Hi,
I have the situaiton in which primary boot disk has bad sectors in Solaris 9. The other hard disk is mirrored using Solstice DiskSuite 4.2. I can reboot system with the other disk. My question is, when I replaced the boot disk with a new one, how can I create meta db and finally make it... (2 Replies)
Hi,
We had a disk go bad in this SunFire 280R, running Solaris 8 - Generic_117350-46. We replaced the disk and partitioned it. We metadetached all the metadevices but for some reason the new disk is showing up in the metadb as Concat/Stripe and it won't let us re-sync the mirror. We are not... (2 Replies)
The following is the summarry:-
1) Four disks in server ie (c1t0d0. c1t1d0, c1t2d0, c1t3d0). c1t2d0 is the disk to be replaced.
c1t0d0 and c1t2d0 are mirrors.
c1t1d0 and c1t3d0 are mirrors.
Metadb to be deleted is in c1t2d0s7
a) Mirror d35 has 2 submirrors d38 and d39
d38 is a stripe... (0 Replies)
Hi Admins,
I am new into aix.I was surfing aix pages and reading how to replace failed mirror disks.I read in one of the posts that we have to reboot the server to replace the disk. actually i was a HPUX admin and many times replaced root mirror disk online.Ofcourse it was hot swappable.
... (2 Replies)
First a little background: I'm working with an AIX 6.1 TL05 running two mirrored SAS disks (rootvg) and four SSDs (appvg)
All four SSDs belong to appvg and are setup to mirror as follows:
hdisk4 --> hdisk6 (containing application fs)
hdisk5 --> hdisk7 (containing database fs)
A few days... (1 Reply)
I have a v480 with a mirrored boot disk c1t0 and c1t1. The drives themselves don't show a failure but the mirror's need maintenance.
This is my plan for replacing the drive. I would love feedback to point out what I"m missing or where my steps are incorrect.
Two things I believe I'm... (3 Replies)
Hi All
BAsed on the below I would like to verifu two things
(1) The udnerlying mirroris for '/mnt' na dit onlcy contaisne 1 sub-mirror, with one sliceon is one disk and hence, data loss on the mount point (the mount point, '/mnt' is backed up)
(2) the Procedure for renewal
# df -kh /mnt... (2 Replies)
Hi
Please can you help me on replacing or removing a faulty disk drive on a SUN NETRA X4250server with 4 internal drives only.
the format comand show me the following:
format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
0. c0t0d0 <drive type unknown>
... (9 Replies)
Discussion started by: fretagi
9 Replies
LEARN ABOUT SUSE
irsend
IRSEND(1) FSF IRSEND(1)NAME
irsend - basic LIRC program to send infra-red commands
SYNOPSIS
irsend [options] DIRECTIVE REMOTE CODE [CODE...]
DESCRIPTION
Asks the lircd daemon to send one or more CIR (Consumer Infra-Red) commands. This is intended for remote control of electronic devices such
as TV boxes, HiFi sets, etc.
DIRECTIVE can be:
SEND_ONCE - send CODE [CODE ...] once
SEND_START - start repeating CODE
SEND_STOP - stop repeating CODE
LIST - list configured remote items
SET_TRANSMITTERS - set transmitters NUM [NUM ...]
SIMULATE - simulate IR event
REMOTE is the name of a remote, as described in the lircd configuration file.
CODE is the name of a remote control key of REMOTE, as it appears in the lircd configuration file.
NUM is the transmitter number of the hardware device.
For the LIST DIRECTIVE, REMOTE and/or CODE can be empty:
LIST "" "" - list all configured remote names
LIST REMOTE "" - list all codes of REMOTE
LIST REMOTE CODE - list only CODE of REMOTE
The SIMULATE command only works if it has been explicitly enabled in lircd.
-h --help
display usage summary
-v --version
display version
-d --device
use given lircd socket [/var/run/lirc/lircd]
-a --address=host[:port]
connect to lircd at this address
-# --count=n
send command n times
EXAMPLES
irsend LIST DenonTuner ""
irsend SEND_ONCE DenonTuner PROG-SCAN
irsend SEND_ONCE OnkyoAmpli VOL-UP VOL-UP VOL-UP VOL-UP
irsend SEND_START OnkyoAmpli VOL-DOWN ; sleep 3
irsend SEND_STOP OnkyoAmpli VOL-DOWN
irsend SET_TRANSMITTERS 1
irsend SET_TRANSMITTERS 1 3 4
irsend SIMULATE "0000000000000476 00 OK TECHNISAT_ST3004S"
FILES
/etc/lirc/lircd.conf
Default lircd configuration file. It should contain all the remotes, their infra-red codes and the corresponding timing and wave-
form details.
DIAGNOSTICS
If lircd is not running (or /var/run/lirc/lircd lacks write permissions) irsend aborts with the following diagnostics:
"irsend: could not connect to socket"
"irsend: Connection refused" (or "Permission denied").
SEE ALSO
The documentation for lirc is maintained as html pages. They are located under html/ in the documentation directory.
lircd(8), mode2(1), smode2(1), xmode2(1), irrecord(1), irw(1), http://www.lirc.org.
irsend 0.8.7pre1 May 2010 IRSEND(1)