Sponsored Content
Operating Systems HP-UX Break mirror so that it can be used later Post 302140106 by AQG on Wednesday 10th of October 2007 09:03:07 PM
Old 10-10-2007
Thanks for your help caiser!!!!
helped a lot.
 

9 More Discussions You Might Find Interesting

1. Solaris

patch update and break mirror

Hi All, How do you know if you need to break the mirror on solaris 8 patch update? Here's the patch example, 117350-54. On the site, it's just a low type update and not a medium or critical. Is breaking a mirror a best practice only or really a requirement to some patch? Thanks, itik (1 Reply)
Discussion started by: itik
1 Replies

2. Solaris

break solaris mirror

Hi All, How do I break the solaris 8 mirror? And how do I make sure I will point the first hd mirror on reboot. If the first break mirror won't boot. How do I make the copy mirror to boot? Thanks in advance, itik (2 Replies)
Discussion started by: itik
2 Replies

3. Solaris

ZFS Mirror versus Hardware Mirror

I've looked a little but haven't found a solid answer, assuming there is one. What's better, hardware mirroring or ZFS mirroring? Common practice for us was to use the raid controllers on the Sun x86 servers. Now we've been using ZFS mirroring since U6. Any performance difference? Any other... (3 Replies)
Discussion started by: Lespaul20
3 Replies

4. Solaris

What is mirror and sub mirror in RAID -1 SVM

Hi , I am new to SVM .when i try to learn RAID 1 , first they are creating two RAID 0 strips through metainit d51 1 1 c0t0d0s2 metainit d52 1 1 c1t0d0s2 In the next step metainit d50 -m d51 d50: Mirror is setup next step is metaattach d50 d52 d50 : submirror d52 is... (7 Replies)
Discussion started by: vr_mari
7 Replies

5. Solaris

Solaris Volume Manager: Break Mirror and use to make a 2nd machine

Hello: I have a machine built on 2 drives and mirrors have been created to a second set of 2 drives (4 total) on the same platform. SVM. Might anyone provide guidance to create a second machine by breaking the mirrored set, moving the two mirrors (2) to another machine (same platform type),... (1 Reply)
Discussion started by: 4dailyrunner
1 Replies

6. Shell Programming and Scripting

BASH: Break line, read, break again, read again...

...when the lines use both a colon and commas to separate the parts you want read as information. The first version of this script used cut and other non-Bash-builtins, frequently, which made it nice and zippy with little more than average processor load in GNOME Terminal but, predictably, slow... (2 Replies)
Discussion started by: SilversleevesX
2 Replies

7. Linux

LVM - break mirror taking out orignal copy

Hi Guys, I have a mirrored LVM volume, and wish to break the mirror leaving only copy1 (effectively removing copy 0). Here's the config: # lvs -a -o +devices lvdata vg01 mwi-ao 2.19T lvdata_mlog 100.00 lvdata_mimage_0(0),lvdata_mimage_1(0) vg01... (0 Replies)
Discussion started by: badoshi
0 Replies

8. HP-UX

What is the difference between DRD and Root Mirror Disk using LVM mirror ?

what is the difference between DRD and Root Mirror Disk using LVM mirror ? (3 Replies)
Discussion started by: maxim42
3 Replies

9. AIX

AIX break rootvg mirror from system down

Hello, aix 5.2, mirrored rootvg on hdisk0 and hdisk1. hdisk0 is dead. I can boot to cd, into sms, into maintenance mode. I can fsck all the various partitions on hdisk1 (the hd4 hd2 hd3, etc...) all is fine. But without the hdisk0 part of the mirror I cannot get the system to boot. ystem hangs on... (6 Replies)
Discussion started by: sshapiro
6 Replies
pbmreduce(1)						      General Commands Manual						      pbmreduce(1)

NAME
pbmreduce - read a portable bitmap and reduce it N times SYNOPSIS
pbmreduce [-floyd|-fs|-threshold ] [-value val] N [pbmfile] DESCRIPTION
Reads a portable bitmap as input. Reduces it by a factor of N, and produces a portable bitmap as output. pbmreduce duplicates a lot of the functionality of pgmtopbm; you could do something like pnmscale | pgmtopbm, but pbmreduce is a lot faster. pbmreduce can be used to "re-halftone" an image. Let's say you have a scanner that only produces black&white, not grayscale, and it does a terrible job of halftoning (most b&w scanners fit this description). One way to fix the halftoning is to scan at the highest possible res- olution, say 300 dpi, and then reduce by a factor of three or so using pbmreduce. You can even correct the brightness of an image, by using the -value flag. OPTIONS
By default, the halftoning after the reduction is done via boustrophedonic Floyd-Steinberg error diffusion; however, the -threshold flag can be used to specify simple thresholding. This gives better results when reducing line drawings. The -value flag alters the thresholding value for all quantizations. It should be a real number between 0 and 1. Above 0.5 means darker images; below 0.5 means lighter. All flags can be abbreviated to their shortest unique prefix. SEE ALSO
pnmenlarge(1), pnmscale(1), pgmtopbm(1), pbm(5) AUTHOR
Copyright (C) 1988 by Jef Poskanzer. 02 August 1989 pbmreduce(1)
All times are GMT -4. The time now is 03:29 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.