Sponsored Content
Operating Systems HP-UX "ps -o" Not valid: XPG4 Only. What does that mean? Post 302167763 by goldfish on Friday 15th of February 2008 12:56:19 PM
Old 02-15-2008
Quote:
Originally Posted by Tytalus
hmmm - been a long time...try setting the ENV variable

UNIX95=

(that's UNIX95=<space>)

e.g.:

Code:
UNIX95= ps -o comm,sz,vsz,time,user,uid

Whoo, nice! That worked!
I've done a bit of googling on UNIX95 to try and understand it. The solution seen most often is
alias ps="UNIX95= /usr/bin/ps"

Another solution I tried was using a perminate variable:
$export UNIX95=
$ps -o comm
which worked... Is this a better solution? or is this going to have unforseen(potentially bad) effects on the other HP Unix core utilities?

Thanks,
Gold Fish
 

8 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Explain the line "mn_code=`env|grep "..mn"|awk -F"=" '{print $2}'`"

Hi Friends, Can any of you explain me about the below line of code? mn_code=`env|grep "..mn"|awk -F"=" '{print $2}'` Im not able to understand, what exactly it is doing :confused: Any help would be useful for me. Lokesha (4 Replies)
Discussion started by: Lokesha
4 Replies

2. Shell Programming and Scripting

cat $como_file | awk /^~/'{print $1","$2","$3","$4}' | sed -e 's/~//g'

hi All, cat file_name | awk /^~/'{print $1","$2","$3","$4}' | sed -e 's/~//g' Can this be done by using sed or awk alone (4 Replies)
Discussion started by: harshakusam
4 Replies

3. AIX

"rmt0" is not a valid backing device - VIO

hello to all, i am trying to assing a tape drive to a virtual partition through VIO but i get the message "rmt0" is not a valid backing device. the oslevel of my VIO is AIX 6.1.3.0. when i run the command lsdev |grep rmt i get the following result: rmt0 Available 08-08-00-0,0 ... (6 Replies)
Discussion started by: omonoiatis9
6 Replies

4. Shell Programming and Scripting

awk command to replace ";" with "|" and ""|" at diferent places in line of file

Hi, I have line in input file as below: 3G_CENTRAL;INDONESIA_(M)_TELKOMSEL;SPECIAL_WORLD_GRP_7_FA_2_TELKOMSEL My expected output for line in the file must be : "1-Radon1-cMOC_deg"|"LDIndex"|"3G_CENTRAL|INDONESIA_(M)_TELKOMSEL"|LAST|"SPECIAL_WORLD_GRP_7_FA_2_TELKOMSEL" Can someone... (7 Replies)
Discussion started by: shis100
7 Replies

5. Shell Programming and Scripting

Help with error "por: 0403-012 A test command parameter is not valid."

Hi, im asking for help with the next script: echo ^; then if then printf "\033 query1.sh: export TERM=vt100 export ORACLE_TERM=at386 export ORACLE_HOME=/home_oracle8i/app/oracle/product/8.1.7 export ORACLE_BASE=/home_oracle8i/app/oracle export... (8 Replies)
Discussion started by: blacksteel1988
8 Replies

6. UNIX for Dummies Questions & Answers

Using "mailx" command to read "to" and "cc" email addreses from input file

How to use "mailx" command to do e-mail reading the input file containing email address, where column 1 has name and column 2 containing “To” e-mail address and column 3 contains “cc” e-mail address to include with same email. Sample input file, email.txt Below is an sample code where... (2 Replies)
Discussion started by: asjaiswal
2 Replies

7. Shell Programming and Scripting

Bash script - Print an ascii file using specific font "Latin Modern Mono 12" "regular" "9"

Hello. System : opensuse leap 42.3 I have a bash script that build a text file. I would like the last command doing : print_cmd -o page-left=43 -o page-right=22 -o page-top=28 -o page-bottom=43 -o font=LatinModernMono12:regular:9 some_file.txt where : print_cmd ::= some printing... (1 Reply)
Discussion started by: jcdole
1 Replies

8. AIX

Apache 2.4 directory cannot display "Last modified" "Size" "Description"

Hi 2 all, i have had AIX 7.2 :/# /usr/IBMAHS/bin/apachectl -v Server version: Apache/2.4.12 (Unix) Server built: May 25 2015 04:58:27 :/#:/# /usr/IBMAHS/bin/apachectl -M Loaded Modules: core_module (static) so_module (static) http_module (static) mpm_worker_module (static) ... (3 Replies)
Discussion started by: penchev
3 Replies
standards(5)							File Formats Manual						      standards(5)

NAME
standards - UNIX standards behavior on HP-UX DESCRIPTION
HP-UX conforms to various UNIX standards. In some cases, these standards conflict. This manpage describes the methods that programmers and users must follow to have an application conform and execute according to a particular UNIX standard. UNIX Standard Conformant Programmer Environment The following table lists feature test macros and environment variables that must be defined while compiling an application. Both a fea- ture test macro and an environment variable must be defined while compiling the application so that the application conforms and executes according to a particular UNIX standard. Otherwise, the behavior is undefined. Standard Feature Test Macros to be Environment variable defined during compilation to be set UNIX 95 _XOPEN_SOURCE_EXTENDED=1 UNIX95 or UNIX_STD=95 or UNIX_STD=1995 UNIX 2003 _XOPEN_SOURCE=600 UNIX_STD=2003 The compiler uses the feature test macros to obtain the appropriate namespace from the header files. The compiler uses the environment variable to link in an appropriate object file to the executable. Using the environment variable customizes libc to match UNIX standards for various functions. If an application has already been compiled for default HP-UX behavior or for one particular standard, and needs to change to a particular UNIX standard behavior, recompile the application as specified in the above table. For an HP-UX command to conform to a particular UNIX standard behavior, the application has to set the corresponding environment variable as specified in the above table before executing that command. UNIX Standard Conformant User Environment To enable a particular UNIX standard conformant user environment, set the corresponding environment variable as defined in the above table. EXAMPLES
The following examples shows an application example. To have the system be conformant to UNIX2003 behavior, set the environment variable to and define the feature test macro before compilation. The following example changes the command to have UNIX95 behavior by setting one of the environment variables to or to before executing that command. There are three ways of setting the environment variable for UNIX95: or or SEE ALSO
cc(1), stdsyms(5). standards(5)
All times are GMT -4. The time now is 03:53 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy