Sponsored Content
Full Discussion: system manager on 10
Operating Systems Solaris system manager on 10 Post 302165917 by Perderabo on Saturday 9th of February 2008 10:56:02 PM
Old 02-09-2008
smc, I guess. smc man page But it is new with 10 and I have never used it. Speaking of new, I hear that HP has deprecated sam in favor of a new program called smh. I have never used that either.
 

7 More Discussions You Might Find Interesting

1. AIX

"Web-based System Manager" error

Hi, I have a problem with the "Web-based System Manager" on AIX 5.3 ML04. When selecting category "File Systems" and the "Overview and Tasks", I get a popup with the following error: : com.ibm.jcb.RemoteSourceException: The remote call failed; nested exception is:... (1 Reply)
Discussion started by: Ebbi
1 Replies

2. Solaris

Sun N1 System Manager installation ??

Hi, Is there any easy way to install Sun N1 System Manager ?? I was trying to install it on Solaris 9 but when I run the install file (./install) it says "Perl version must be greater than or equal 5.8 !! how can I disply the perl version also how can update perl ? any advice for a good... (1 Reply)
Discussion started by: ArabOracle.com
1 Replies

3. AIX

Web-based System Manager (WSM)

Hello everyone, Would any of you know what group I need to be a member of to be able to change system settings via WSM? I have tried adding myself to couple of groups (adm, sucurity, system) but so far no good. I am able to see what settings are applied, but cannot change them. Thanks in... (3 Replies)
Discussion started by: juniorG
3 Replies

4. AIX

web-based system manager

dear aix guru, i have some question....i would like to set up broadcast message & email to root repeatly when the event had occured untill the error is fixed.... coz i got only one broadcast message & email when i start the condition... thanks ;) (0 Replies)
Discussion started by: click007
0 Replies

5. AIX

Starting web-based system manager?

How does one initiate this? (1 Reply)
Discussion started by: NycUnxer
1 Replies

6. Solaris

RAID manager or veritas volume manager

Can somebody kindly help me to determine which one i should choose to better manipulate OS volume. RAID manager or veritas volume manager? Any critical differences between those two? Thanks in advance. (5 Replies)
Discussion started by: beginningDBA
5 Replies

7. AIX

Monitoring AIX with System Center Operation Manager 2007 R2

I can get my AIX servers to show up in SCOM but I'm struggling with running personal scripts and have the result of these scripts show up in SCOM. I'm currently using BigBrother and I've written some scripts for BB. I would like to convert these scripts to something that can be used in SCOM. ... (0 Replies)
Discussion started by: petervg
0 Replies
SMCINIT(8)							    Linux IrDA								SMCINIT(8)

NAME
smcinit - initialize the SMSC IrDA controler on various laptops SYNOPSIS
smcinit [OPTIONS] DESCRIPTION
Toshiba Satellite 1800, Satellite 5100, Tecra 9100 laptops and may be many other models are provided with a SMCS LPC47N227 SuperIO chip which is IrDA SIR/FIR capable. The IrDA subsystem of the SuperIO chip is supported by the smc-ircc Linux kernel module. Unfortunately the BIOS neither configurates the SuperIO chip IrDA subsystem (SIR port, FIR port, dma, irq, IrDA mode, power) nor sets the PCI-ISA bridge to decode any usable port. Linux kernel is thus prevented to detect the second UART making impossible to use it in SIR mode. For the same reason, the FIR mode smc-ircc is able to detect the SuperIO chip but, once found the IrDA subsystem unconfigured, fails to install. While this problem will be fixed in Linux 2.6.x kernel series, the 2.4.x users are frustrated. Daniele Peri, Rob Miller and Paul Hampson mananged to build little utilities that initialize the LPC47N227 SuperIO allowing smc-ircc IrDA kernel driver to detect and use the SMSC chip. My sole work was to put these utilities as one package, easy to install and use. OPTIONS
-V, --version Show program version and exit -h, --help Show a little help on options and exit -v, --verbose Increase the details about actions performed -t, --tty=device If specified, the serial device will be unbound from the kernel stock serial driver. It is there to replace an external call to setse- rial(1) to unset the UART of the device. There is no default value. -s, --sirio=IO Set the SIR (serial infrared) I/O port address to IO. Default value is 0x3f8. -f, --firio=IO Set the FIR (fast infrared) I/O port address to IO. Default value is 0x130. -i, --firirq=IRQ Set the FIR (fast infrared) IRQ line to IRQ. Default value is 3. -d, --firdma=DMA Set the FIR (fast infrared) DMA channel to DMA. Default value is 3. CONFIGURATION
When system startup a script is run from /etc/init.d and which run appropriate SMC intialization utility. This is done before PCMCIA startup because on Tecra 9100 and other models the orinoco_cs wireless driver will block the I/O region used 47N227 SuperIO. The only configuration file is /etc/sysconfig/smcinit and the variable SMCCONFIG can be set to "1800" or "5100". By default "5100" value is used. 1800 for Toshiba Satellite 1800 5100 for Toshiba Satellite 5100 and Toshiba Tecra 9100 The next step is to configure the kernel IrDA stack package to attach the smc-ircc driver. This is Linux distribution specific. The main thing is that the device should be set to "irda0". Run the following command: irattach irda0 -s Distribution specific configuration: SuSE Edit the /etc/sysconfig/irda and set IRDA_PORT=irda0 RedHat Edit the /etc/sysconfig/irda and set DEVICE=irda0 NOTES
The smc-ircc driver is preloaded in kernel. I tested the package only on Tecra 9100 without any additional step, but for Toshiba Satellite 1800 Daniele Peri sugest to put the following line in your /etc/modules.conf (on one line): options smc-ircc ircc_dma=3 ircc_irq=7 ircc_cfg=0x2e ircc_sir=0x2e8 ircc_fir=0x2f8 After that run the command: prompt# depmod -a If the laptop enter suspend mode, then resume operation the smc-ircc driver will stop working. You need to stop IrDA service, then SMCINIT, start SMCINIT, and finally start IrDA service. Simply put, the kernel driver must be unloaded, then reloaded. FILES
/etc/sysconfig/smcinit Configuration file for SMCINIT startup script. It's shell script. AUTHOR
This document is made by Claudiu Costin <claudiuc@kde.org> The utilities authors are Daniele Peri, Rob Miller and Paul Hampson. Thomas Pinz made improvements to tosh-smcinit (the former tosh5100-smcinit) to expand the number of Toshiba Satellite models supported. SEE ALSO
smcinit(7), tosh1800-smcinit(8), irattach(1), irdadump(1), http://irda.sourceforge.net/smcinit/ the SMCINIT package home page. 0.4 April 2004 SMCINIT(8)
All times are GMT -4. The time now is 06:27 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy