Operating Systems Solaris Solaris installation Post 302169613 by jlliagre on Thursday 21st of February 2008 05:27:08 PM
Old 02-21-2008
It might be a disk issue, a controller issue, a BIOS configuration issue or a driver issue.
You can try installing Solaris Express build 81 or newer as a similar report was fixed that way.
 

9 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Solaris Installation

Each and every time I tried to install Solaris 8 on my Dell Dimension (Intel P II - 400 MHz processor) the system hangs up. I am not able to load the Operating System at all. The same software works on other PC(different make). If anyone has a solution, please let me know. (6 Replies)
Discussion started by: vpedditi
6 Replies

2. Solaris

installation of Solaris: installation bypasses network config.

hello solaris friends, I've tried installing Sun Solaris 10.0, but everytime it seems to bypass the network config. screen that looks similar to this...here's the url: http://www.hup.hu/old/images/hup/Solaris/Sol10beta7/9.png I'm able to install it all the way through but I get no... (2 Replies)
Discussion started by: cadmiumgreen
2 Replies

3. Solaris

Solaris 10 Installation

Firstly, I'm still new to all the technical of OS. But I'm learning. Hence I am starting to explore Unix via Solaris 10. Today, I backed up all my files and formatted my computer. I only have one physical hard drive of about 250GB. So unpartitioned all my exisiting drives and start my... (5 Replies)
Discussion started by: Xannen
5 Replies

4. Solaris

Solaris Installation

Hi, I want to know as we can install Sun Solaris through hyperterminal,Wheather any other software is coming through which we can install sun solaris (1 Reply)
Discussion started by: manoj.solaris
1 Replies

5. Solaris

new installation Solaris

hi guys im totally new to Solaris - i can use it for some functions (like at work) but installing is a first for me - please dont flame if there are any stupid questions; allright, my set up is a gigabyte motherboard which is supposed to work (BigAdmin - HCL: Gigabyte GA-MA790GP-DS4H ) 4... (5 Replies)
Discussion started by: Landser
5 Replies

6. Solaris

Solaris Installation

Hi all, I have a question.... Where can we find the default log locations and can identify the number of CD's installed in the system on Sparc and Intel Machines???? Thanks (4 Replies)
Discussion started by: tirupathiraju_t
4 Replies

7. Solaris

Solaris installation

i want to install solaris 10 in my server ... can u please guide me.. (6 Replies)
Discussion started by: senkerth
6 Replies

8. Solaris

Solaris 10 flash installation - fatal error. Solaris installation program exited.

Not very helpful to say the least. Seems to read the flar file and go through the upgrade and then come up with this error. Any ideas? (1 Reply)
Discussion started by: psychocandy
1 Replies

9. Solaris

Installation of Solaris 10 1/13

Hi, I am doing a fresh installation of Solaris 10 1/13 on an IBM x3550 M3 server (x86). When I begin the installation it shows me failed to mount zfs, I was advised by oracle to ignore that. After the installation has finished and I reboot,I get a host of random errors after that it displays... (1 Reply)
Discussion started by: spirited67
1 Replies
AMR(4)							   BSD Kernel Interfaces Manual 						    AMR(4)

NAME
amr -- MegaRAID SCSI/ATA/SATA RAID driver SYNOPSIS
To compile this driver into the kernel, place the following lines in your kernel configuration file: device pci device scbus device amr Alternatively, to load the driver as a module at boot time, place the following line in loader.conf(5): amr_load="YES" DESCRIPTION
The amr driver provides support for LSI Logic MegaRAID SCSI, ATA and SATA RAID controllers and legacy American Megatrends MegaRAID SCSI RAID controllers, including models relabeled and sold by Dell and Hewlett-Packard. LSI MegaRAID SAS controllers are supported by mfi(4) and will not work with this driver. HARDWARE
Controllers supported by the amr driver include: o MegaRAID SATA 150-4 o MegaRAID SATA 150-6 o MegaRAID SATA 300-4X o MegaRAID SATA 300-8X o MegaRAID SCSI 320-1E o MegaRAID SCSI 320-2E o MegaRAID SCSI 320-4E o MegaRAID SCSI 320-0X o MegaRAID SCSI 320-2X o MegaRAID SCSI 320-4X o MegaRAID SCSI 320-0 o MegaRAID SCSI 320-1 o MegaRAID SCSI 320-2 o MegaRAID SCSI 320-4 o MegaRAID Series 418 o MegaRAID i4 133 RAID o MegaRAID Elite 1500 (Series 467) o MegaRAID Elite 1600 (Series 493) o MegaRAID Elite 1650 (Series 4xx) o MegaRAID Enterprise 1200 (Series 428) o MegaRAID Enterprise 1300 (Series 434) o MegaRAID Enterprise 1400 (Series 438) o MegaRAID Enterprise 1500 (Series 467) o MegaRAID Enterprise 1600 (Series 471) o MegaRAID Express 100 (Series 466WS) o MegaRAID Express 200 (Series 466) o MegaRAID Express 300 (Series 490) o MegaRAID Express 500 (Series 475) o Dell PERC o Dell PERC 2/SC o Dell PERC 2/DC o Dell PERC 3/DCL o Dell PERC 3/QC o Dell PERC 4/DC o Dell PERC 4/IM o Dell PERC 4/SC o Dell PERC 4/Di o Dell PERC 4e/DC o Dell PERC 4e/Di o Dell PERC 4e/Si o Dell PERC 4ei o HP NetRAID-1/Si o HP NetRAID-3/Si (D4943A) o HP Embedded NetRAID o Intel RAID Controller SRCS16 o Intel RAID Controller SRCU42X DIAGNOSTICS
Driver initialisation/shutdown phase amr%d: memory window not available amr%d: I/O window not available The PCI BIOS did not allocate resources necessary for the correct operation of the controller. The driver cannot attach to this controller. amr%d: busmaster bit not set, enabling The PCI BIOS did not enable busmaster DMA, which is required for the correct operation of the controller. The driver has enabled this bit and initialisation will proceed. amr%d: can't allocate register window amr%d: can't allocate interrupt amr%d: can't set up interrupt amr%d: can't allocate parent DMA tag amr%d: can't allocate buffer DMA tag amr%d: can't allocate scatter/gather DMA tag amr%d: can't allocate s/g table amr%d: can't allocate mailbox tag amr%d: can't allocate mailbox memory A resource allocation error occurred while initialising the driver; initialisation has failed and the driver will not attach to this con- troller. amr%d: can't obtain configuration data from controller amr%d: can't obtain product data from controller The driver was unable to obtain vital configuration data from the controller. Initialisation has failed and the driver will not attach to this controller. amr%d: can't establish configuration hook amr%d: can't scan controller for drives The scan for logical drives managed by the controller failed. No drives will be attached. amr%d: device_add_child failed amr%d: bus_generic_attach returned %d Creation of the logical drive instances failed; attachment of one or more logical drives may have been aborted. amr%d: flushing cache... The controller cache is being flushed prior to shutdown or detach. Operational diagnostics amr%d: I/O beyond end of unit (%u,%d > %u) A partitioning error or disk corruption has caused an I/O request beyond the end of the logical drive. This may also occur if FlexRAID Vir- tual Sizing is enabled and an I/O operation is attempted on a portion of the virtual drive beyond the actual capacity available. amr%d: polled command timeout An initialisation command timed out. The initialisation process may fail as a result. amr%d: bad slot %d completed The controller reported completion of a command that the driver did not issue. This may result in data corruption, and suggests a hardware or firmware problem with the system or controller. amr%d: I/O error - %x An I/O error has occurred. SEE ALSO
cd(4), da(4), mfi(4), sa(4), scsi(4) AUTHORS