Sponsored Content
Operating Systems Solaris "NO HARD Disks found" while installing Solaris 10 (latest-6/06) on Poweredge 2950. Post 302156948 by kayroreality on Wednesday 9th of January 2008 04:46:00 PM
Old 01-09-2008
Installed Solaris 10 8-07 x86 version on a Dell PowerEdge 2950 successfully

I called the Dell customer service folks and they emailed me the link to the correct driver and it worked!
Driver: MegaRAID SAS 8888ELP
OS: Solaris 10 8-07 x86 version
Platform: Dell Power Edge 2950 (6 x SAS 146 GB 10K drives)
Link to driver: MegaRAID SAS 8888ELP : MegaRAID SAS/SATA Feature Line : MegaRAID SAS/SATA : Internal RAID : Products : Storage : LSI

I downloaded the file HWR_SAS_Driver_SOLARIS_1.17.zip and unzipped it using WinRAR to get a file called components.tgz. Unzipped that file and got the file mega_sas.iso. I then used Nero to burn the image to disk.

Booted from the Solaris 10 DVD again and when I got to options 1-6: I chose option 5, update drivers. Chose c for cdrom/dvdrom, inserted the dvd and hit enter. After I hit enter I got the message:
CD in /dev/dsk/c2t0d0p0 does not contain driver updates
extracting software in /dev/dsk/c3t0d0p0
installing driver update in the miniroot
Insert media and enter media type:
Floppy [f], CD/DVD [c] or End [e]

At that point I entered e for end and then put back in the Solaris DVD and hit enter. It went back to the Solaris config screen after that and then followed the steps as usual. I didn't get that error from before: No Hard Disks found. Smilie
 

7 More Discussions You Might Find Interesting

1. Solaris

Installing Solaris 10 on Dell PowerEdge 2800

hi, i am trying to install solaris 10 (on 4 cd's downloaded from the sun website) on my dell poweredge 2800 server. 2 xeon processors, 2GB of RAM and 2 NICS, 73 GB SCSI (maxtor ultra320, 3.5 series), i can give more details on request... the installation crashes when trying to detect the NICS... (0 Replies)
Discussion started by: xinugeek
0 Replies

2. Solaris

Who has "Solaris 10 Advanced System Administration(SA-202-S10)" latest revision doc?

Dear All, I am going to examine SA202 but I got SA-202-S10 revision A.1 so it might be out of date. Who has "Solaris 10 Advanced System Administration(SA-202-S10)" latest revision document? Could you share it ? Thank you in advance (2 Replies)
Discussion started by: unitipon
2 Replies

3. Shell Programming and Scripting

awk command to replace ";" with "|" and ""|" at diferent places in line of file

Hi, I have line in input file as below: 3G_CENTRAL;INDONESIA_(M)_TELKOMSEL;SPECIAL_WORLD_GRP_7_FA_2_TELKOMSEL My expected output for line in the file must be : "1-Radon1-cMOC_deg"|"LDIndex"|"3G_CENTRAL|INDONESIA_(M)_TELKOMSEL"|LAST|"SPECIAL_WORLD_GRP_7_FA_2_TELKOMSEL" Can someone... (7 Replies)
Discussion started by: shis100
7 Replies

4. Solaris

Unknown Disks "offline or reservation conflict"

Hi All, I am a RH Linux admin that recently started working at a company with a number of SUN Servers so it's been an interesting transition. Considering the last person left with very little documentation left behind so I have been picking up most issues half complete, or troubleshot. ... (7 Replies)
Discussion started by: MobileGSP
7 Replies

5. Solaris

Printer configuration Migration from Solaris 10 "LP" to Solaris 11 "CUPS"

Need to find a way to import an LP printers.conf file to CUPS. I have some new Solaris 11.1 boxes that need to have 300 printers added. (0 Replies)
Discussion started by: os2mac
0 Replies

6. Solaris

Solaris 10 Sparc. How to change Vendor info of SAN disks reported in "format" command?

Greetings! After block level migration using an external appliance, the luns are getting reported as DGC-RAID5 and these luns are infact from the new storage. I have a query on changing the device Vendor info from DGC-RAID5 to HP3par in the format o/p only. AVAILABLE DISK SELECTIONS: ... (3 Replies)
Discussion started by: n_Bhaskar
3 Replies

7. Shell Programming and Scripting

Bash script - Print an ascii file using specific font "Latin Modern Mono 12" "regular" "9"

Hello. System : opensuse leap 42.3 I have a bash script that build a text file. I would like the last command doing : print_cmd -o page-left=43 -o page-right=22 -o page-top=28 -o page-bottom=43 -o font=LatinModernMono12:regular:9 some_file.txt where : print_cmd ::= some printing... (1 Reply)
Discussion started by: jcdole
1 Replies
AMR(4)                                                     BSD Kernel Interfaces Manual                                                     AMR(4)

NAME
amr -- MegaRAID SCSI/ATA/SATA RAID driver SYNOPSIS
To compile this driver into the kernel, place the following lines in your kernel configuration file: device pci device scbus device amr Alternatively, to load the driver as a module at boot time, place the following line in loader.conf(5): amr_load="YES" DESCRIPTION
The amr driver provides support for LSI Logic MegaRAID SCSI, ATA and SATA RAID controllers and legacy American Megatrends MegaRAID SCSI RAID controllers, including models relabeled and sold by Dell and Hewlett-Packard. LSI MegaRAID SAS controllers are supported by mfi(4) and will not work with this driver. HARDWARE
Controllers supported by the amr driver include: o MegaRAID SATA 150-4 o MegaRAID SATA 150-6 o MegaRAID SATA 300-4X o MegaRAID SATA 300-8X o MegaRAID SCSI 320-1E o MegaRAID SCSI 320-2E o MegaRAID SCSI 320-4E o MegaRAID SCSI 320-0X o MegaRAID SCSI 320-2X o MegaRAID SCSI 320-4X o MegaRAID SCSI 320-0 o MegaRAID SCSI 320-1 o MegaRAID SCSI 320-2 o MegaRAID SCSI 320-4 o MegaRAID Series 418 o MegaRAID i4 133 RAID o MegaRAID Elite 1500 (Series 467) o MegaRAID Elite 1600 (Series 493) o MegaRAID Elite 1650 (Series 4xx) o MegaRAID Enterprise 1200 (Series 428) o MegaRAID Enterprise 1300 (Series 434) o MegaRAID Enterprise 1400 (Series 438) o MegaRAID Enterprise 1500 (Series 467) o MegaRAID Enterprise 1600 (Series 471) o MegaRAID Express 100 (Series 466WS) o MegaRAID Express 200 (Series 466) o MegaRAID Express 300 (Series 490) o MegaRAID Express 500 (Series 475) o Dell PERC o Dell PERC 2/SC o Dell PERC 2/DC o Dell PERC 3/DCL o Dell PERC 3/QC o Dell PERC 4/DC o Dell PERC 4/IM o Dell PERC 4/SC o Dell PERC 4/Di o Dell PERC 4e/DC o Dell PERC 4e/Di o Dell PERC 4e/Si o Dell PERC 4ei o HP NetRAID-1/Si o HP NetRAID-3/Si (D4943A) o HP Embedded NetRAID o Intel RAID Controller SRCS16 o Intel RAID Controller SRCU42X DIAGNOSTICS
Driver initialisation/shutdown phase amr%d: memory window not available amr%d: I/O window not available The PCI BIOS did not allocate resources necessary for the correct operation of the controller. The driver cannot attach to this controller. amr%d: busmaster bit not set, enabling The PCI BIOS did not enable busmaster DMA, which is required for the correct operation of the controller. The driver has enabled this bit and initialisation will proceed. amr%d: can't allocate register window amr%d: can't allocate interrupt amr%d: can't set up interrupt amr%d: can't allocate parent DMA tag amr%d: can't allocate buffer DMA tag amr%d: can't allocate scatter/gather DMA tag amr%d: can't allocate s/g table amr%d: can't allocate mailbox tag amr%d: can't allocate mailbox memory A resource allocation error occurred while initialising the driver; initialisation has failed and the driver will not attach to this con- troller. amr%d: can't obtain configuration data from controller amr%d: can't obtain product data from controller The driver was unable to obtain vital configuration data from the controller. Initialisation has failed and the driver will not attach to this controller. amr%d: can't establish configuration hook amr%d: can't scan controller for drives The scan for logical drives managed by the controller failed. No drives will be attached. amr%d: device_add_child failed amr%d: bus_generic_attach returned %d Creation of the logical drive instances failed; attachment of one or more logical drives may have been aborted. amr%d: flushing cache... The controller cache is being flushed prior to shutdown or detach. Operational diagnostics amr%d: I/O beyond end of unit (%u,%d > %u) A partitioning error or disk corruption has caused an I/O request beyond the end of the logical drive. This may also occur if FlexRAID Vir- tual Sizing is enabled and an I/O operation is attempted on a portion of the virtual drive beyond the actual capacity available. amr%d: polled command timeout An initialisation command timed out. The initialisation process may fail as a result. amr%d: bad slot %d completed The controller reported completion of a command that the driver did not issue. This may result in data corruption, and suggests a hardware or firmware problem with the system or controller. amr%d: I/O error - %x An I/O error has occurred. SEE ALSO
cd(4), da(4), mfi(4), sa(4), scsi(4) AUTHORS
The amr driver was written by Mike Smith <msmith@FreeBSD.org>. This manual page was written by Mike Smith <msmith@FreeBSD.org> and Jeroen Ruigrok van der Werven <asmodai@FreeBSD.org>. BSD March 29, 2006 BSD