I have been ask to write a script to show what phyical disks are linked to what luns. By host name. I was hoping someone had some ideas on how to do this. I am from a linux background and am struggling a bit here...lol...I have been given one command to help me out....lsmap..Anyhelp would be nice...
 

9 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Unix map?

There is a "Map"? of Unix and all its varients somewhere on the net. I used to have the link , but can't find it now. Anyone out there have a clue???? A good magician never reveals his secret; the unbelievable trick becomes simple and obvious once it is explained. So too with... (3 Replies)
Discussion started by: Bodhi
3 Replies

2. Red Hat

How get more LUN info

Hello, I'm trying to help a guy out on a VMWARE server, running what looks like a cut down version of redhat? 2.4.9-vmnix2 ... Bascially the box serves vm clients via allocating a LUN from a SAN.. to cut a long story short, I need to find out which SAN the luns are comming from (could be 1... (0 Replies)
Discussion started by: itsupplies
0 Replies

3. UNIX for Dummies Questions & Answers

how to get disks info in solaris9

hi: I know its a dummy question do you have any idea how i can get information about the HDs I have on my solaris server?? like how many disks and the size of each?? the prtdiag doesnt tell about disks. Thanks (8 Replies)
Discussion started by: aladdin
8 Replies

4. Solaris

LUN / Diskgroup info

Hi, I was just about to decommission a box when a weird question paused the operation. This box has veritas volume manager installed. I was umounting all the vx volumes and deleting the disk groups so that the storage admin can take back the LUNS. Now this is where i am stuck - i see a disk... (0 Replies)
Discussion started by: s4g3
0 Replies

5. Solaris

I have LUN ID, how to find disk relate to that LUN ID?

I have a list of LUN ID, my task is to find if disk has been added or not. How do I do that? I have been searching the forum and not able to find answer. thanks (4 Replies)
Discussion started by: uuontario
4 Replies

6. Solaris

Solaris raw disks info

Hi, I need the following information. 1. We have raw disks but how to identify raw disks. Is there any command to identify its type and size. 2. How to differentiate between disks which are used as file system and that are still available to be used as raw. I know we can use df -n to... (7 Replies)
Discussion started by: malikshahid85
7 Replies

7. Programming

Map Question C++

Hello All, I am having an issue of putting a Boolean value in the maps as the 3rd parameter. Something like the following : int value; std::map<String str, int x, bool bl> where bool returns false if x>value else true. All I see in the map examples is that I can add the... (2 Replies)
Discussion started by: mind@work
2 Replies

8. Solaris

Restore of Netapp FC lun targets used as the disks for a zpool with exported zfs file systems

So, We have a Netapp storage solution. We have Sparc T4-4s running with LDOMS and client zones in the LDOMS, We are using FC for storage comms. So here's the basic setup FC luns are exported to the primary on the Sparc box. using LDM they are then exported to the LDOM using vdisk. at the... (4 Replies)
Discussion started by: os2mac
4 Replies

9. Solaris

Solaris 10 Sparc. How to change Vendor info of SAN disks reported in "format" command?

Greetings! After block level migration using an external appliance, the luns are getting reported as DGC-RAID5 and these luns are infact from the new storage. I have a query on changing the device Vendor info from DGC-RAID5 to HP3par in the format o/p only. AVAILABLE DISK SELECTIONS: ... (3 Replies)
Discussion started by: n_Bhaskar
3 Replies
fcd_disable_mgmt_lun(5) 					File Formats Manual					   fcd_disable_mgmt_lun(5)

NAME
fcd_disable_mgmt_lun - select whether or not management luns are discovered in the legacy representation of mass storage devices VALUES
Failsafe Default Allowed values Enable discovery of management luns for array devices. Disable discovery of management luns for array devices. Recommended values DESCRIPTION
Management luns provide the means to access the control ports of Fibre Channel disk arrays. They are represented in both the legacy and the agile view of storage devices. The legacy representation of a management lun is typically created under a separate virtual extension bus node. The entry for a legacy management lun looks like this: On a system with a large number of storage devices connected, creation of management luns can result in an insufficient number of virtual extension buses for the legacy representation of data luns. Since the number of extension buses on a system is limited to 256, luns requiring virtual extension buses above 256 will be unusable through legacy device special files. Disabling the discovery and creation of management luns will free up virtual extension buses for use by data luns. The default value for this tunable is Who Is Expected to Change This Tunable? System administrators who expect to use a large number of storage devices requiring more than 256 extension buses through legacy device special files. Restrictions on Changing Changes to this tunable take effect immediately. However, existing management luns will not be removed. When Should the Tunable Be Turned On? This tunable should be turned on when the system runs out of extension buses for configuring the legacy representation of data luns. What Are the Side Effects of Turning the Tunable Off? None. When Should the Tunable Be Turned Off? When the functionality provided by the management lun is desired. What Are the Side Effects of Turning the Tunable On? Existing management luns in the legacy representation will show up in the state. What Other Tunables Should Be Changed at the Same Time? None. WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of HP-UX. Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation, some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun- able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was factory installed on your system, see at AUTHOR
was developed by Hewlett-Packard Company. SEE ALSO
ioinit(1M), ioscan(1M), kctune(1M). Tunable Kernel Parameters fcd_disable_mgmt_lun(5)
All times are GMT -4. The time now is 02:26 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy