Originally Posted by moofoo
hello there,
there are a few sun sparc server which "allready" support hardware raids
for instance FireT1000, T2000, T5120 or T5220. (setup done with the raidctl command). Also as allready mentioned above raidz (zfs raid) is a good alternative to that.
cheers
but (afaik) this is not a real hardware raid! better use an external raid-box with fcal or scsi controller...
 

9 More Discussions You Might Find Interesting

1. Solaris

how to hardware RAID 1 on T5120

Hi, I have t5120 sparc and I have 2 146 G drives in the system. I will be installing solaris 10 and also want the system mirrored using Hardware RAID "1" The System did come preinstalled as it comes from sun. I did not do much on it. I booted system using boot cdrom -s gave format... (6 Replies)
Discussion started by: upengan78
6 Replies

2. Solaris

T2000 Hardware RAID

Hi, I have a root with hardware RAID on c0t0d0 and c0t2d0. I would like to set the boot device sequence in OBP for both hdds. I have checked in ls -l /dev/rdsk/ for the path of c0t2d0 but it does not exist. Can anyone shed some lights on this? AVAILABLE DISK SELECTIONS: 0.... (12 Replies)
Discussion started by: honmin
12 Replies

3. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

4. Solaris

Hardware Raid - LiveUpgrade

Hi, I have a question. Do LiveUpgrade supports hardware raid? How to choose the configuration of the system disk for Solaris 10 SPARC? 1st Hardware RAID-1 and UFS 2nd Hardware RAID-1 and ZFS 3rd SVM - UFS and RAID1 4th Software RAID-1 and ZFS I care about this in the future to take... (1 Reply)
Discussion started by: bieszczaders
1 Replies

5. Hardware

Sun T3-1 hardware RAID

Hi all I've just received my T3-1. It has 8 disks and I would like to configure RAID1 on the disks. The Sun documentation states that you can either use the OpenBoot PROMP utility called Fcode or you can use software via the Solaris OS. The documentation doesn't make it clear if: 1. The... (6 Replies)
Discussion started by: soliberus
6 Replies

6. HP-UX

Hardware RAID in HP Unix rp3440

Hi Gurus, Can anyone tell me the Hardware RAID configuration in HP Unix rp3440 model server containing HP UX B.11.11 OS version. Thanks in Advance. BR, Prasanth (3 Replies)
Discussion started by: prasanth438
3 Replies

7. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

8. Solaris

Hardware raid patching

Dear All , we have hardware raid 1 implemented on Solaris Disks. We need to patch the Servers. Kindly let me know how to patch hardware raid implemented Servers. Thanks... Rj (7 Replies)
Discussion started by: jegaraman
7 Replies

9. Solaris

Hardware RAID using three disks

Dear All , Pl find the below command , # raidctl -l Controller: 1 Volume:c1t0d0 Disk: 0.0.0 Disk: 0.1.0 Disk: 0.3.0 # raidctl -l c1t0d0 Volume Size Stripe Status Cache RAID Sub Size ... (10 Replies)
Discussion started by: jegaraman
10 Replies
MDMON(8)						      System Manager's Manual							  MDMON(8)

NAME
mdmon - monitor MD external metadata arrays SYNOPSIS
mdmon CONTAINER [NEWROOT] OVERVIEW
The 2.6.27 kernel brings the ability to support external metadata arrays. External metadata implies that user space handles all updates to the metadata. The kernel's responsibility is to notify user space when a "metadata event" occurs, like disk failures and clean-to-dirty transitions. The kernel, in important cases, waits for user space to take action on these notifications. DESCRIPTION
Metadata updates: To service metadata update requests a daemon, mdmon, is introduced. Mdmon is tasked with polling the sysfs namespace looking for changes in array_state, sync_action, and per disk state attributes. When a change is detected it calls a per metadata type handler to make modifi- cations to the metadata. The following actions are taken: array_state - inactive Clear the dirty bit for the volume and let the array be stopped array_state - write pending Set the dirty bit for the array and then set array_state to active. Writes are blocked until userspace writes active. array_state - active-idle The safe mode timer has expired so set array state to clean to block writes to the array array_state - clean Clear the dirty bit for the volume array_state - read-only This is the initial state that all arrays start at. mdmon takes one of the three actions: 1/ Transition the array to read-auto keeping the dirty bit clear if the metadata handler determines that the array does not need resyncing or other modification 2/ Transition the array to active if the metadata handler determines a resync or some other manipulation is necessary 3/ Leave the array read-only if the volume is marked to not be monitored; for example, the metadata version has been set to "external:-dev/md127" instead of "external:/dev/md127" sync_action - resync-to-idle Notify the metadata handler that a resync may have completed. If a resync process is idled before it completes this event allows the metadata handler to checkpoint resync. sync_action - recover-to-idle A spare may have completed rebuilding so tell the metadata handler about the state of each disk. This is the metadata han- dler's opportunity to clear any "out-of-sync" bits and clear the volume's degraded status. If a recovery process is idled before it completes this event allows the metadata handler to checkpoint recovery. <disk>/state - faulty A disk failure kicks off a series of events. First, notify the metadata handler that a disk has failed, and then notify the kernel that it can unblock writes that were dependent on this disk. After unblocking the kernel this disk is set to be removed+ from the member array. Finally the disk is marked failed in all other member arrays in the container. + Note This behavior differs slightly from native MD arrays where removal is reserved for a mdadm --remove event. In the external metadata case the container holds the final reference on a block device and a mdadm --remove <container> <victim> call is still required. Containers: External metadata formats, like DDF, differ from the native MD metadata formats in that they define a set of disks and a series of sub- arrays within those disks. MD metadata in comparison defines a 1:1 relationship between a set of block devices and a raid array. For example to create 2 arrays at different raid levels on a single set of disks, MD metadata requires the disks be partitioned and then each array can created be created with a subset of those partitions. The supported external formats perform this disk carving internally. Container devices simply hold references to all member disks and allow tools like mdmon to determine which active arrays belong to which container. Some array management commands like disk removal and disk add are now only valid at the container level. Attempts to perform these actions on member arrays are blocked with error messages like: "mdadm: Cannot remove disks from a 'member' array, perform this operation on the parent container" Containers are identified in /proc/mdstat with a metadata version string "external:<metadata name>". Member devices are identified by "external:/<container device>/<member index>", or "external:-<container device>/<member index>" if the array is to remain readonly. OPTIONS
CONTAINER The container device to monitor. It can be a full path like /dev/md/container, a simple md device name like md127, or /proc/mdstat which tells mdmon to scan for containers and launch an mdmon instance for each one found. [NEWROOT] In order to support an external metadata raid array as the rootfs mdmon needs to be started in the initramfs environment. Once the initramfs environment mounts the final rootfs mdmon needs to be restarted in the new namespace. When NEWROOT is specified mdmon will terminate any mdmon instances that are running in the current namespace, chroot(2) to NEWROOT, and continue monitoring the con- tainer. Note that mdmon is automatically started by mdadm when needed and so does not need to be considered when working with RAID arrays. The only times it is run other that by mdadm is when the boot scripts need to restart it after mounting the new root filesystem. SEE ALSO
mdadm(8), md(4). v3.0.3 MDMON(8)
All times are GMT -4. The time now is 07:11 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy