Top Forums Shell Programming and Scripting Help with script, shutdown if no ping responce Post 302156311 by Smiling Dragon on Monday 7th of January 2008 07:06:41 PM
Old 01-07-2008
Just to muddy the waters some more Smilie You should really consider pinging more than one thing before deciding to shutdown. Otherwise a router restart could shut down your server. Does your UPS have a network or serial port on it? It might be capable of sending a warning to the server directly in the event of a failure.
 

10 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

remote shutdown script

Dear all I would like to shutdown multiple servers remotely with the issue of one single command. What is the command to shut down a server remotely (ie, I want to issue a command on server X to shutdown server Y and server Z). Thank you (2 Replies)
Discussion started by: soliberus
2 Replies

2. UNIX for Advanced & Expert Users

Shutdown script

Hi Guys, I want to execute few of my bash script, so that whenever someone calls shutdown now -r command, I want my script to execute first before shutting down. Any help please????? I've just started playing with the unix system, so far its been brilliant.... (10 Replies)
Discussion started by: alpha_manic
10 Replies

3. Shell Programming and Scripting

Script not waiting for user responce

hi all, Im fairly new to scripting and am having a noobish issue. Ive got a script that checks for certain directories and if they dont exist, prompts the user to do a mkdir. heres trouble spot in the script: cat dirlsttemp.dat | while read dir; do echo "$dir does not exist, would you... (3 Replies)
Discussion started by: rdudejr
3 Replies

4. UNIX for Dummies Questions & Answers

A script for shutdown

I want to make a script to shutdown a unixware computer from other user then root. In Sco version i use "as root" but in the unixware i don't know. Please help me. 10x (12 Replies)
Discussion started by: kelu
12 Replies

5. HP-UX

Shutdown script

Hi, I am on Alpha Server with HP Tru64 system. I wish to setup shutdown to automatically and cleanly shutdown informix during the shutting down of the system. Ie. I was trying to use rc0.d to do this but failed. Has anyone tried doing this before? I already have the script and linked it to... (0 Replies)
Discussion started by: kingsto88
0 Replies

6. Shell Programming and Scripting

Script sh for shutdown

Hi, i need shutdown a pc, is in the same network what command i can use in the script :o ? (1 Reply)
Discussion started by: Dymblos
1 Replies

7. UNIX for Dummies Questions & Answers

Script to force Oracle database shutdown when shutdown immediate does not work

I have Oracle 9i R2 on AIX 5.2. My Database is running in shared server mode (MTS). Sometimes when I shutdown the database it shutsdown cleanly in 4-5 mints and sometimes it takes good 15-20 minutes and then I get some ora-600 errors and only way to shutdown is by opening another session and... (7 Replies)
Discussion started by: aixhp
7 Replies

8. Shell Programming and Scripting

Shutdown Script

Im writing a script to read a file called shutdown.cf and shut down any scripts that are listed there. I have came up with the following based on things I saw in similar programs but it doesn not work: Has anybody any idea what I may be doing wrong? Cheers Paul (4 Replies)
Discussion started by: runnerpaul
4 Replies

9. Shell Programming and Scripting

how to grep the responce on TL1

Hi All, I'm a newbie here.. how can i grep the data when i receive responce from TL1 example: responce from TL1: blabalbalbalbalba.,lbalba,SUCCESFULL,blahblahbalabh... how can i grep the "SUCCESSFULL" while i'm running the script? is it possible? because i'm only to know is if... (2 Replies)
Discussion started by: nikki1200
2 Replies

10. Shell Programming and Scripting

db shutdown script

I am going to create shutdown database script. We have dabase shutdown script. But i need take dabase which online and make it down. I got user id which needs to dabase to down ID=`ps -ef | grep -i pmon | grep -v grep | awk '{print $1}'` ( got orace side DB=`ps -ef | grep -i pmon |... (1 Reply)
Discussion started by: allwin
1 Replies
CLONE(8)							    NUT Manual								  CLONE(8)

NAME
clone - UPS driver clone NOTE
This man page only documents the specific features of the clone driver. For information about the core driver, see nutupsdrv(8). DESCRIPTION
This driver, which sits on top of another driver socket, allows users to group clients to a particular outlet of a device and deal with this output as if it was a normal UPS. EXTRA ARGUMENTS
This driver supports the following settings: load.off=command Recommended. Set the command on the "real" UPS driver that will be used to switch off the outlet. You need both load.off and load.on in order to power cycle the outlet. Otherwise, shutting down the clients powered by an outlet is a one way street (see IMPORTANT). load.on=command Recommended. Set the command on the "real" UPS driver that will be used to switch on the outlet. You need both load.off and load.on in order to power cycle the outlet. Otherwise, shutting down the clients powered by an outlet is a one way street (see IMPORTANT). load.status=value Recommended. Set the variable on the "real" UPS driver that will be used to indicate the outlet status (i.e. on/off). If not specified, the clone driver will attempt to keep track of the outlet status, but this is less reliable. offdelay=num Set the timer (in seconds) before the outlet is turned off after the shutdown condition (OB LB) for this outlet is met or a command to shutdown was issued. Defaults to 120 seconds. ondelay=num Set the timer (in seconds) for the outlet to switch on in case the power returns after the oulet has been switched off. Defaults to 30 seconds. mincharge=value Set the remaining battery level when the clone UPS switches to LB (percent). minruntime=value Set the remaining battery runtime when the clone UPS switches to LB (seconds). IMPLEMENTATION
The port specification in the ups.conf(5) reference the driver socket that the "real" UPS driver is using. For example: [realups] driver = usbhid-ups port = auto [clone-outlet-1] driver = clone port = usbhid-ups-realups load.on = outlet.1.load.on load.off = outlet.1.load.off load.status = outlet.1.status [...] IMPORTANT
Unlike a real UPS, you should not configure a upsmon master for this driver. When a upsmon master sees the OB LB flags and tells the upsd server it is OK to initiate the shutdown sequence, the server will latch the FSD status and it will not be possible to restart the systems connected without restarting the upsd server. This will be a problem if the power returns after the clone UPS initiated the shutdown sequence on it's outlet, but returns before the real UPS begins shutting down. The solution is in the clone driver, that will insert the FSD flag if needed without the help of a upsmon master. CAVEATS
The clone UPS will follow the status on the real UPS driver. You can only make the clone UPS shutdown earlier than the real UPS driver, not later. If the real UPS driver initiates a shutdown, the clone UPS driver will immediately follow. Be aware that the commands to shutdown/restart an outlet on the real UPS drivers are not affected, so if you tell the real UPS driver to shutdown the outlet of the clone UPS driver, your clients will lose power without warning. AUTHOR
Arjen de Korte <adkorte-guest@alioth.debian.org> SEE ALSO
upscmd(1), upsrw(1), ups.conf(5), nutupsdrv(8) Internet Resources: The NUT (Network UPS Tools) home page: http://www.networkupstools.org/ Network UPS Tools 05/21/2012 CLONE(8)
All times are GMT -4. The time now is 11:10 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy