Sponsored Content
Top Forums Shell Programming and Scripting how to trap unix signal if the process killed/interupt occured in bash... Post 302137156 by manas_ranjan on Sunday 23rd of September 2007 04:32:08 AM
Old 09-23-2007
hey buddies, thanx a lot....
i found the problem, the thing is TRAP is not yet installed...in my box...

i need further assistance from your end, i.e.
1 I would like to install the TRAP in my box,
>The steps, from where should i get the utility, and instruction
manual from your side........can i get it ????

2 This question is the silly one, but >how to know which version of
bash i am working ????


Kindly assist ....
 

10 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

Fmli Signal/trap

Does anyone know how to program signals in fmli? My fmli script goes in loop when the telnet session is closed. When I start the script from the prompt the issue do not happen. But when it is started by the login process it hags. That's why I want to program the SIGHUP to exit/finish the script.... (0 Replies)
Discussion started by: Marcos Brito
0 Replies

2. Shell Programming and Scripting

trap signal for enter key

hi , What is the trap signal for "ENTER key"? (4 Replies)
Discussion started by: Sreejith_VK
4 Replies

3. UNIX for Dummies Questions & Answers

trap signal on user logout ?

hi all , I want to execute a script on the user logout(using gnome environment). Is ther any way to execute it through TRAP stmt? (2 Replies)
Discussion started by: harsha10
2 Replies

4. Shell Programming and Scripting

Killed by signal 15.

Hi all I have Master script, Main script ,and 4 Child script. Master.sh #!/bin/bash /export/home/user/Main.shMain.sh #!/bin/bash /export/home/user/Child1.sh & /export/home/user/Child2.sh & /export/home/user/Child3.sh & /export/home/user/Child4.sh &I run only Master.sh script... (1 Reply)
Discussion started by: almanto
1 Replies

5. Shell Programming and Scripting

How to Trap kill -9 signal

I just want to trap kill -9 signal issued by any of user from any terminal and just capture that user terminal who had raised this kill -9 command (1 Reply)
Discussion started by: puneet.goel
1 Replies

6. Shell Programming and Scripting

Record the Signal Type or Number in Bash Trap function

In my Bash script I have an exit/cleanup function in a trap statement like: trap exitCleanup 1 2 3 6 15 25 Is there anyway to capture which signal # has occurred to record in a log file. Please note I am trying to avoid something like: trap 'mySignal=1; exitCleanup' 1 trap... (1 Reply)
Discussion started by: ckmehta
1 Replies

7. Shell Programming and Scripting

How trap a signal in shell script?

Hi , i have a scenario where...i have to put a check where if script is executing more than 15mins i have to kill that script and n retry again 2nd time. i this case i can use background process to do it but i feel trap will be the efficent way to do so... but i dont know much about it... (1 Reply)
Discussion started by: crackthehit007
1 Replies

8. Linux

Problem with dovecot (Killed with signal 15)

hey, i have been facing a very fatel error with dovecot.. i am getting this error in my dovecot.log file dovecot: Feb 13 15:21:02 Fatal: chdir(/var/mail/folders/user1) failed with uid 1001: Permission denied dovecot: Feb 13 15:21:02 Error: child 18732 (imap) returned error 89 dovecot: Feb... (3 Replies)
Discussion started by: htshshrm2
3 Replies

9. Shell Programming and Scripting

Quiting running process without catching TRAP signal

Hi, I would like to ask, if is it possible to quit running loop in the script any other way than catching the trap signal. Ctrl-C ends only current running instance of process but not whole script. Any clues? (3 Replies)
Discussion started by: smoofy
3 Replies

10. Shell Programming and Scripting

Crashing machins at ESXI-6 killed by TERM signal

Hi, i have 2 machines in ESXI6 that both made a restart at the same time but no errors from ESXI side. one machine with Centos 6.6 and one with centos 7 same log at the Dmesg: please help me find a lead what could made this ? Mar 17 20:20:28 pbxnl-b-sales-ru-ua init: tty (/dev/tty1) main... (2 Replies)
Discussion started by: batchenr
2 Replies
kill(2) 							System Calls Manual							   kill(2)

Name
       kill - send signal to a process

Syntax
       #include <sys/types.h>
       #include <signal.h>

       kill(pid, sig)
       pid_t pid;
       int sig;

Description
       The  system  call sends the signal sig to a process specified by the process number pid.  The sig can be a signal specified in a call or it
       can be 0.  If the sig is 0, error checking is performed, but a signal is not sent.  This call can be used to check the validity of pid.

       The sending and receiving processes must have the same effective user ID, otherwise this call is  restricted  to  the  superuser  with  the
       exception of the signal SIGCONT.  The signal SIGCONT can always be sent to a child or grandchild of the current process.

       If the process number is 0, the signal is sent to all other processes in the sender's process group.

       If  the process number is negative but not -1, the signal is sent to all processes whose process-group-id is equal to the absolute value of
       the process number.

       The above two options are variants of

       If the process number is -1, and the user is the superuser, the signal is broadcast for all processes except to system  processes  and  the
       process sending the signal.

       Processes may send signals to themselves.

Environment
       System Five
       POSIX

       When  your  program  is	compiled in the System V or POSIX environment, a signal is sent if either the real or effective uid of the sending
       process matches the real or saved-set-uid (as described in ) of the receiving process. In addition, any process can use a pid  of  -1,  and
       the signal is sent to all processes subject to these permission checks.

       In POSIX mode, the pid argument is of type pid_t.

Return Values
       Upon successful completion, a value of 0 is returned.  Otherwise, a value of -1 is returned, and is set to indicate the error.

Diagnostics
       The system call fails under the following conditions:

       [EINVAL]       The sig is not a valid signal number.

       [EPERM]	      The  sending  process  is not the superuser, and its effective user ID does not match the effective user ID of the receiving
		      process.

       [ESRCH]	      No process can be found corresponding to that specified by pid.

See Also
       execve(2), getpgrp(2), getpid(2), killpg(2), sigvec(2), pause(3)

																	   kill(2)
All times are GMT -4. The time now is 03:47 AM.