Sponsored Content
Full Discussion: Install Fibre Card AIX 5.3
Operating Systems AIX Install Fibre Card AIX 5.3 Post 302161034 by chlawren on Wednesday 23rd of January 2008 12:23:35 PM
Old 01-23-2008
the answer ....

ensure your system is at the correct OS level

determine mpio or datapath devices

SAN configuration and hardware to be determined.

install drivers
shut down the box
install the card
cable up
turn server on
configure san
run cfgmgr

in a nutshell .....

unless someone else has any other tips ....
 

9 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

X Server on AIX w/o video card

Hi there, I'm a newbie so please be patient. I wanted to know if it was possible to run X server on a box w/o a video card. The reason I want to do this is I'd like to have a CDE session from sun workstation into the AIX box. Please let me know if this is feasible. Thanks for your time. (5 Replies)
Discussion started by: blah00000
5 Replies

2. Solaris

Unable to install the Network Card

Hi, After I installed Solaris 10 in the Intel platform (chipset 865*) network card was not detected, were shall I get this driver? iam new to Solaris. (2 Replies)
Discussion started by: pravin_2929
2 Replies

3. Debian

Kernel source not found. (can't install network card drivers)

I've had no luck with help on linuxquestions so I figured I'd try here. I'm using debian etch. The problem is that I can not install my network card because it says: Makefile:62: *** Linux kernel source not found. Stop. I have the kernel-headers installed. I've looked all over the... (9 Replies)
Discussion started by: Virtuality
9 Replies

4. AIX

Fibre channel drivers on RS/6000 aix 5L

Want to configure IBM raid strorage but the aix 5L cds do not have the drivers for the fibre channels. The machine is RS/6000. I have gone to IBM downlaodable sites but i can't find the drivers? help pliz:mad: (4 Replies)
Discussion started by: Zim-Aix-Guru
4 Replies

5. Solaris

Install Solaris 10 with an internal StorageTek SAS HBA Raid card

Hi all i would like to ask some suggests about my next job! I have to install a new Sun Netra T5220, with an additional internal StorageTek SAS HBA Raid. The problem come in if every disk is now controlled by the HBA, how can I install the OS? No disk is being detected by the OS. SAS card... (2 Replies)
Discussion started by: kakabobo
2 Replies

6. UNIX for Dummies Questions & Answers

How to install a network card

Hey guys, Sorry, this question might look stupid but I have no idea how to install a network card. My server is a Dell PowerEdge T105 with Debian 5.0 Lenny. My network card is a Broadcom NetXtreme BCM5722 Gigabit Ethernet PCI Express. I've plugged the card innside my server and I can see... (2 Replies)
Discussion started by: chebarbudo
2 Replies

7. War Stories

How not to install fibre links between data centres!

Hi Folks, A couple of years ago we had to replace the core switches between two of our data centres, a simple task for the most part - these new switches would be state of the art Cisco Catalyst units. The link between the two sites was a dark fibre, with 8Gb bandwidth running full duplex... (9 Replies)
Discussion started by: gull04
9 Replies

8. AIX

AIX - Fibre Adapter and IBM Storage

Hello, Just a quick question Usually from a PSERIES if you want to connect to IBM SAN Storage you connect the IBM SAN Storage through a SAN Switch something like this --- however my question Can you connect from Pseries directly to San Storage without SAN Switch what would be... (8 Replies)
Discussion started by: filosophizer
8 Replies

9. AIX

[ASK] - AIX Fibre Channel behavior

Hello all, Let me introduce about the context and my environment. We have an AIX 6.1 system, it has 4 FC channels / > lsdev -Cc adapter | grep fcs fcs0 Available 23-T1 Virtual Fibre Channel Client Adapter fcs1 Available 23-T1 Virtual Fibre Channel Client Adapter fcs2 Available 23-T1... (14 Replies)
Discussion started by: Phat
14 Replies
ovs-dpctl(8)							Open vSwitch Manual						      ovs-dpctl(8)

NAME
ovs-dpctl - administer Open vSwitch datapaths SYNOPSIS
ovs-dpctl [options] command [switch] [args...] DESCRIPTION
The ovs-dpctl program can create, modify, and delete Open vSwitch datapaths. A single machine may host up to 256 datapaths (numbered 0 to 255). A newly created datapath is associated with only one network device, a virtual network device sometimes called the datapath's ``local port''. A newly created datapath is not, however, associated with any of the host's other network devices. To intercept and process traf- fic on a given network device, use the add-if command to explicitly add that network device to the datapath. If ovs-vswitchd(8) is in use, use ovs-vsctl(8) instead of ovs-dpctl. Most ovs-dpctl commands that work with datapaths take an argument that specifies the name of the datapath. Datapath names take the form [type@]name, where name is the network device associated with the datapath's local port. If type is given, it specifies the datapath provider of name, otherwise the default provider system is assumed. The following commands manage datapaths. add-dp dp [netdev[,option]...] Creates datapath dp, with a local port also named dp. This will fail if a network device dp already exists. If netdevs are specified, ovs-dpctl adds them to the new datapath, just as if add-if was specified. del-dp dp Deletes datapath dp. If dp is associated with any network devices, they are automatically removed. add-if dp netdev[,option]... Adds each netdev to the set of network devices datapath dp monitors, where dp is the name of an existing datapath, and netdev is the name of one of the host's network devices, e.g. eth0. Once a network device has been added to a datapath, the datapath has complete ownership of the network device's traffic and the network device appears silent to the rest of the system. A netdev may be followed by a comma-separated list of options. The following options are currently supported: type=type Specifies the type of port to add. The default type is system. key=value Adds an arbitrary key-value option to the port's configuration. ovs-vswitchd.conf.db(5) documents the available port types and options. set-if dp port[,option]... Reconfigures each port in dp as specified. An option of the form key=value adds the specified key-value option to the port or over- rides an existing key's value. An option of the form key=, that is, without a value, deletes the key-value named key. The type of a port cannot be changed, so type=type is only allowed if type is the port's existing type. del-if dp netdev... Removes each netdev from the list of network devices datapath dp monitors. dump-dps Prints the name of each configured datapath on a separate line. [-s | --statistics] show [dp...] Prints a summary of configured datapaths, including their datapath numbers and a list of ports connected to each datapath. (The local port is identified as port 0.) If -s or --statistics is specified, then packet and byte counters are also printed for each port. If one or more datapaths are specified, information on only those datapaths are displayed. Otherwise, ovs-dpctl displays informa- tion about all configured datapaths. dump-flows dp Prints to the console all flow entries in datapath dp's flow table. This command is primarily useful for debugging Open vSwitch. The flow table entries that it displays are not OpenFlow flow entries. Instead, they are different and considerably simpler flows maintained by the Open vSwitch kernel module. del-flows dp Deletes all flow entries from datapath dp's flow table. This command is primarily useful for debugging Open vSwitch. As discussed in dump-flows, these entries are not OpenFlow flow entries. By deleting them, the process that set them up may be confused about their disappearance. OPTIONS
-s, --statistics Causes the show command to print packet and byte counters for each port within the datapaths that it shows. -t, --timeout=secs Limits ovs-dpctl runtime to approximately secs seconds. If the timeout expires, ovs-dpctl will exit with a SIGALRM signal. -vmodule[:facility[:level]], --verbose=module[:facility[:level]] Sets the logging level for module in facility to level: o module may be any valid module name (as displayed by the --list action on ovs-appctl(8)), or the special name ANY to set the logging levels for all modules. o facility may be syslog, console, or file to set the levels for logging to the system log, the console, or a file respec- tively, or ANY to set the logging levels for both facilities. If it is omitted, facility defaults to ANY. Regardless of the log levels set for file, logging to a file will not take place unless --log-file is also specified (see below). o level must be one of off, emer, err, warn, info, or dbg, designating the minimum severity of a message for it to be logged. If it is omitted, level defaults to dbg. See ovs-appctl(8) for a definition of each log level. -v, --verbose Sets the maximum logging verbosity level, equivalent to --verbose=ANY:ANY:dbg. -vPATTERN:facility:pattern, --verbose=PATTERN:facility:pattern Sets the log pattern for facility to pattern. Refer to ovs-appctl(8) for a description of the valid syntax for pattern. --log-file[=file] Enables logging to a file. If file is specified, then it is used as the exact name for the log file. The default log file name used if file is omitted is /var/log/openvswitch/ovs-dpctl.log. -h, --help Prints a brief help message to the console. -V, --version Prints version information to the console. SEE ALSO
ovs-appctl(8), ovs-vswitchd(8) Open vSwitch August 2009 ovs-dpctl(8)
All times are GMT -4. The time now is 07:57 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy