Sponsored Content
The Lounge What is on Your Mind? How Many Technology Forums Do You Actively Participate In? Post 302129539 by zazzybob on Tuesday 31st of July 2007 11:35:09 AM
Old 07-31-2007
Same here - just UNIX.COM. I've tried others, but have generally been unimpressed by their content, and their lack of proper moderation (i.e. high noise ratio).

Cheers,
ZB
 

6 More Discussions You Might Find Interesting

1. Shell Programming and Scripting

Actively watching for running processes

Here's a fun one... What's the best way to script looking for a process when it runs? For example, what if a process is running that's been set up graphically, which you would like the entire command line string for? Say it's rpm for the sake of having a command to use as an example. You want... (2 Replies)
Discussion started by: sysera
2 Replies

2. HP-UX

how to check whether a script is running actively or hanged/ in deadlock)

Hi I have a doubt regarding process states in HP unix system. Is there a way to check whether a process is hanged or still actively running? I have few scripts which run for a long time. but sometimes these are getting hanged. But i'm never sure whether they are running or waiting in kind of... (4 Replies)
Discussion started by: truth
4 Replies

3. AIX

How to determine what process is actively using my harddisk?

Hi, Is there any command that I can issue to check who is actively using my harddisk? I notice that yesterday the hdisk0 and hdisk1 is really actively being used and is reaching almost 100%. I realized that this is because of paging which is climbing up to 70%. However, just this morning... (3 Replies)
Discussion started by: depam
3 Replies

4. AIX

unix host actively refused the connection attempt

Dear all, I am faced with an error "UX ER087-0" failling to connect to the server. Any ideas of what might be causing the error? Many thanks (17 Replies)
Discussion started by: captain.scorpio
17 Replies

5. Shell Programming and Scripting

Actively merge kde 3.x and gnome 2.x menus

ok, here's the scoop, google has similar, but nothing that quite fits the bill. here is what I'm up against: i have a linux system that is running both kde 3.x and gnome 2.x, selectable via gdm. the kde 3.x app menu is heavily modified and i'm looking for a way to import that over to the... (0 Replies)
Discussion started by: macphail
0 Replies

6. What is on Your Mind?

Regarding thoughts for encourage more users to post/participate on UNIX.com site.

Hello All, Greetings!! Have a thought about how could we encourage more users to post and participate more on UNIX.com(because more we get questions, more we learn more), few are my ideas which I am posting feel free to add/edit more ideas in here. Keeping this as a POLL too. I- Allow... (10 Replies)
Discussion started by: RavinderSingh13
10 Replies
JNOISEMETER(1)						      General Commands Manual						    JNOISEMETER(1)

NAME
jnoisemeter - Jnoisemeter is a small app which measure audio test signals. SYNOPSIS
jnoisemeter [options] DESCRIPTION
This manual page documents briefly the jnoisemeter This manual page was written for the Debian distribution because the original program does not have a manual page. jnoisemeter is a small app designed to measure audio test signals and in particular noise signals through Jack Audio Connection Kit. The simplest use is to measure the S/N ratio of your sound card. If you can calibrate the input levels of your soundcard it can also be used (with some external hardware) to measure noise levels of any type of audio equipment, including preamps and microphones. jnoisemeter has the following filters: FLAT No filtering at all, the signal is passed directly to the detector. 20KHZ This is 4th order Chebyshev lowpass filter having a noise bandwidth of exactly 20 kHz. This means that if the input signal is white noise, the RMS output level is the same as for a 'perfect' 20 kHz lowpass filter. This is the normal filter to use for 'unweighted' measurements, as any noise measurement should always use a well-defined bandwidth. Future version may use a higher order filter. IEC A and C The well-known standard noise weighting filters used to obtain dB(A) and dB(C) measurements. ITU-R468 This is a filter optimised for measuring low-level background noise. It rises 6 dB/oct at low frequencies, has a peak of around +12 dB at 6.3 kHz, and falls off radiply after that. It should be used together with the ITU-R468 detector described below. ITU-R468 (Dolby variant) This is the same filter as the previous one with around 5.6 dB less gain. See below for why this exists. jnoisemeter also provides a DC blocking filter (first order highpass, 5 Hz). This may be necessary when using the FLAT and 20KHZ filters, the others are DC-blocking anyway. jnoisemeter has three detectors: RMS Root-mean-square (i.e. 'power') meter. The time constant is 125 ms as per IEC standard, or 1 second in slow mode. AVERAGE This measures the average of the absolute value. The one used in jnoisemeter is actually a VU meter. A 10 times slower version is also provided. ITU-R468 This is a 'pseudo-peak' detector designed specifically to measure noise and S/N ratios. For a peak meter it is quite slow, as it should be for noise measurements, but at the same time it is much more sensitive to short impulsive noise than its speed would suggest. The original rationale for this was the presence of impulsive noise (generated by the electromechanical telephone exchanges of those days) on long analog audio lines. Today long distance audio lines are all digital, but a detector such as this one is also ideal to reveal the typical short noise bursts and 'crackle' originating in computers and other digital equipment. All three detectors will show 0.0 dB for a 'digital full scale' sine wave (i.e. peaking +/- 1.0). The ITU-R468 standard This uses both the ITU filter and detector, and is probably the 'best' standardized way to measure noise. It is used by e.g. the manufac- turers of quality microphones, in particular the European ones. It produces a result that is on average about 10 dB higher than an A- weighted RMS measurement. There is a 'variation' of this standard called 'ITU-ARM'. This was devised by Dolby Inc. at the time they were selling noise reduction technology for magnetic tape recorders. The traditional A-weighted measurements would show very little S/N ratio improvement when using Dolby-B. For this reason Dolby wanted to adopt the ITU-R468 method (which shows the difference quite clearly) but without the apparent 10 dB loss in S/N ratio as this was deemed bad for marketing. The solution adopted was to lower the gain of the filter, and use an average detector instead of the pseudo-peak one. Despite the 'ITU-ARM' name this is not an official standard, and not approved by the ITU. OPTIONS
-h Display short info -n <name> Name to use as jack client SEE ALSO jackd(1). AUTHOR
jnoisemeter was written by Fons Adriaensen <fons@kokkinizita.net>. This manual page was written by Jaromir Mike <mira.mikes@seznam.cz> for the Debian project (but may be used by others). August 2, 2010 JNOISEMETER(1)
All times are GMT -4. The time now is 05:21 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy