Operating Systems Solaris Find server details Post 302164318 by lalelle on Monday 4th of February 2008 12:18:41 PM
Old 02-04-2008
Find server details

Hi experts
Is there a command or a way in Solaris to find server details like this:

SUN240R
2 @ 160MHz CPU
1Gb memory
Solaris8
lan0 (16SV LAN) 100FD
lan1 (45CI LAN) 100FD
lan2 (8CON LAN) 10HD
lan3 (38SY LAN) 100HD


Thanks
 

9 More Discussions You Might Find Interesting

1. Red Hat

How to find the os and h/w details

Hi Need to know the version(suse/redhat) and processor info(x86/itanium/amd etc). I tried uname -a but cannot understand what is what... Linux myworkhost 2.4.21-4.ELsmp #1 SMP Fri Oct 3 17:52:56 EDT 2003 i686 i686 i386 GNU/Linux I dont have the root password, I can only ssh and have to... (3 Replies)
Discussion started by: amiri2000
3 Replies

2. Filesystems, Disks and Memory

how to find out unix server details

I like to find out Server Drive/Storage Specifications like Drive Size? Storage Type: Local or SAN ? Number of Processors: Processor Speed: Memory: please someone help me out how I can get from command line? Thanks you in advance (4 Replies)
Discussion started by: thopputhurai
4 Replies

3. Solaris

Some Details from my server like mirror

Hello, I need to get some details from my server like Internal hard disk details for my UNIX (Solaris 9) server like whether OS is mirrored or not, what type of mirror is used. Which hard disk are used for mirror ? Regards (1 Reply)
Discussion started by: adel8483
1 Replies

4. Shell Programming and Scripting

Directory details with FIND

Hello, an easy question, I hope. What would be the way to produce a result from the following find statement that would also include for each line in the output the details usually associated with the ls -ltr command? Here is the find I am using: find . -name "*.prg" -exec grep "test line" {}... (4 Replies)
Discussion started by: gio001
4 Replies

5. HP-UX

HP-UX Server Details

OS: HP-UX I need the following details from HP-UX server. I don't have root login, so most of the commands require root privilege 1. No of cpu in the server 2. Total Memory, Free & Used 3. Space used and free space Any help would be highly appreciated (6 Replies)
Discussion started by: manijash
6 Replies

6. Solaris

Need some help to find out hardware details

hi all i am looking for some command or utility to find out hard ware details. 1. How should i know whether my network adapter is a fibre card or RJ25 (upd) card (ethtool in linux) 2. How to check physical connectivity. ("mii-tool eth0" in linux) 3. How to find pci devices with exact details.... (1 Reply)
Discussion started by: kingston
1 Replies

7. Shell Programming and Scripting

Geographical location details of a server

Is there a way to find geographical location details of a server in shell scripting ? Say, which region server is located at etc. (5 Replies)
Discussion started by: blp_18
5 Replies

8. Solaris

How to find MQ details on Solaris 5.8?

Hi All, I want to find MQ details on a solaris 5.8 server , does anyone knows the command to findout the details I have used below command to find the following o/p command pkginfo | grep -i mq o/p application mqm WebSphere MQ for Sun Solaris application... (4 Replies)
Discussion started by: Jcpratap
4 Replies

9. Shell Programming and Scripting

How to find a file with a specific pattern for current sysdate & upon find email the details?

I need assistance with following requirement, I am new to Unix. I want to do the following task but stuck with file creation date(sysdate) Following is the requirement I need to create a script that will read the abc/xyz/klm folder and look for *.err files for that day’s date and then send an... (4 Replies)
Discussion started by: PreetArul
4 Replies
LES(8)							       Maintenance Commands							    LES(8)

NAME
les, bus - ATM LAN Emulation service demons SYNOPSIS
les [-d module] [-m module] [-f configuration_file] bus [-d module] [-m module] [-f configuration_file] DESCRIPTION
LE Service consists of three components: LAN Emulation Configuration Server (lecs(8)), LAN Emulation Server (les) and Broadcast and Unknown Server (bus). Les performs the control coordination function for the emulated LAN. LE clients register MAC addresses and/or route descriptors they rep- resent to les, and later query it when they want to resolve MAC addresses/route descriptors into ATM addresses. Other LE control messages which are to be distributed to every client in ELAN are also sent to les. Les forwards these messages using Control Distribute VCC which it has set up to every client in ELAN. Bus handles data sent by clients to broadcast and multicast MAC addresses and some of the data directed to unicast addresses. LE Client has a possibility to send data directed to some unicast address to the bus before target's ATM address has been resolved and the Data Direct VCC has been established. Configuration file example for les and bus: [main] memdebug=True debug=True [load] #memdebug=True #debug=True [conn] debug=True #S1, LE Server's ATM address #S1=:47:00:23:00:00:00:03:00:00:01:00:02:01:00:20:ea:00:05:aa:00 S1=:47:00:23:00:00:00:03:03:00:01:00:02:01:00:20:ea:00:0a:e9:01 #S2, LAN Type S2="802.3" #S3, Maximum Frame Size S3=1516 #S4, Join Timeout, s S4=15 #S5, Maximum Frame Age, s S5=6 #S6, BUS Atm address S6=:47:00:23:00:00:00:03:03:00:01:00:02:01:00:20:ea:00:0a:e9:02 #viulu #S6=0,0,170 #ELANNAME="asdf" The configuration file contains each modules name in brackets followed by variable definitions for that module. The definitions are of form variable=value, where value can be either an integer, a truth value (True/False), a string enclosed in double quotes ("string") or an ATM address in hexadecimal format. Variables that can be set are the debug/memdebug for each module and variables S1-S6 as defined in LE speci- fication. S1=Address of the LES. This address is used in ATM signalling. S2=Type of the emulated LAN. Valid values is "802.3". S3=Maximum frame size. Valid value is 1516. S4=Join Timeout. Time in seconds which LES waits for LE_JOIN_REQUEST before tearing down a connection. S5=Maximum frame Age. Currently not used. S6=Address of the BUS. This address is used in ATM signalling. ELANNAME= Name of the emulated LAN SIGHUP causes restart of the server. All resources are released and server is started. SIGUSR1 causes the server to dump its internal state. SIGUSR2 shuts down the server (hopefully) gracefully. OPTIONS
-d module Set debugging messages on for a module. "All" sets debugging on for all modules. -m module Set memory debugging messages on for a module. "All" sets debugging on for all modules. -f configuration_file Use the specified configuration file instead of .lanevars. FILES
.lanevars configuration file BUGS
Servers don't establish point-to-multipoint connections to LE clients as the specification states, which means that some LE clients won't work with these servers. Supports only IEEE 802.3 / Ethernet type of ELANs. This manual page is confusing. AUTHOR
Marko Kiiskila, TUT <carnil@cs.tut.fi> SEE ALSO
lecs(8), atmsigd(8), zeppelin(8) Linux Sep 11, 1996 LES(8)
All times are GMT -4. The time now is 07:04 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy