Operating Systems Solaris Sun Blade 100 Disk Compatibility Post 302166699 by System Shock on Tuesday 12th of February 2008 02:10:12 PM
Old 02-12-2008
...first thing you do, you tone down the sarcasm. You aren't paying for the help here.
...second, ATA drives and SATA drives are not the same thing.

IDE is IDE, regardless on which architecture they run.
 

10 More Discussions You Might Find Interesting

1. Solaris

sun Blade 2000 and XVR100

hello, I have SunBlade 2000 with XVR-1000 graphics card. Xserver won't loaded. I've reinstalled OS 9 ( loaded Driver) nor 10 still won't do it. Anyone has this problem or have any ideas whats' wrong, greatly appreciated!! thanks in adv. (1 Reply)
Discussion started by: anphdula
1 Replies

2. Solaris

Clone disk for Sun Blade 2000

Hai ......... my name Rio, I want to clone my harddisk at Sun Balade 2000 server with Solaris 8 OS, my question is : a. what kind method for making backup or clonning disk ? b. what method more easier , quick but still reliable ? c. how to proceed it ? Thanks (1 Reply)
Discussion started by: rioria
1 Replies

3. UNIX for Dummies Questions & Answers

sun blade 100 test-all frozen at pci@1f,0/usb/c,3

platform: sunblade 100 Solaris 10. When running a test-all from the ok prompt on this new (to me) system, it locks up at pci@1f,0/usb/c,3. It's been there for about 25 minutes. I do have a usb keyboard and mouse attached, both are known good. There is no flash stick/ thumb drive... (0 Replies)
Discussion started by: montana77
0 Replies

4. Solaris

Sun Blade 100 Memory Upgrade

Hi, I've been a member for a while but have never posted. I have a Sun Blade 100 desktop and I just installed Solaris 10 and it is unbearably slow. I only have 128 Meg of RAM and need to upgrade. I have searched and found many online resources that have RAM, but I was wondering if anyone has... (12 Replies)
Discussion started by: BrewDudeBob
12 Replies

5. Solaris

Sun Blade 100 cdrom problems...

FYI noob to here and sun blades... I have a sun blade 100 and I can't get the cdrom to work. if i try using vold that doesn't seem to work either...maybe i'm not using it correctly. Upon boot you can open/close the cdrom and it runs but after i'm logged in it won't open and i can't access it... (2 Replies)
Discussion started by: shaun138
2 Replies

6. UNIX for Dummies Questions & Answers

Serial Connection sun blade 100 to pc

Hi, If someone please help as my efforts been exhausted in connecting my sun blade 100 serial to my pc. I am using null modem with DB9(female) in sun blade and DB9(female, using gender change) in pc. I am trying both hyper/putty 9600 8 N 1 configurations. Thanks (2 Replies)
Discussion started by: younics
2 Replies

7. Solaris

Sun Blade 150 not a Sun?

I have recently re-installed Solaris 10 on a Sun Blade 150 followed by a patch set (10_Recommended) dated 2011.12.05. I have just noticed /bin/sun now returns false, rather than true. See below. $ uname -a SunOS myblade1 5.10 Generic_147440-07 sun4u sparc SUNW,Sun-Blade-100 $ /bin/sparc &&... (1 Reply)
Discussion started by: apmcd47
1 Replies

8. UNIX for Dummies Questions & Answers

Reinstalling Solaris 9 on Sun Blade 100

For the past ten years I have owned a blade 100, and I had Solaris 9 running on it. Due to the fact, 9 is woefully out of date, I wanted to try 10, but 10 needed more ram, so I beefed up the ram to the full 2 gig. I have two 15 gig ide drives in the box (stock drives). But unfortunately solaris... (2 Replies)
Discussion started by: RichardET
2 Replies

9. Solaris

help installing solaris 10 on sun blade 1500

Hi everyone can someone please explain to me how to install solaris 10 on a sunblade 1500 using cdrom? Thanks for your assistance (1 Reply)
Discussion started by: cjashu
1 Replies

10. UNIX for Dummies Questions & Answers

SUN BLADE T6340 - which OS ?

Hi, I have server SUN BLADE T6340 and i tried install debian sparc on this machine. Will it work ? In the specification is written only Solaris 10. (4 Replies)
Discussion started by: PtaQ
4 Replies
scdpm(1M)						  System Administration Commands						 scdpm(1M)

NAME
scdpm - manage disk path monitoring daemon SYNOPSIS
scdpm [-a] {node | all} scdpm -f filename scdpm -m {[node | all][:/dev/did/rdsk/]dN | [:/dev/rdsk/]cNtXdY | all} scdpm -n {node | all} scdpm -p [-F] {[node | all][:/dev/did/rdsk/]dN | [/dev/rdsk/]cNtXdY | all} scdpm -u {[node | all][:/dev/did/rdsk/]dN | [/dev/rdsk/]cNtXdY | all} DESCRIPTION
Note - Beginning with the Sun Cluster 3.2 release, Sun Cluster software includes an object-oriented command set. Although Sun Cluster software still supports the original command set, Sun Cluster procedural documentation uses only the object-oriented command set. For more infor- mation about the object-oriented command set, see the Intro(1CL) man page. The scdpm command manages the disk path monitoring daemon in a cluster. You use this command to monitor and unmonitor disk paths. You can also use this command to display the status of disk paths or nodes. All of the accessible disk paths in the cluster or on a specific node are printed on the standard output. You must run this command on a cluster node that is online and in cluster mode. You can specify either a global disk name or a UNIX path name when you monitor a new disk path. Additionally, you can force the daemon to reread the entire disk configuration. You can use this command only in the global zone. OPTIONS
The following options are supported: -a Enables the automatic rebooting of a node when all monitored disk paths fail, provided that the following conditions are met: o All monitored disk paths on the node fail. o At least one of the disks is accessible from a different node in the cluster. You can use this option only in the global zone. Rebooting the node restarts all resource and device groups that are mastered on that node on another node. If all monitored disk paths on a node remain inaccessible after the node automatically reboots, the node does not automatically reboot again. However, if any monitored disk paths become available after the node reboots but then all monitored disk paths again fail, the node automatically reboots again. You need solaris.cluster.device.admin role-based access control (RBAC) authorization to use this option. See rbac(5). -F If you specify the -F option with the -p option, scdpm also prints the faulty disk paths in the cluster. The -p option prints the cur- rent status of a node or a specified disk path from all the nodes that are attached to the storage. -f filename Reads a list of disk paths to monitor or unmonitor in filename. You can use this option only in the global zone. The following example shows the contents of filename. u schost-1:/dev/did/rdsk/d5 m schost-2:all Each line in the file must specify whether to monitor or unmonitor the disk path, the node name, and the disk path name. You specify the m option for monitor and the u option for unmonitor. You must insert a space between the command and the node name. You must also insert a colon (:) between the node name and the disk path name. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -m Monitors the new disk path that is specified by node:diskpath. You can use this option only in the global zone. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -n Disables the automatic rebooting of a node when all monitored disk paths fail. You can use this option only in the global zone. If all monitored disk paths on the node fail, the node is not rebooted. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). -p Prints the current status of a node or a specified disk path from all the nodes that are attached to the storage. You can use this option only in the global zone. If you also specify the -F option, scdpm prints the faulty disk paths in the cluster. Valid status values for a disk path are Ok, Fail, Unmonitored, or Unknown. The valid status value for a node is Reboot_on_disk_failure. See the description of the -a and the -n options for more information about the Reboot_on_disk_failure status. You need solaris.cluster.device.read RBAC authorization to use this option. See rbac(5). -u Unmonitors a disk path. The daemon on each node stops monitoring the specified path. You can use this option only in the global zone. You need solaris.cluster.device.admin RBAC authorization to use this option. See rbac(5). EXAMPLES
Example 1 Monitoring All Disk Paths in the Cluster Infrastructure The following command forces the daemon to monitor all disk paths in the cluster infrastructure. # scdpm -m all Example 2 Monitoring a New Disk Path The following command monitors a new disk path.All nodes monitor /dev/did/dsk/d3 where this path is valid. # scdpm -m /dev/did/dsk/d3 Example 3 Monitoring New Disk Paths on a Single Node The following command monitors new paths on a single node. The daemon on the schost-2 node monitors paths to the /dev/did/dsk/d4 and /dev/did/dsk/d5 disks. # scdpm -m schost-2:d4 -m schost-2:d5 Example 4 Printing All Disk Paths and Their Status The following command prints all disk paths in the cluster and their status. # scdpm -p schost-1:reboot_on_disk_failure enabled schost-2:reboot_on_disk_failure disabled schost-1:/dev/did/dsk/d4 Ok schost-1:/dev/did/dsk/d3 Ok schost-2:/dev/did/dsk/d4 Fail schost-2:/dev/did/dsk/d3 Ok schost-2:/dev/did/dsk/d5 Unmonitored schost-2:/dev/did/dsk/d6 Ok Example 5 Printing All Failed Disk Paths The following command prints all of the failed disk paths on the schost-2 node. # scdpm -p -F all schost-2:/dev/did/dsk/d4 Fail Example 6 Printing the Status of All Disk Paths From a Single Node The following command prints the disk path and the status of all disks that are monitored on the schost-2 node. # scdpm -p schost-2:all schost-2:reboot_on_disk_failure disabled schost-2:/dev/did/dsk/d4 Fail schost-2:/dev/did/dsk/d3 Ok EXIT STATUS
The following exit values are returned: 0 The command completed successfully. 1 The command failed completely. 2 The command failed partially. Note - The disk path is represented by a node name and a disk name. The node name must be the host name or all. The disk name must be the global disk name, a UNIX path name, or all. The disk name can be either the full global path name or the disk name: /dev/did/dsk/d3 or d3. The disk name can also be the full UNIX path name: /dev/rdsk/c0t0d0s0. Disk path status changes are logged with the syslogd LOG_INFO facility level. All failures are logged with the LOG_ERR facility level. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWsczu | +-----------------------------+-----------------------------+ |Stability |Evolving | +-----------------------------+-----------------------------+ SEE ALSO
Intro(1CL), cldevice(1CL), clnode(1CL), attributes(5) Sun Cluster System Administration Guide for Solaris OS Sun Cluster 3.2 22 Jun 2006 scdpm(1M)
All times are GMT -4. The time now is 07:37 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy