Just to muddy the waters some more Smilie You should really consider pinging more than one thing before deciding to shutdown. Otherwise a router restart could shut down your server. Does your UPS have a network or serial port on it? It might be capable of sending a warning to the server directly in the event of a failure.
 

10 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

remote shutdown script

Dear all I would like to shutdown multiple servers remotely with the issue of one single command. What is the command to shut down a server remotely (ie, I want to issue a command on server X to shutdown server Y and server Z). Thank you (2 Replies)
Discussion started by: soliberus
2 Replies

2. UNIX for Advanced & Expert Users

Shutdown script

Hi Guys, I want to execute few of my bash script, so that whenever someone calls shutdown now -r command, I want my script to execute first before shutting down. Any help please????? I've just started playing with the unix system, so far its been brilliant.... (10 Replies)
Discussion started by: alpha_manic
10 Replies

3. Shell Programming and Scripting

Script not waiting for user responce

hi all, Im fairly new to scripting and am having a noobish issue. Ive got a script that checks for certain directories and if they dont exist, prompts the user to do a mkdir. heres trouble spot in the script: cat dirlsttemp.dat | while read dir; do echo "$dir does not exist, would you... (3 Replies)
Discussion started by: rdudejr
3 Replies

4. UNIX for Dummies Questions & Answers

A script for shutdown

I want to make a script to shutdown a unixware computer from other user then root. In Sco version i use "as root" but in the unixware i don't know. Please help me. 10x (12 Replies)
Discussion started by: kelu
12 Replies

5. HP-UX

Shutdown script

Hi, I am on Alpha Server with HP Tru64 system. I wish to setup shutdown to automatically and cleanly shutdown informix during the shutting down of the system. Ie. I was trying to use rc0.d to do this but failed. Has anyone tried doing this before? I already have the script and linked it to... (0 Replies)
Discussion started by: kingsto88
0 Replies

6. Shell Programming and Scripting

Script sh for shutdown

Hi, i need shutdown a pc, is in the same network what command i can use in the script :o ? (1 Reply)
Discussion started by: Dymblos
1 Replies

7. UNIX for Dummies Questions & Answers

Script to force Oracle database shutdown when shutdown immediate does not work

I have Oracle 9i R2 on AIX 5.2. My Database is running in shared server mode (MTS). Sometimes when I shutdown the database it shutsdown cleanly in 4-5 mints and sometimes it takes good 15-20 minutes and then I get some ora-600 errors and only way to shutdown is by opening another session and... (7 Replies)
Discussion started by: aixhp
7 Replies

8. Shell Programming and Scripting

Shutdown Script

Im writing a script to read a file called shutdown.cf and shut down any scripts that are listed there. I have came up with the following based on things I saw in similar programs but it doesn not work: Has anybody any idea what I may be doing wrong? Cheers Paul (4 Replies)
Discussion started by: runnerpaul
4 Replies

9. Shell Programming and Scripting

how to grep the responce on TL1

Hi All, I'm a newbie here.. how can i grep the data when i receive responce from TL1 example: responce from TL1: blabalbalbalbalba.,lbalba,SUCCESFULL,blahblahbalabh... how can i grep the "SUCCESSFULL" while i'm running the script? is it possible? because i'm only to know is if... (2 Replies)
Discussion started by: nikki1200
2 Replies

10. Shell Programming and Scripting

db shutdown script

I am going to create shutdown database script. We have dabase shutdown script. But i need take dabase which online and make it down. I got user id which needs to dabase to down ID=`ps -ef | grep -i pmon | grep -v grep | awk '{print $1}'` ( got orace side DB=`ps -ef | grep -i pmon |... (1 Reply)
Discussion started by: allwin
1 Replies
POWERD(8)						      System Manager's Manual							 POWERD(8)

NAME
powerd - UPS monitoring daemon SYNOPSIS
/sbin/powerd [tty] DESCRIPTION
powerd monitors the serial port connected to an UPS device and will perform an unattended shutdown of the system if the UPS is on battery longer than a specified number of minutes. powerd needs to watch a tty with modem control properties. Please refer to the powerd documen- tation for further information. powerd also has the capabilities of notifying other clients on the network that may have a UPS but not be connected to the serial line that there is a power outage, and id configured through the powerd.conf file CONFIGURATION FILE
Here is the configuration format: Lines beginning with '#' are ignored. MODE <mode> specifies the mode the UPS should be in. Valid arguements are MONITOR and PEER MONITOR being the mode to actually watch a UPS serial port, and PEER being to listen for a connection from a machine in MONITOR mode MONITOR <device> Specifies which device to monitor while in MONITOR mode. Specify an actual device file. Example: /dev/ttyS0 POWERFAIL <line> <high|low> Specifies which lines on the serial ports indicate that the power is out. Valid arguements are DCD, CAR, CTS, and RNG. Also specify if the line being HIGH or LOW indicates a power failure. Since most people may not know this arguement, Please use the enclosed upsdetect program to automatically find this line. NOTIFY <hostname[:port]> <password> Specified in MONITOR mode to notify a client running in PEER mode. Specify the hostname of the machine, and optional port the daemon is running on, And the password as specified by their LISTEN command. See below for more details. LISTEN <hostname> <password> Specified in PEER mode, specifies a hostname that is allowed to notify us of when the power is out, and the password they shall give us to authenticate themselves. The 2 passwords should match on the MONITOR mode machines NOTIFY password, and the PEER modes LISTEN password. LISTENPORT <port> Specified in PEER mode, specifies the port that powerd should listen on. If you use this arguement, powerd shall not default to using port 532, and the machine in MONITOR mode must specify the port you use in their NOTIFY command. DELAY <delayinseconds> Specifies how many seconds before notifying init of a power outage. Note that this doesnt mean that the system will shut down in that many seconds, as it depends on how init is configured. Init usually issues a 2 min shutdown. USER <username> Specifies which username to drop to from root. The program will reobtain root access only when it needs to, Like when notifying init that the power is out. This is simply a security feature, and not needed for powerd to operate. Note: powerd must still be run ini- tially as root. It will then drop to the user if, and only if, a username is specified. ARGUMENTS
None: Please use the configuration file /etc/powerd.conf which can be generated with detectups. See detectups(8) for more information FILES
/etc/powerd.conf powerd configuration file /etc/powerstatus indicates line power status /etc/inittab init is what actually issues the shutdown SEE ALSO
powerd(8), shutdown(8), wall(1), init(8), inittab(5). AUTHOR
James Brents <James@nistix.com> (with parts of this man page borrowed from all over the Linux community) POWERD(8)
All times are GMT -4. The time now is 09:37 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy