking at it with ypwhich. My question is how do i point the servers back to the master. Frank (2 Replies)
Discussion started by: frankkahle
2 Replies

2. UNIX for Dummies Questions & Answers

print a file on a network printer from one lan to another

Hi, I have 2 different lan, each with a pc an a network printer. I can access both lan using ssh. how do I print a file from the first lan to a network printer on the second one. Thanks in advance Philippe sorry it was suposed to go to the dummies forum (3 Replies)
Discussion started by: amazilia
3 Replies

3. Web Development

MySQL Master-Slave Configuration: Don't Replicate a Row of a Table?

Anyone have a clue about this? I have checked the MySQL documentation and it does not seem possible to exclude a row of a table from replication between Master and Slave. It seems that replication in MySQL can only be managed at the table level, not at the row level. Does anyone know a work... (5 Replies)
Discussion started by: Neo
5 Replies

4. Programming

Asynchronous communication between master and slave threads

I am writing a process that has a master thread and a set of slave threads. Master thread is supposed to get jobs dynamically and assign to slave thread which is free. Master also get results back from slaves once a job is done. The number of slaves should be adjustable dynamically based on job... (1 Reply)
Discussion started by: tamil.pamaran
1 Replies

5. UNIX Desktop Questions & Answers

How can I replicate master master and master master MySQL databse replication and HA?

I have an application desigend in PHP and MySQl running on apache web server that I is running on a Amazon EC2 server Centos. I want to implement the master-master and master slave replication and high availability disaster recovery on this application database. For this I have created two... (0 Replies)
Discussion started by: Palak Sharma
0 Replies

6. Programming

How to wait the slave to be finished first then execute the master--MPI C++?

Hi, How to wait the slave to be finished first then execute the master? Can someone give me the specific function? Or the detailed example. Thanks~ (1 Reply)
Discussion started by: wanliushao
1 Replies

7. IP Networking

DNS question about initial Master/Slave setup

Hey everyone. I'm creating a DNS master/slave server set up. I have the configurations all done I believe, the master has the required zone file, and the named.conf file has the allow transfer and allow query stuff set. The slave has it's own configs set. My question is that when initially... (1 Reply)
Discussion started by: Lost in Cyberia
1 Replies

8. UNIX for Beginners Questions & Answers

Why inactive slave bonding received network package in redhat?

bond0 active in eth0 and inactive in eth4. why eth4 received network package? Bonding Mode: fault-tolerance (active-backup) Primary Slave: eth0 (primary_reselect failure) Currently Active Slave: eth0 MII Status: up MII Polling Interval (ms): 100 Up Delay (ms): 0 Down Delay (ms): 0 ... (4 Replies)
Discussion started by: samran35
4 Replies
MODBUS_SET_SLAVE(3)						 Libmodbus Manual					       MODBUS_SET_SLAVE(3)

NAME
modbus_set_slave - set slave number in the context SYNOPSIS
int modbus_set_slave(modbus_t *ctx, int slave); DESCRIPTION
The modbus_set_slave() function shall set the slave number in the libmodbus context. The behavior depends of network and the role of the device: RTU Define the slave ID of the remote device to talk in master mode or set the internal slave ID in slave mode. According to the protocol, a Modbus device must only accept message holing its slave number or the special broadcast number. TCP The slave number is only required in TCP if the message must reach a device on a serial network. The special value MODBUS_TCP_SLAVE (0xFF) can be used in TCP mode to restore the default value. The broadcast address is MODBUS_BROADCAST_ADDRESS. This special value must be use when you want all Modbus devices of the network receive the request. RETURN VALUE
The modbus_set_slave() function shall return 0 if successful. Otherwise it shall return -1 and set errno to one of the values defined below. ERRORS
EINVAL The slave number is invalid. AUTHORS
The libmodbus documentation was written by Stephane Raimbault <stephane.raimbault@gmail.com[1]> NOTES
1. stephane.raimbault@gmail.com mailto:stephane.raimbault@gmail.com libmodbus 3.0.3 05/26/2012 MODBUS_SET_SLAVE(3)
All times are GMT -4. The time now is 08:46 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy